• Title/Summary/Keyword: high-damping rubber

Search Result 86, Processing Time 0.033 seconds

Comparative study of the seismic response of RC framed buildings retrofitted using modern techniques

  • Mazza, Fabio
    • Earthquakes and Structures
    • /
    • v.9 no.1
    • /
    • pp.29-48
    • /
    • 2015
  • The main purpose of this work is to compare different criteria for the seismic strengthening of RC framed buildings in order to find the optimal combinations of these retrofitting techniques. To this end, a numerical investigation is carried out with reference to the town hall of Spilinga (Italy), an RC framed structure with an L-shaped plan built at the beginning of the 1960s. Five structures are considered, derived from the first by incorporating: carbon fibre reinforced polymer (FRP)-wrapping of all columns; base-isolation, with high-damping-laminated-rubber bearings (HDLRBs); added damping, with hysteretic damped braces (HYDBs); FRP-wrapping of the first storey columns combined with base-isolation or added damping. A three-dimensional fibre model of the primary and retrofitted structures is considered; bilinear and trilinear laws idealize, respectively, the behaviour of the HYDB, providing that the buckling be prevented, and the FRP-wrapping, without resistance in compression, while the response of the HDLRB is simulated by using a viscoelastic linear model. The effectiveness of the retrofitting solutions is tested with nonlinear dynamic analyses based on biaxial accelerograms, whose response spectra match those in the Italian seismic code.

Seismic responses of base-isolated buildings: efficacy of equivalent linear modeling under near-fault earthquakes

  • Alhan, Cenk;Ozgur, Murat
    • Smart Structures and Systems
    • /
    • v.15 no.6
    • /
    • pp.1439-1461
    • /
    • 2015
  • Design criteria, modeling rules, and analysis principles of seismic isolation systems have already found place in important building codes and standards such as the Uniform Building Code and ASCE/SEI 7-05. Although real behaviors of isolation systems composed of high damping or lead rubber bearings are nonlinear, equivalent linear models can be obtained using effective stiffness and damping which makes use of linear seismic analysis methods for seismic-isolated buildings possible. However, equivalent linear modeling and analysis may lead to errors in seismic response terms of multi-story buildings and thus need to be assessed comprehensively. This study investigates the accuracy of equivalent linear modeling via numerical experiments conducted on generic five-story three dimensional seismic-isolated buildings. A wide range of nonlinear isolation systems with different characteristics and their equivalent linear counterparts are subjected to historical earthquakes and isolation system displacements, top floor accelerations, story drifts, base shears, and torsional base moments are compared. Relations between the accuracy of the estimates of peak structural responses from equivalent linear models and typical characteristics of nonlinear isolation systems including effective period, rigid-body mode period, effective viscous damping ratio, and post-yield to pre-yield stiffness ratio are established. Influence of biaxial interaction and plan eccentricity are also examined.

Cable vibration control with internal and external dampers: Theoretical analysis and field test validation

  • Di, Fangdian;Sun, Limin;Chen, Lin
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.575-589
    • /
    • 2020
  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.

Effects of Thermal Aging of Natural Rubber Bearing on Seismic Performance of Bridges (천연고무받침의 열 노화가 교량 내진성능에 미치는 영향)

  • Oh, Ju;Jung, Hie-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.855-864
    • /
    • 2013
  • The dynamic characteristics of natural rubber bearings, which are used as isolator, are dependent on the main rubber's dynamic behaviors and nonlinear properties. Rubber materials tend to undergo an aging process under the influence of mechanical or environmental factors, so they inevitably end up facing damage. A main cause of aging like this is known to be oxidization, which occurs through the heat of reaction at high temperatures. Accordingly, in this study an accelerated thermal aging test was carried out in order to compare the characteristic values of the bearings before and after thermal aging occurs. As a result of this experiment, it was found that a thermal aging phenomenon could have some effects on shear stiffness, energy absorption, and equivalent damping coefficients of the bearings. Furthermore, a deterioration in the dynamic properties of the natural rubber bearings caused by the thermal aging was applied to an actual bridge and then the effects of such thermal aging on the seismic performance of the bridge were also compared and analyzed based on numerical analysis. As a result of this analysis, it was found that the changes in the basic properties of the natural rubber bearings caused by the thermal aging bring only a minor effect on the seismic performance of bridges.

Influence of Aging of Lead Rubber Bearing on Seismic Performance of Bridges (납고무받침의 노화가 교량의 내진성능에 미치는 영향)

  • Park, Seong-Kyu;Oh, Ju
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.109-116
    • /
    • 2012
  • The dynamic properties of lead rubber bearings, which are used as isolator, are dependent on the main rubber's dynamic behaviors and nonlinear qualities. Rubber materials tend to undergo an aging process under the influence of mechanical or environmental factors, so they can end up inevitably facing damage. A main cause of such aging is known to be oxidization, which occurs through the heat of reaction at high temperatures. Accordingly, in this study an accelerated thermal aging test was carried out in order to compare the characteristic values of the bearings with each other before and after thermal aging occurs. As a result of this experiment, it was found that a thermal aging phenomenon could have an effect on shear stiffness, energy absorption, and equivalent damping coefficients. Furthermore, a decline in the dynamic properties of the lead rubber bearings by means of the thermal aging process was applied to an actual bridge and the effects of such thermal aging on the seismic performance of the bridge were also compared and analyzed based on numerical analysis. As a result of this analysis, it was found that the changes in the basic properties of the lead rubber bearings have a minor effect on the seismic performance of bridges.

An Experimental Study on Dynamic Properties of Concrete with Vibration-Mitigation Materials (제진재 혼입 콘크리트의 동적물성에 관한 실험적 연구)

  • Chung, Young-Soo;Park, Yong-Goo
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.261-270
    • /
    • 1999
  • In these days, construction activities have caused civil petitions associated with vibration-induced damages or nuisances. Therefore, it is strongly needed to develop a remedial technique to mitigate unfavorable effects. The objective of this experimental research is to investigate material and structural dynamic characteristics of vibration-controlled concretes which have been proportionally mixed with various vibration reducing material, such as latex, rubber powder, plastic resin, polystyrofoams and etc. Normal and high strength concrete specimens are also prepared for corresponding comparison. As part of the recycling research for obsolete rubber and plastic materials, 32 concrete cylinders and 10 concrete flexural beams have been made for material and structural dynamic properties, respectively. In accordance with the resonance test on concrete cylinders, it can be concluded that concrete with vibration-reducing material have relatively larger material damping ration than normal or high strength concrete. Styrofoam is determined to be very effective vibration-reducing mixtures. From the vibration test on 10 concrete flexural beams, meamwhile, of importance observations was that material damping ratio is very smaller than structural damping ratio of corresponding specimen. But further vibration test on more flexural beams should be strongly needed by varying support conditions.

Shaking Table Test of Rectangular Liquid Container with Base-Isolation System (사각형 면진유체저장조의 진동대실험)

  • 전영선;최인길
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.122-129
    • /
    • 1995
  • The seismic behavior of a rectangular liquid container with high damping laminated rubber bearing is investigated through the scaled model tests. The results are compared with those for non-isolated model, and those by analytical methods. It is shown that the optimum dynamic properties of isolation system can reduce the acceleration response in the superstructure significantly and prevent the amplification of sloshing height.

  • PDF

Development of Guidelines for seismic isolation Design of LMR (액체금속로 면진설계를 위한 지침서 개발)

  • Yoo, Bong;Koo, Gyeong-Hoi;Lee, Jae-Han
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.147-154
    • /
    • 1998
  • The purpose of this paper is to propose the draft guidelines of seismic isolation design of Liquid Metal Reactor (LMR) using high damping laminated rubber bearings. The scopes of guidelines include design requirements of a seismically isolated system and components, seismic isolator, isolation system, interface system between seismic isolation and non-seismic isolation part, qualification and acceptance tests of seismic isolator, seismic isolation reliability, and seismic safety and monitoring system. Proposed guidelines shall be revised to extend to general design guideline for nuclear facilities by further research and discussions.

  • PDF

Optimum Design of Viscous Torsional Vibration Damper Using Random Tabu Search Method (Random Tabu 탐색법을 이용한 점성 비틀림 진동감쇠기의 최적설계)

  • 김유신;양보석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.301-306
    • /
    • 1996
  • A torsional damper is generally used to reduce the torsional vibration which occurs at a crankshaft of a multi-cylinder high speed diesel engine. Vibration amplitude should be estimate by the appropriate simulation model to determine the optimum specifications of damper. In this paper a new method which was based on the random tabu search method(RTSM) would be introduced for the viscous damper design to optimize the damping performance. The result was ascertained by comparing with conventional rubber damper.

  • PDF

A study to determine the Design parameters of high speed freight wagon (고속화차용 현가장치 적정 설계변수 선정에 관한 연구)

  • 김남포;김종호
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.484-490
    • /
    • 2000
  • The freight wagon with weld fabricated 1-piece bogies, which was developed to increase operating speed, reveals its difficulties in maintenance. The weld-fabricated bogies were composed of two-stage coil spring and dry friction damping mechanism. The inborn wear parts and rather complicated structure mattes bogie maintenance difficult. In order to relieve this difficulties, the application of maintenance free rubber suspension is proposed by bogie maunfacturer, Taeyang Precision Limited. This study was conducted to determine design parameters of proposed rubber suspension by means of vehicle dynamic simulation and parametric study. The target critical speed of bogie was set over 150km/h for the preparation of further speed-up of freight wagon.

  • PDF