• Title/Summary/Keyword: high-intensity ultrasound

Search Result 94, Processing Time 0.029 seconds

Optimal Processing Parameters of Low Molecular Weight Carrageenan by Ultrasound (초음파에 의한 carrageenan 저분자화의 최적 조건)

  • KIM Sang-Moo;PARK Seong-Min;CHOI Hyeon-Mee;LEE Keun-Tai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.4
    • /
    • pp.495-500
    • /
    • 1999
  • The carrageenans are linear, sulfated Polysaccharides extracted from various species of the Rhodophyta (marine red algae). The carrageenan backbone is based on a repeating disaccharide sequence of $\beta$-D-galactopyranose residues linked glycosidically through position 1 and 3, and $\alpha$-D-galactopyranose residues linked glycosidically through position 1 and 4. Carrageenans are typical food polysaccharides in that food applications overwhelmingly dominate their end uses. Other applications, hewer, including cosmetics, pharmaceuticals, industrial suspensions and paints are also of importance But because of its high degree of gelling and viscosity with low solubility, carrageenan is limited to use beyond $0.03\%$ as food additives. Response Surface Methodology was applied for optimizing the processing parameters of ultrasound treatment in order to produce low-molecular-weight carrageenan. The use of ultrasound significantly reduced viscosity of $\lambda$-carrageenan solutions. Optimal parameters for ultrasound reduction of carrageenan molecular weight were: temperature, $10^{\circ}C$; ultrasound intensity, 121.64 $W/cm^2$ ; tarrageenan concentration, $2\%$; treatment time, 40 min. As the gel permeation chromatogram of dextran standards (M.W.= 500,000 ; 260,000 ; 167,000 ; 71,400 ; 42,000) and ultrsound treated carrageenan, the molecular weight of ultrasound treated carrageenan were approximately 200,000 (peak 1) and 60,000 (peak 2), respectively.

  • PDF

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.

Submucosal Tumor Analysis of Endoscopic Ultrasonography Images (내시경 초음파 영상의 점막하 종양 분석)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1044-1050
    • /
    • 2010
  • Endoscopic ultrasonography is a medical procedure in endoscopy combined with ultrasound to obtain images of the internal organs. It is useful to have a predictive pathological manifestation since a doctor can observe tumors under mucosa. However, it is often subjective to judge the degree of malignant degeneration of tumors. Thus, in this paper, we propose a feature analysis procedure to make the pathological manifestation more objective so as to improve the accuracy and recall of the diagnosis. In the process, we extract the ultrasound region from the image obtained by endoscopic ultrasonography. It is necessary to standardize the intensity of this region with the intensity of water region as a base since frequently found small intensity difference is only to be inefficient in the analysis. Then, we analyze the spot region with high echo and calcium deposited region by applying LVQ algorithm and bit plane partitioning procedure to tumor regions selected by medical expert. For detailed analysis, features such as intensity value, intensity information included within two random points chosen by medical expert in tumor region, and the slant of outline of tumor region in order to decide the degree of malignant degeneration. Such procedure is proven to be helpful for medical experts in tumor analysis.

Feature Analysis of Endoscopic Ultrasonography Images (내시경 초음파 영상의 특징 분석)

  • Kim, kwang-beak;Kang, hyo-joo;Kim, mi-jeong;Kim, gwang-ha
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.390-397
    • /
    • 2009
  • Endoscopic ultrasonography is a medical procedure in endoscopy combined with ultrasound to obtain images of the internal organs. It is useful to have a predictive pathological manifestation since a doctor can observe tumors under mucosa. However, it is often subjective to judge the degree of malignant degeneration of tumors. Thus, in this paper, we propose a feature analysis procedure to make the pathological manifestation more objective so as to improve the accuracy and recall of the diagnosis. In the process, we extract the ultrasound region from the image obtained by endoscopic ultrasonography. It is necessary to standardize the intensity of this region with the intensity of water region as a base since frequently found small intensity difference is only to be inefficient in the analysis. Then, we analyze the spot region with high echo and calcium deposited region by applying LVQ algorithm and bit plane partitioning procedure to tumor regions selected by medical expert. For detailed analysis, features such as intensity value, intensity information included within two random points chosen by medical expert in tumor region, and the slant of outline of tumor region in order to decide the degree of malignant degeneration. Such procedure is proven to be helpful for medical experts in tumor analysis.

  • PDF

A bond graph approach to energy efficiency analysis of a self-powered wireless pressure sensor

  • Cui, Yong;Gao, Robert X.;Yang, Dengfeng;Kazmer, David O.
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.1-22
    • /
    • 2007
  • The energy efficiency of a self-powered wireless sensing system for pressure monitoring in injection molding is analyzed using Bond graph models. The sensing system, located within the mold cavity, consists of an energy converter, an energy modulator, and a ultrasonic signal transmitter. Pressure variation in the mold cavity is extracted by the energy converter and transmitted through the mold steel to a signal receiver located outside of the mold, in the form of ultrasound pulse trains. Through Bond graph models, the energy efficiency of the sensing system is characterized as a function of the configuration of a piezoceramic stack within the energy converter, the pulsing cycle of the energy modulator, and the thicknesses of the various layers that make up the ultrasonic signal transmitter. The obtained energy models are subsequently utilized to identify the minimum level of signal intensity required to ensure successful detection of the ultrasound pulse trains by the signal receiver. The Bond graph models established have shown to be useful in optimizing the design of the various constituent components within the sensing system to achieve high energy conversion efficiency under a compact size, which are critical to successful embedment within the mold structure.

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.

Basic Study on the Design and Optimization of Sonoreactors for Sonochemical Water/Wastewater Treatment Processes (초음파 수처리 공정 개발을 위한 반응기 설계 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2014
  • Ultrasound technology can be applied in various fields including environmental, energy, and material engineering processes. In this study the effect of liquid height/volume on calorimetric energy and sonochemical oxidation was investigated as one of the basic steps for the design of water/wastereater treatment sonoreactors. The liquid height was increased from 0 to $4{\lambda}$ by $1/4{\lambda}$ and it was found that both calorimetric energy and sonochemical oxidation were significantly increased at relatively high liquid height/volume where the power density was relatively low. The sonochemiluminescence (SCL) images for the visualization of the activity of cavitation also showed that larger and more stable active zone was formed with high SCL intensity at high liquid height/volume. Therefore, it was revealed that sonoreactors for water/wasterwater treatment could be significantly effective in terms of removal efficiency and energy consumption.

Properties of Lower Molecular Weight of $\lambda$-Carrageenan Manufactured by Ultrasound (초음파에 의해 제조된 저분자 $\lambda$-carrageenan의 특성)

  • KIM Sang-Moo;PARK Seong-Min;CHOI Hyeon-Mee;LEE Keun-Tae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.607-611
    • /
    • 1999
  • Carrageenan are sulfated polymers containing galactose and anhydrogalctose units, and is used for its gelling, thickening, stabilizing, emulsifying, and suspending properties. However, carrageenan is limited to use beyond $0.03\%$ as food additives because of its high degree of gelling and viscosity with low solubility. The use of ultrasound significantly reduced the viscosity of $\lambda$-carrageenan solutions. The optimal parameters of ultrasound for reduction of carrageenan molecular weight were temperature, $10^{\circ}C$ ultrasound intensity, 114.7 $W/cm^2$ ; carrageenan concentration, $2\%$; treatment time, 10 min. The molecular weights of control, ultrasound peak 1, and peak 2 were approximately 250,000, 184,000, and 67,000 daltons, respectively. The lower molecular weight of $\lambda$-carrageenan showed the higher solubility, the lower alcohol precipitation ratio and the lower emulsifying capacity. Browning degree of both control and lower molecular $\lambda$-carrageenans was not significantly different.

  • PDF

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(I) : Analysis of Ultrasonic Parameters (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(I) : 초음파의 영향인자 평가)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on improving the flux and cleaning efficiency in membrane process which is widely applied for the treatment of landfill leachate. The experiments on improvement of membrane flux according to the types of membranes(hallowfiber microfiltration, MF and tubular ultrafiltration, UF) were performed with changing frequency($40{\sim}120$ kHz), intensity ($200{\sim}500$ W) and irradiation time of ultrasound as well us operation pressure($0.1{\sim}2.3kg/cm^2$). Membrane was fouled for the first 50 min with primary treated leachate and then the change in flux according to ultrasonic irradiation period was observed for 70 min. Parameters influenced to the recovery ratio corresponding the net flux on pure water and to the enhancement ratio applied after ultrasonic irradiation on the flux were analyzed. In same condition, the flux was improved in proportion to ultrasonic intensity while the improvement of flux was inversely proportional to ultrasonic frequency. The cleaning effect of membrane was delayed and reduced when operation pressure of membrane was high. The recovery ratio and enhancement ratio for $0.1{\mu}m$ MF membrane were 10% and 500%, respectively while those were maximized at $75{\sim}98%\;and\;40{\sim}50%$ for UF membrane for 10,000 and 100,000 MWCO, respectively. In conclusion, it was confirmed that ultrasonic cleaning using mechanical vibration is alternative to water or chemical cleaning for improving membrane flux.

Deep Burn Injuries on the Lower Abdomen after HIFU Treatment for Uterine Myoma (자궁 근종에 대한 HIFU 치료 후 발생한 하부 복부의 심부 화상)

  • Yu, Sung Hoon;Kim, Dong Chul
    • Journal of the Korean Burn Society
    • /
    • v.23 no.2
    • /
    • pp.64-67
    • /
    • 2020
  • High-intensity focused ultrasound (HIFU) has been regarded as a non-invasive uterine-preserving treatment for women with uterine myoma. Numerous studies have reported that it is a relatively safe and effective treatment for uterine myoma. However, severe complications, such as deep thermal burn injuries, bowel perforation, and bladder injury, were reported on rare occasions. We report a case of a 4th degree burn on the lower abdomen after HIFU treatment for uterine myoma. Physicians must consider the possibility of deep thermal burn injuries when managing uterine myoma with HIFU.