• Title/Summary/Keyword: high voltage corona discharge

Search Result 92, Processing Time 0.029 seconds

Dismantled PD diagnosis on 6.6kV Stator Winding by Using Spiral Patch Antenna Sensor (분리된 6.6kV급 고정자 권선의 부분방전 측정을 위한 Spiral 패치 안테나 센서 적용 연구)

  • Lwin, Kyaw Soe;Shin, Dong-Hoon;Lim, Kwang-Jin;Yang, Hoon;Kong, Tae-Sik;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.211-212
    • /
    • 2007
  • There have three kinds of partial discharge diagnosis testing: online, offline and dismantled testing on high voltage rotating machine. Our lab testing is dismantled testing, taking off pieces into individual parts of stator coil of high voltage rotating machine in laboratory. We investigate internal discharge, slot discharge, corona discharge and normal state on pre-made stator winding by using spiral patch antenna sensor. In this lab test we compare the experimental results of our spiral patch antenna sensor and reference commercial HFCT sensor.

  • PDF

High Voltage Nano-Pulse Generator for Industrial Waste Water Treatment (폐수 처리용 고전압 나노 펄스 발생기)

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Kwon, O-Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.311-318
    • /
    • 2001
  • The application of a pulsed power system is being extended to a environmental and industrial fields. The non-dissolution waste water pollutants from industrial plants can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The nano-pulse generator with a magnetic switch has been developed. Its corona current in load can be adjusted by pulse width and repetition rate. we investigated the performance of the nano-pulse generator using the dummy load which is composed of resistor and capacitor equivalent to the actual reactor. This paper descibes the electrical characteristics of the nano-pulse generator that produces a 300 ns pulse at maximum repetition rate of 400 pps with a voltage of 40 kV across a $640{\Omega}$ load. In this paper we briefly discuss a configuration of system and test results.

  • PDF

Discharge Characteristics and UV Images at Air on Bushing Model with Contaminations (기중 부싱모델의 오염물질에 따른 방전 특성과 자외선 이미지)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.12
    • /
    • pp.996-1001
    • /
    • 2011
  • A bushing is very important because it must supply the high voltage to the power equipment. Generally, the surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations at air are serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics on bushing model with contaminations. Also, UV images of discharge in air are analyzed using prototype UV camera of Korea. These results are studied at both AC and DC voltage under a non-uniform field.

Experimental Studies on the Motion and Discharge Behavior of Free Conducting Wire Particle in DC GIL

  • Wang, Jian;Wang, Zhiyuan;Ni, Xiaoru;Liu, Sihua
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2017
  • This study aims to restrain free conducting wire-type particles which are commonly and dangerously existing within DC gas-insulated transmission lines. A realistic platform of a coaxial cylindrical electrode was established by using a high-speed camera and a partial discharge (PD) monitor to observe the motion, PD, and breakdown of these particles. The probabilities of standing or bouncing, which can be affected by the length of the particles, were also quantitatively examined. The corona images of the particles were recorded, and particle-triggered PD signals were monitored and extracted. Breakdown images were also obtained. The air-gap breakdown with the particles was subjected to mechanism analysis on the basis of stream theory. Results reveal that the lifting voltage of the wire particles is almost irrelevant to their length but is proportional to the square root of their radius. Short particles correspond to high bouncing probability. The intensity and frequency of PD and the micro-discharge gap increase as the length of the particles increases. The breakdown voltage decreases as the length of the particles decreases.

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

A Study on ther Water Plasma Chemical Process Discharge by Pulse Power Supply (펄스전원을 이용한 수중플라즈마 방전에 관한 연구)

  • Shin, Wan-Ho;Hong, Won-Seok;Yoo, Hyo-Yol;Park, Sun-Soon;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2179-2181
    • /
    • 2005
  • An experimental study on the water plasma characteristics of removal efficiency for organic contaminants in dye waste water has been investigated. In this study, dielectric barrier discharging electrodes with round shape have disposed cross each other in reactor, and pulse power was supplied to between each electrodes. Its output pulse voltage range is from 0[V] to 30[kV] and output frequency range is from 100[Hz] to 2[kHz]. Using proposed system, High frequency discharge is tested in the mixed Tone(air and water) and the space distribution of streamer corona plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric (SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해)

  • Eo, Joon;Kim, Il Won;Park, Jin Do;Lee, Joo Young;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.249-254
    • /
    • 2011
  • A nonthermal plasma reactor in conjunction with a tubular type with a ferroelectric (high-dielectric ceramic) pellet layer was designed and constructed. $SrBiTaO_9$ (SBT) pellets with 2.0 mm in diameter were held within the tube arrangement by two metal mesh electrodes (20 mm separation) connected to a high-voltage AC power supply. The dielectric constant of SBT pellets was 150 at room temperature and 500 at curie temperature ($335^{\circ}C$). The generation rate of ozone in the plasma reactor almost linearly increased with increasing applied voltage. In the case of the plasma reactor packed with SBT pellets the generation rate of ozone sharply increased at the applied voltage more than 20 kV. The ozone generation rate at the negative corona discharge was higher than that of the positive corona discharge. However, the destruction efficiency of toluene and methylene chloride was not increased in proportion to ozone concentration.

Analysis of efficient ozonizer character using high-frequency Inverter (고주파 인버터를 이용한 고농도 오존발생기 특성 해석)

  • Kim, Y.H.;Hwang, Y.M.;Noh, I.B.;Kim, Y.B.;Woo, S.H.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1006-1008
    • /
    • 2002
  • Recently deep interests and attractions have been paid on the generation of ozone with environment polisy. Especially, which is widely used to remove bad smell and to clear water. This paper presents control and performance of a voltage source IGBT inverter developed for silent corona discharge type ozonizer. And proposed addition circuit for maintain discharge the center of in the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of ozonizer is investigated in the simulation and experimental results.

  • PDF

Al-foil Electrode for Detecting Partial Discharge in Middle Joint Box (초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극)

  • Shin, Hyun-Mahn;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.211-213
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analysed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용)

  • Lee, Jung-Soo;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.214-217
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding Power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF