• Title/Summary/Keyword: high voltage corona discharge

Search Result 92, Processing Time 0.02 seconds

Experimental Study on the Effect of Plasma Reactor Type on Corona Discharge and NO-NO2 Conversion Characteristics (플라즈마 반응기구조에 따른 코로나방전 및 NO-NO$_2$ 전환특성에 관한 실험적 연구)

  • 박용성;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.65-71
    • /
    • 2002
  • Characteristics of corona discharge of the different types of the plasma reactors which are cone-hole and cone-plate is investigated experimentally. The discharge starts at lower voltage for the cathode corona than the anode corona and spark occurs at higher voltage for the cathode corona. And the cathode corona makes more stable discharge than the anode corona. The effect of the base gas in corona discharge for different O$_2$/N$_2$ concentrations is related with the gas molecular weight. The discharge for the smaller molecular weight gas occurs easier than for the high molecular weight gas. The discharge current decreases with the increase of oxygen concentration and it increases more sharply for anode corona than for cathode corona as discharge voltage increases after corona onset voltage. NO-NO$_2$ conversion increases with the energy density of corona discharge and the addition of O$_2$ in a base N$_2$ gas.

Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries (핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구)

  • Cheong Seongir;Lee Jaekeun;Chung Dongkyu;Ahn Youngchull
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

ORGANIC POLLUTANTS DEGRADATION USING PULSELESS CORONA DISCHARGE: APPLICATION IN ULTRAPURE WATER PRODUCTION

  • Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.144-154
    • /
    • 2005
  • The use of ozone gained acceptance in the production of ultrapure water because of its powerful oxidizing ability. Ozone is currently used to deactivate microorganisms and remove organic contaminants. However, interest also exists in using radical species, which arc stronger oxidants than ozone, in such processes. One means of producing radical species is by corona discharge. This work investigates the use of a novel pulseless corona-discharge system for the removal of organic substances in ultrapure water production. The method combines corona discharge with electrohydrodynamic spraying of oxygen, forming microbubbles. Experimental results show that pulseless corona discharge effectively removes organics, such as phenol and methylene blue, in deionized water. The corona-discharge method is demonstrated to be comparable to the direct use of ozone at a high-applied voltage. The results also show that a minimum applied voltage exists for operation of the corona-discharge method. In this work, the minimum applied voltage is approximately 4.5 kV. The kinetic rate or phenol degradation in the reactor is modeled. Modeling results show that the dominant species of the pulseless corona-discharge reactor are hydroxyl radical and aqueous electron. Several radical species produced in the pulseless corona-discharge process are identified experimentally. The. major species are hydroxyl radical, atomic hydrogen species, and ozone.

Electrohydrodynamic Characteristics of AC Corona Discharge for the Frequency (교류 코로나 방전시 주파수 변화에 따른 전기유체역학적 특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.87-92
    • /
    • 2012
  • In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

Corona Discharge Phenomena on the Dielectric Electrodes in High Field (고전계하에서 유전체 전극에 나타나는 코로나 현상)

  • Kim, Jung-Dal;Lee, Duck-Jin;Joo, Sung-Cheol;Jung, Jang-Gun;Chang, Gi-Hyuk;Lee, Sae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF

A STOCHASTIC MODEL TO PREDICT RADIO INTERFERENCE CAUSED BY CORONA ON HIGH VOLTAGE TRANSMISSION SYSTEMS

  • Jo, Yeon-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1985.07a
    • /
    • pp.127-130
    • /
    • 1985
  • A stochastic model to predict radio interference field as caused by corona discharges on high voltage transmission lines has been developed. This model is based on corona discharge distributed randomly in time and space. A stochastic model for the corona current induced by corona discharges on power lines is proposed. On the basis of the proposed corona current model, a rigorous analysis is presented to evaluate the radio interference (RI) field caused by corona discharges on a single conductor using the stochastic method.

  • PDF

Analysis of high-frequency resonant Inverter character using efficient ozonizer (고효율 오존생기용 고주파 공진형 인버터의 특성 해석)

  • Kim, Young-Hoon;Hwang, Young-Min;Noh, In-Bae;Kim, Young-Bin;Heo, Tae-Won;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

A Study on Conductivity Characteristics of Insulating Oil by Corona Discharge in Oil (유중(油中)코로나 방전(放電)으로 인(因)한 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究))

  • Kim, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.71-83
    • /
    • 1979
  • Not only the insulating oil used for extra high voltage and high capacity transformer has a lot of possibilites of a corona discharge in oil, but the oil is easily degraded by a response of light oxidization. This study is either to classfy, with priority given to a transformer oil produced in Korea belonging to, the insulating oil No. 2, the sample irradiated the ultraviolet rays, treated a corona discharge in oil by a high voltage DC source and done nothing, or to measure the characteristics of breakdown, V-i, I-t and electrode material. The obtained results can be summarized as followings: (1) Unless the sample is contacted with the air, on the process to irradiate the ultraviolet rays, the sample less influence on the changes of the electric characteristics. At the same time, if the sample is contacted with the air and irradiated the ultraviolet rays, the sample shows a remarkable changes of the electric characteristics, and a declined breakdown strength. This tells us that the influence of the light irradiation must be considered as a primary factor of degrading the insulating oil. (2) In the oil treated by a corona discharge, breakdown voltage is declined more than in the oil not to be treated with it. This means that the degradation of the insulating oil is getting increased by a corona discharge in oil. (3) It shows that the increase of conducting current has little to do with breakdown voltage. (4) The conducting current depending on the electrode materials can be put in order by value as Al>Cu>Fe. This is due to the differences of the work function of each metals, and an chemical reaction with the insulating oil. These result can be a great help in verifying the degradation progress of the insulating oil and furnish a new technical information to the manufacturers of the insulating oil and electrical equipment designers and operators. Besides, this study would be helpful to improve the electrical characteristics of the insulating oil produced in Korea.

  • PDF

Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor (AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF