• Title/Summary/Keyword: high turbidity

Search Result 495, Processing Time 0.02 seconds

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

Quality Characteristics of Dried Noodles Added with Ligularia fischeri Powder (곰취 분말을 첨가한 국수의 품질특성)

  • Park, Bock Hee;Joo, Ha Mi;Cho, Hee Sook
    • Journal of the Korean Society of Food Culture
    • /
    • v.29 no.2
    • /
    • pp.205-211
    • /
    • 2014
  • This study investigated the quality of noodles containing different amounts of Ligularia fischeri powder (LFP). Noodles were prepared at ratios of 0, 1, 3, 5, and 7% LFP based on flour weight. Cooking quality, mechanical texture properties, and viscosity were measured, and a sensory evaluation was performed with the prepared noodles. Gelatinization points of the composite LFP-wheat flours increased. As measured via amylography, viscosity at $95^{\circ}C$, viscosity at $95^{\circ}C$ after 15 minutes, and maximum viscosity values of samples decreased, as the LFP content increased. As increasing amounts of LFP were added, the L, a, and b values decreased while color values, weight, and volume of cooked noodles increased, as did the turbidity of the soup. With regard to textural characteristics, LFP additive increased hardness, cohesiveness, and springiness, while decreasing adhesiveness. Sensory evaluation showed that high quality cooked noodles could be produced by inclusion of 3% LFP.

Removal of Natural Organic Matter by Mixing Coagulants in Coagulation Process (응집공정에서 혼합응집제 주입에 의한 자연유기물질의 제거)

  • 명복태;우달식;최종현;이윤진;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.60-66
    • /
    • 2001
  • Natural organic matters(NOMs) are found everywhere such as soil, surface and ground waters and consist of both humic and nonhumic components, and their heterogeneith makes each source unique. This study was carried to evaluate the removal characteristics of NOMs by mixing coagulants and the variation of apparent molecular weight distribution(AMWD) in coagulation process. Ratio of optimum coagulants dosage for removal of DOC and turbidity by mixing coagulants was 1.83 mM F $e^{3+}$/mM $Al^{3+}$. DOC removal increased at lower pH. The pH6 control focused on the removal of organic matters could reduce the amount of coagulant consumption by 2 to 3 times based on the pH8.5 of natural water. The dissolved organic matters in the natural water from the mid-stream of Han River were composed of the low molecular weight(LMW,<1 K) of 59.7%, and the medium and high molecular weight(M.HMW, 1~30 K) of 40.3%, respectively. At pH6, the DOC removal efficiencies of LMW(<1 K) and M.HMW(1~30 K) in coagulation process were 27~35%, 62~72%, respectively. The fraction smaller than 1 K was not eliminated to a noticeable degree, while the fraction of 1~30 K was relatively well removed. In conclustion, mixing coagulants were fairly effective in the removal of natural organic matter.r.

  • PDF

Studies on the Water Quality of Ground Water in Seoul Area and Correlation Analysis Among their Contaminants (서울지역 지하수의 오염도와 성분별 相關性 檢討)

  • Ahn, Soo-Mi;Oh, Soo-Kyoung;Park, Sung-Bae
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.1
    • /
    • pp.51-62
    • /
    • 1989
  • This survey was performed to investigate contamination degree and significance in each item of 406 samples of ground water, which was collected in Seoul area from Jan. to Dec. 1988. The results of this study were as follows 1. The unsuitable rate of ground water investigated was 69.7%(32.4% in only bacteria, 23.6% in both bacteria and physico-chemistry and 13.6% in only physico-chemical contamination). 2. The unsuitable rate in each item was the highest(54.2%) in standard plate countland 29.8% in coliform, 12.8% in turbidity, 11.3% in Zn, and 10.8% in Mn. 3. The total mean concentrations in each item were lower than standard except standard plate count, coliform, and Fe. 4. In the analysis of corelation, among items, both total hardness and residual solids were showed very high correlationship (P < 0.01) with other items, and both S.P.C. and coliform showed very highly significant (P < 0.01) with NH$_3$-N.

  • PDF

Influence of Different Mixing Types on the Removal of Natural Organic Matter in Water Treatment (정수처리시 천연유기물질의 제거에 대한 급속혼화유형의 영향)

  • Kim, Hyun-Chul;Yu, Myong-Jin;Lee, Seock-Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.370-377
    • /
    • 2005
  • Dispersion of coagulant should be completed in a fraction of a second before the metal hydroxide precipitate has form. For the reason so-called pump diffusion flash mixing (PDFM) have been proposed, and PDFM is one of reasonable methods to quickly disperse the hydrolyzing metal salts. In this study, therefore, we attempt to understand the difference of removal characteristics of natural organic matter (NOM) between pump diffusion flash mixing (PDFM) and conventional rapid mixing (CRM) for coagulation in a water treatment system, and to enhance the removal of NOM through the improved mixing process. DOC and turbidity removal by PDFM higher than those by CRM, while SUVA value of water treated by PDFM was high as compared with that by CRM. Hydrophilic NOM was more effectively removed by PDFM than CRM, since charge neutralization effect increased by quick dispersion of coagulant. The DBP formation potentials due to NOM was effectively reduced by the improved mixing (i.e., PDFM) for coagulation and could be controlled through decrease in concentration of precursor rather than reduction of activity with disinfectant.

From Deep Bed Filter to Membrane Filtration: Process Intensification, Cost and Energy Considerations (입자분리를 위한 여과방식에 따른 비용-효율 분석)

  • BEN AIM, Roger;Kwon, Dae-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.144-148
    • /
    • 2005
  • The industrial development of large scale deep bed filters has been a very important step in the process of drinking water production and more recently in the tertiary treatment of wastewater. The target of deep bed filtration is the retention is the retention of small particles generally smaller than 30 microns at relatively small concentration, generally less than 30 mg/l from natural water (surface water or aquifers) or secondary treated wastewater. The relation between the retention efficiency and the characteristics of the particles has been extensively studied experimentally and through different models of retention. During the last years the development of new technologies (fiber filter, membrane modules) lead to more intensive processes compared to conventional sand filtration. Fiber filters can combine intensification with a decrease in specific energy needed however they cannot be operated under gravity like sand filters. Membrane filters (UF or MF) are much more intensive and efficient than sand filters. The specific energy needed is not so high (about $0.1Kwh/M^3$) but is higher than sand or fiber filter. A Life Cycle Analysis (LCA) has to be made for a complete comparison between these technologies taking in account that the efficiency of particle retention obtained by membrane filters is unique.

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Study on the Korean Waters using the CAL/VAL of the OSMI Level 2 Data

  • Suh, Young-Sang;Jang, Lee-Hyun;Mitchell, B.G.;Kahru, M.;Prasad, Kota;Shin, H.Y.
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.3
    • /
    • pp.127-139
    • /
    • 2002
  • A comparison was made between the chlorophyll $\alpha$ and suspended solid (SS) retrievals from OSMI and SeaWiFS sensor to chlorophyll $\alpha$ and SS values determined with the standard method during the NFRDI's research cruises. The percentage of organic and inorganic materials from the SS was calculated to study the contribution of turbid water in the northern part of the East China Sea. The open sea waters in the Kuroshio regions of the East China Sea showed relatively higher concentration of volatile SS. However, towards the northwestern part of the East China Sea, the situation became much more optically different with the non-volatile SS from the Yangtze river and the sea bottom sources in the sea in winter and spring seasons. Furthermore, in order to indirectly detect low salinity water with high turbidity, which related to the Yangtze river using remote sensed data from the satellites, a comparison between the results of the band ratio(nLw 490nm/nLw 555nm) of SeaWiFS(OSMI) and the distribution of low salinity around the Jeju Island was presented.

Fluoride removal using Alum & PACl in batch & continuous mode with subsequent microfiltration

  • Dubey, Swati;Agarwal, Madhu;Gupta, A.B.
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.83-93
    • /
    • 2021
  • In this study, defluoridation efficiency by aluminium sulphate (alum) and polyaluminium chloride (PACl) were compared for recommended Nalgonda dose (100%) and 80% of this dose in both batch and continuous modes. The residual turbidity was found to be higher in case of alum as compared to PACl with 80% dose representing lesser efficient settling of suspensions, which primarily comprise alumino-fluoro complexes that result in high residual aluminium in the treated water and this was confirmed by TEM and Zeta analysis. Moreover, the application of PACl also resulted in much lesser addition to the TDS and also required lesser lime for pH compensation due to its lower acidity. Hence this reduced dose was recommended for defluoridation. It was also observed that in case of alum, residual aluminium in treated water was 0.88 mg/L (100% dose) & 0.72 mg/L (80% dose) and in case of PACl, it was 0.52 mg/L(100% dose) & 0.41 mg/L(80% dose). After subsequent microfiltration, residual aluminium was 0.28 & 0.21 mg/L for 100% & 80% dose respectively and in case of alum and in case of PACl, it was 0.16 & 0.11 for 100% & 80% dose respectively, which conform to the Al standards(<0.2 mg/L).

Research Trend of OCA (Optically Clear additive) for Display Panel by Analysis of Patent and Papers Publication (특허 및 논문 분석을 통한 디스플레이용 접착제의 기술경쟁력 분석)

  • Woo, Chang Hwa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.75-84
    • /
    • 2018
  • According to IHS, the overall display market is expected to grow at an average annual rate of 6% from $ 104 billion in 2016, to $ 138 billion in 2021. Among them, the OLED display panel will grow from $ 15 billion to $ 41 billion over the same period, forecasting a high annual growth rate of 22%. However, the refraction index, light leakage, bubble generation, adhesion deterioration, peeling phenomenon, moisture resistance, light transmittance, low turbidity. OCA (optically clear adhesive), which solves problems such as improving the resistance of the conductive film, is largely dependent on imported products. In addition, in 2016, the world market is worth KRW4.3 trillion, and the adhesive market has a large market effect. In this study, we tried to analyze the technical competitiveness of patent and thesis by classifying OCA (optically clear adhesive, optical adhesive) for display panel by curing method. As a result of the study, the amount of patents and papers in Korea was found to be superior to other competitors, but the quality level was low. In particular, it was found that the achievements of the papers in the hot melt field are lacking and the government should expand its support.