• Title/Summary/Keyword: high-low junction

Search Result 267, Processing Time 0.025 seconds

Enhancement of Photovoltaic Performance of Fluorescence Materials added TiO2 electrode in Dye-sensitized Solar Cells (형광물질을 이용한 염료감응태양전지의 효율향상)

  • Cheon, JongHun;Lee, JeongGwan;Jung, MiRan;Kim, JaeHong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.88.2-88.2
    • /
    • 2010
  • Dye-sensitized solar cells (DSSCs) have attracted considerable attention on account of their high solar energy-to-conversion efficiencies and low cost processes compared to conventional p-n junction solar cells. The mechanism of DSSC is based on the injection of electrons from the photo excited dyes into the conduction band of the semiconductor electrode. The oxidized dye is reduced by the hole injection into either the hole conductor or the electrolyte. Thus, the light harvesting effect of dye plays an important role in capturing the photons and generating the electron/hole pair, as well as transferring them to the interface of the semiconductor and the electrolyte, respectively. We used the organic fluorescence materials which can absorb short wavelength light and emit longer wavelength region where dye sensitize effectively. In this work, the DSSCs were fabricated with fluorescence materials added $TiO_2$ photo-electrode which were sensitized with metal-free organic dyes. The photovoltaic performances of fluorescence aided DSSCs were compared, and the recombination dark current curves and the incident photon-to-current (IPCE) efficiencies were measured in order to characterize the effects of the additional light harvesting effect in DSSC. Electro-optical measurements were also used to optimize the fluorescence material contents on TiO2 photo-electrode surface for higher conversion efficiency (${\eta}$), fill factor (FF), open-circuit voltage (VOC) and short-circuit current (ISC). The enhanced light harvesting effect by the judicious choice/design of the fluorescence materials and sensitizing dyes permits the enhancement of photovoltaic performance of DSSC.

  • PDF

Development of a Height Adjustment Method of Prefabricated Individual Footing for the Leveling of Unit Modular Structural System (유닛모듈러 건축구조물의 수평 정밀도 확보를 위한 Pre-Fab 독립기초 높이조절 공법 개발)

  • Jun, Young-hun;Kim, Kyoon-Tai;Chae, Myung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.631-639
    • /
    • 2015
  • In the unit modular construction, the unit module prefabricated in a factory with a high level of accuracy does not fit completely onto the ground-joint junction due to the low accuracy of the ground work. This difference in the level of accuracy can cause diverse problems, such as twisting the upper unit modules and loosening the connection between the module and the footing. On this background, the aim of this study is to develop a technique for adjusting the height of the prefabricated individual footing. To accomplish the aim, a height adjustment method using bolts and nuts is proposed, and a shop drawing and the construction sequence are also presented in this study. The structural safety is verified through a structure simulation. In the future, research will be conducted on a mock-up test of the height adjustment method developed in this study, and an analysis of economic feasibility will be performed in order to verify its constructability and usability.

A Study on the Use of 10 MV X-Ray with Lead Absorber for Treatment of Head and Neck Tumors (10MV X선(線)을 이용(利用)한 경부(頸部) 방사선(放射線) 치료시(治療時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kim, Hyung Sik;Kang, Wee Saing;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.25-28
    • /
    • 1983
  • Anterior and posterior parallel opposed field technique covering entire neck is desirable for elimination of junctional problems in treating upper neck with bilateral parallel opposed fields and lower neck with anterior one field. For good dose distribution in neck, dose in build-up region should be high for anterior field and should be low for posterior field. And so, with 10 MV X-ray, lead absorber was used for anterior field only. The adequate thickness of lead absorber, absorber-skin separation, width of central cord block for posterior field and anterior & posterior field weight were studied using film dosimery. The results are as follows. 1. As the thickness of the lead absorber increased the dose in build-up region increased. 2. As the absorber-skin separation decreased the dose in build-up region increased. 3. The adequate thickness of lead absorber was around 5.6mm. 4. The adequate absorber-skin separation was around 5cm. 5. The adequate posterior cord block width was 3cm. 6. 4:1 weighting for anterior and posterior field was adequate. And so with this technique, adequate dose distribution could be made as well as elimination junction problems.

  • PDF

Electron Emission Properties of Hetero-Junction Structured Carbon Nanotube Microtips Coated With BN And CN Thin Films (탄소 나노튜브 위에 붕소 및 탄소 질화 박막이 코팅된 이종접합 구조 미세팁의 전자방출 특성)

  • Noh, Young-Rok;Kim, Jong-Pil;Park, Jin-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.743-748
    • /
    • 2010
  • Boron nitride (BN) and carbon nitride (CN) films, which have relatively low work functions and commonly exhibit negative electron affinity behaviors, were coated on carbon nanotubes (CNTs) by magnetron sputtering. The CNTs were directly grown on metal-tip (tungsten, approximately 500nm in diameter at the summit part) substrates by inductively coupled plasma-chemical vapor deposition (ICP-CVD). The variations in the morphology and microstructure of CNTs due to coating of the BN and CN films were analyzed by field-emission scanning electron microscopy (FE-SEM). The energy dispersive x-ray (EDX) spectroscopy and Raman spectroscopy were used to identify the existence of the coated layers (CN and BN) on CNTs. The electron-emission properties of the BN-coated and CN-coated CNT-emitters were characterized using a high-vacuum field emission measurement system, in terms of their maximum emission currents ($I_{max}$) at 1kV and turn-on voltage ($V_{on}$) for approaching $1{\mu}A$. The results showed that the $I_{max}$ current was significantly increased and the $V_{on}$ voltage were remarkably reduced by the coating of CN or BN films. The measured values of $I_{max}-V_{on}$ were as follows; $176{\mu}A$-500V for the 5nm CN-coated emitter and $289{\mu}A$-540V for the 2nm BN-coated emitter, respectively, while the $I_{max}-V_{on}$ of the as-grown (i.e., uncoated) emitter was $134{\mu}A$-620V. In addition, the CNT emitters coated with thin CN or BN films also showed much better long-term (up to 25h) stability behaviors in electron emission, as compared with the conventional CNT emitter.

A Study on Ka band Qualification Model Multiplexers for Communication, Ocean and Meteorological Satellite (COMS) Payload (통신해양기상위성 Ka 대역 인증모델 밀티플렉서에 대한 연구)

  • Eom, Man-Seok;An, Gi-Beom;Yun, So-Hyeon;Gwak, Chang-Su;Yeom, In-Bok
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.2
    • /
    • pp.63-70
    • /
    • 2006
  • This paper presents the results of Ka band qualification model multiplexers for COMS Payload to be launched in 2008. These are the input and output multiplexers of the satellite transponder to use available frequency resources effectively and the diplexer of the satellite antenna to use the same reflector for both transmitting and receiving frequency bands, respectively. The input multiplexer with four frequency channels has four(4) independent channel filters which consist of an 8-pole elliptic band-pass filter for high frequency selectivity and a 2-pole equalizer for group delay equalization. For low insertion loss, mass and volume reduction, manifold type os employed for output multiplexer. E-plane T-junction is used for either splitting or combining a frequency band into two sub-bands. Asymmetric inductive irises are used to tune the receiving filter easily. The electrical performance and environmental test such as vibration test, mechanical shock test, thermal vacuum test and EMC test are performed and the results of all qualification model multiplexers are compliant to the requirement of each multiplexer. Followed by this qualification, the flight model equipment will be developed.

  • PDF

An Experimental Study on the Heat Transfer Characteristics of the Conversion Efficiency in the Concentrated Photovoltaic Cells (방열 특성에 따른 집광형 태양전지의 광전변환효율 변화에 관한 실험적 연구)

  • Kim, Kangho;Jung, Sang Hyun;Kim, Youngjo;Kim, Chang Zoo;Jun, Dong Hwan;Shin, Hyun-Beom;Lee, Jaejin;Kang, Ho Kwan
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.168-172
    • /
    • 2014
  • Under concentrated illuminations, the solar cells show higher efficiencies mainly due to an increase of the open circuit voltage. In this study, InGaP/InGaAs/Ge triple-junction solar cells have been grown by a low pressure metalorganic chemical vapor deposition. Photovoltaic characteristics of the fabricated solar cells are investigated with a class A solar simulator under concentrated illuminations from 1 to 100 suns. Ideally, the open circuit voltage should increase with the current level when maintained at the same temperature. However, the fabricated solar cells show degraded open circuit voltages under high concentrations around 100 suns. This means that the heat sink design is not optimized to keep the cell temperature at $25^{\circ}C$. To demonstrate the thermal degradation, changes of the device performance are investigated with different bonding conditions and heat sink materials.

Analysis of Clip-induced Ischemic Complication of Anterior Choroidal Artery Aneurysms

  • Cho, Min-Soo;Kim, Min-Su;Chang, Chul-Hoon;Kim, Sang-Woo;Kim, Seong-Ho;Choi, Byung-Yon
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.3
    • /
    • pp.131-134
    • /
    • 2008
  • Objective: The surgical approach for anterior choroidal artery (AChA) aneurysm is typically similar to those used for other supraclinoid internal carotid artery (ICA) lesions. However, the surgical clipping of this aneurysm is complicated and as a result. can result in postoperative ischemic complications. The purpose of this study was to clarify the risk of clip-induced ischemic complication in AChA aneurysm and to get the benefits for helping decision making. Methods: We retrospectively investigated 53 cases (4.0%) of AchA aneurysm treated surgically. We divided the AChA aneurysm to 3 subtype according to the origin of aneurysmal neck; A type originating from the AChA itself. J type from junction of AChA and ICA and I type from the ICA itself. We evaluated brain CT about 1 week post-operative day to confirm the low density in AChA territory. Results: Ruptured aneurysm was 26 cases and unruptured aneurysm 27 cases. The aneurysmal subtype of A, J, and I was 13, 17, and 23 cases. Of the 53 cases who performed surgical neck clipping, twelve (22.6%) had postoperative AChA distribution infarcts. Increased infarct after neck clipping had statistic significance in non-I subtype (r=0.005) Conclusion: AChA aneurysm surgery carries a significant risk of postoperative stroke. Don't always stick to clipping only, especially in non-I type of incidental small aneurysm, which has high risk of post-clip ischemic complications.

Development of a CAN-based Real-time Simulator for Car Body Control

  • Kang, Ki-Ho;Seong, Sang-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.444-448
    • /
    • 2005
  • This paper presents a developing procedure of the CAN-based real-time simulator for car body control, aiming at replacing the actual W/H (Wiring Harness) and J/B(Junction Box) couple eventually. The CAN protocol, as one kind of field-bus communication, defines the lowest 2 layers of the ISO/OSI standard, namely, the physical layer(PL) and the data link layer(DLL), for which the CSMA/NBA protocol is generally adopted. For CPU, two PIC18Fxx8x's are used because of their built-in integration of CAN controller, large internal FLASH memory (48K or 64K), and their costs. To control J/B's and actuators, 2 controller boards are separately implemented, between which CAN lines communicate through CAN transceivers MCP255. A power motor for washing windshield, 1 door lock motor, and 6 blink lamps are chosen for actuators of the simulator for the first stage. For the software architecture, a polling method is used for the fast global response time despite its slow individual response time. To improve the individual response time and to escape from some eventual trapped-function loops, High/Low ports of the CPU are simply used, which increases the stability of the actuator modules. The experimental test shows generally satisfactory results in normal transmitting / receiving function and message trace function. This simulator based on CAN shows a promising usefulness of lighter, more reliable and intelligent distributed body control approach than the conventional W/H and J/B couple. Another advantage of this approach lies in the distributed control itself, which gives better performance in hard real-time computing than centralized one, and in the ability of integrating different modules through CAN.

  • PDF

Characteristics of Pollutant Concentration from Livestock Wastewater Effluent Combined with Stormwater Runoff (강우시 및 건기시 축산지역에서 배출되는 오염물질의 유출특성 비교)

  • Tobio, Jevelyn Ann S.;Maniquiz-Redillas, Marla C.;Lee, Yuwha;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.896-901
    • /
    • 2012
  • In this research, the levels of concentrations from the junction of effluent from wastewater treatment plant during dry days and combined with runoff from the surrounding 11 ha livestock catchment area during wet days were determined to investigate the relationships of the concentration of various pollutants such as particulates, nutrients and organics originating from point and nonpoint sources. Manual sampling was conducted from October 2008 to December 2011 during dry and wet days. Based on the results, the flow rates and concentrations of most pollutant parameters were increased during wet days. It was found out that the effluent wastewater combined with stormwater runoff has low BOD to TN/TP ratio and high TN/TP to BOD ratio. Therefore, it is needed to employ other treatment methods to effectively manage the wastewater and reduce the pollutant discharge to receiving water bodies.

Autologous Cartilage Intracordal Injection in Unilateral Vocal Fold Paralysis

  • Wang, Soo-Geun;Lee, Byung-Joo;Goh, Eui-Kyung;Chon, Kyon-Myong;Roh, Hwan-Jung;Lee, Jin-Choon
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.182-182
    • /
    • 2003
  • Objectives : The methods to treat glottic incompetence include thyroplasty type I, arytenoid abduction, and intracordal injection using various materials. The intracordal injection is easy and simple and does not require skin incision. In general, the grafted cartilage shows a high survival rate, a low absorption rate and small voluminous change. The authors performed injection of minced autologous auricular cartilage and fat using a Bruning injector in unilateral vocal cord palsy We evaluate the effect and safety of autologous auricular cartilage intracordal injection. Study Design : Retrospective study. Methods : Auricular cartilage was obtained by incising tragus vertically and it was minced with a scalpel and #15 blade. About 2g of abdominal fat was obtained by small periumbrical incision and cut into small pieces. The minced cartilage was put into a 1$m\ell$ injector and then the injector was filled with fat. The operation was conducted under laryngeal microscope. Minced cartilage was injected into the vocalis muscle at the junction of the middle and posterior third of the vocal fold. In three cases, we performed autologous cartilage intracordal injection. Results : We observed no postoperative complications, such as dyspnea, granulation, inflammation, in any of the cases. The voice was improved compared with the voice prior to operation in all cases. Conclusion : Although the cases are still limited and the observation period is short, we suggest that the autologous cartilage using the auricular cartilage is the ideal and new effective augmentative material in vocal cord palsy.

  • PDF