• Title/Summary/Keyword: high-Tc

Search Result 1,528, Processing Time 0.032 seconds

Oxidative Degradation of PCE/TCE Using $KMnO_4$ in Aqueous Solutions under Steady Flow Conditions (유동조건에서 $KMnO_4$도입에 따른 수용액중 PCE/TCE의 산화분해)

  • Kim, Heon-Ki;Kim, Tae-Yun
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.685-693
    • /
    • 2008
  • The rates of oxidative degradation of perchloroethene (PCE) and trichloroethene (TCE) using $KMnO_4$ solution were evaluated under the flow condition using a bench-scale transport experimental setup. Parameters which are considered to affect the reaction rates tested in this study were the contact time (or retention time), and the concentration of oxidizing agent. A glass column packed with coarse sand was used for simulating the aquifer condition. Contact time between reactants was controlled by changing the flow rate of the solution through the column. The inflow concentrations of PCE and TCE were controlled constant within the range of $0.11{\sim}0.21\;mM$ and $1.3{\sim}1.5\;mM$, respectively. And the contact time was $14{\sim}125$ min for PCE and $15{\sim}36$ min for TCE. The $KMnO_4$ concentration was controlled constant during experiment in the range of $0.6{\sim}2.5\;mM$. It was found that the reduction of PCE and TCE concentrations were inversely proportional to the contact time. The exact reaction order for the PCE and TCE degradation reaction could not be determined under the experimental condition used in this study. However, the estimated reaction rate constants assuming pseudo-1st order reaction agree with those reported based on batch studies. TCE degradation rate was proportional to $KMnO_4$ concentration. This was considered to be the result of using high inflow concentrations of reactant, which might be the case at the vicinity of the source zones in aquifer. The results of this study, performed using a dynamic flow system, are expected to provide useful information for designing and implementing a field scale oxidative removal process for PCE/TCE-contaminated sites.

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

Effects of Exercise Training and Selenium on MCT1 and MCT4 Protein Levels in Skeletal Muscles of Diabetic Goto-Kakizaki Rats (지구성 운동과 셀레니움 투여가 당뇨 Goto-kakizaki 쥐의 골격근의 MCT1과 MCT4단백질 발현수준에 미치는 효과)

  • Kim, Seung-Seok;Kang, Eun-Bum;Eum, Hyun-Sub;Kim, Bum-Su;Lim, Yea-Hyun;Park, Joon-Young;Cho, In-Ho;Oh, Yoo-Sung;Kwak, Yi-Sub;Cho, Joon-Yong
    • Journal of Life Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to determine the possible additive effects of endurance exercise training (EXER) and selenium (SELE) on the improvements of glucose and lactate transport capacities in diabetic Goto-kakizaki rats. Animals either remained sedentary control (SED) or performed EXER or received SELE [$5{\mu}mol$ kg body wt (-1) day (-1)], or underwent both EXER and SELE (COMBI), which lasted for 6 wk. Compared with sedentary control, EXER alone or the SELE alone group, or the combined treatment group had significant reduction in glucose response measured at 90 min and 120 min during an intraperitoneal glucose tolerance test (IPGTT) and body weight after 6week treatment. EXER alone, or combined group individually had significantly higher glycogen contents in liver compared with SED or SELE groups. EXER alone increased glycogen content in soleus and plantaris compared with SED, and this parameter was increased to greatest extent in the combined treatment groups compared with SED or SELE groups. EXER alone, SELE alone or COMBI, caused significant decreases in the plasma lactates, serum glucose, insulin, total cholesterol and HOMA-IR along with a significant increase in high-density lipoprotein cholesterol compared with SED. In addition, EXER or COMBI individually had significantly lower serum triacylglycerol compared with SED or SELE. With respect to protein expression related to glucose and lactate transport capacities, EXER alone, SELE alone, or COMBI increased in MCT1 and MCT4 protein level in soleus and plantaris. Furthermore, EXER alone, SELE alone or COMBI caused significant increases in mt MCT1 protein level in soleus and plantaris. The findings of the current study suggest that endurance exercise training and selenium treatment may provide therapeutic values to type II diabetic patients with peripheral insulin resistance and hyperlactatecemia by improving glucose and lactate transport capacities, leading to improvements in plasma lactate, serum glucose, insulin and lipid profiles (TC, TG, HDL).

Occurrence and Distribution of Selected Veterinary Antibiotics in Soils, Sediments and Water Adjacent to a Cattle Manure Composting Facility in Korea (국내 우분 퇴비화 시설 인근 농경지 및 수계 중 Tetracycline 및 Sulfonamide 계열 항생물질의 분포특성)

  • Lim, Jung-Eun;Kim, Sung-Chul;Lee, Hyeon-Yong;Kwon, Oh-Kyung;Yang, Jae-E.;Ok, Yong-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.845-854
    • /
    • 2009
  • There has been increased concern regarding the release of antibiotics to different environmental compartments due to the possibility of the development of antibiotic resistant bacteria. However, limited information is available regarding the occurrence, fate, and transport of antibiotics in Korea in both the aqueous phase and in solid phases such as sediment and soil. Therefore, this study was conducted to monitor the concentration of released antibiotics in surface water, sediment, and soil adjacent to a cattle manure composting facility in Korea. Specifically, the following six antibiotics were monitored: tetracycline (TC), chlortetracycline (CTC), oxytetracycline (OTC), sulfamethazine (SMT), sulfamethoxazole (SMX), and sulfathiazole (STZ). To extract and quantify the antibiotics from different environmental compartments, solid phase extraction (SPE) and high performance liquid chromatography mass spectrometry (HPLC/MS) techniques were adopted. The concentration of the six antibiotics ranged from below the detection limit (BDL) to 0.71 ${\mu}g$/L in surface water, from BDL to 27.61 ${\mu}g$/L in sediment, and from 0.12 to 157.33 ${\mu}g$/L in soil. In addition, higher concentrations of antibiotics were observed in surface water and sediment at locations closer to the composting facility indicating that composting is the source of the antibiotics found in the environment. Furthermore, higher concentrations of antibiotics were observed in the solid phase (sediment and soil) than the aqueous phase. These findings indicate that the possibility of antibiotic resistant bacteria is increased because such bacteria are more stable in the solid phase. Overall, longterm monitoring of the aqueous phase and solid phase is necessary to gain a better understanding of the impact of antibiotics from source on the environment in Korea.

Application of a New Conjugation Method to Fish Pathogenic Bacteria Containing R Plasmid for the Analysis of Drug-Resistant Status in Aquaculture (새로운 conjugation 방법을 응용한 R plasmid 함유 어병세균의 분리와 양식장 내성균의 현황 분석)

  • Yoo Min Ho;Jeong Joon Beom;Kim Eun Heui;Lee Hyoung Ho;Jeong Hun Do
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • To develop a new method of conjugation and to determine the distribution of R plasimds, we isolated multi-drug resistant strains from fish pathogenic bacteria in the farms of south and east seacoasts of Korea. Out of the 134 isolates examined, 10 showed resistance to chloramphenicol, tetracycline, streptomycin, ampicillin, colistin, nalidixic acid, oxolinic acid and kanamycin. One out of 10 multi-drug resistance bacteria, Vibfio damsela JE1 (V. damsela JE1), contained transferable R plasmid of chlorarnphenicol- tetracycline resistance genes and other nucleic acids encoding ampicillin and kanamycin resistance. The presence of the R plasmid was confirmed by conjugation using the chromocult medium (CC) as a selective and differential medium for transconiugants with identification based on the growth or colors of the colonies. The frequency of R plasmid transfer with filter mating method was come out much higher than that of broth mating method and appeared to be dependent upon the mating time and temperature. The optimum conditions for filter mating method were found to be 30$^{\circ}C$ and 24hrs as mating temperature and period, respectively, Moreover, donor cells with R plasmid, both isolate and standard bacteria, were shown to have an ability to transfer the plasmid against Escherichia coli K-12 HB101 (E. coli HB101) and Edwardsiella tarda (E. tarda) RE14 at fairly high frequencies, finally, we isolated 3 isolates of Sphingomonas sp., carrying R plasmid from 12 multi-drug resistant bacteria in normal microflora of the flounder (Paralichthys olivaceus) group used for the isolation of V emsela JE1 four months before. The same size and gene transfer chayateristics of R plasimds with those of V damsela JE1 confirmed that normal microflora have the reservoir activity for R plasmid in natural aquatic environment.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.