• Title/Summary/Keyword: high tower

Search Result 551, Processing Time 0.023 seconds

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

Genetic Studies in Some Agronomic Characters in Rapeseed (Brassica napus L.) 1. Genetic analysis for maturity, plant height and grain weight per plant. (유채의 실용형질에 대한 유전연구 -제 1 보 유채의 초장, 성숙기 및 종실중의 유전분석-)

  • Lee, J.I.;Kwon, B.S.;Chae, Y.A.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.29 no.1
    • /
    • pp.84-88
    • /
    • 1984
  • To obtain basic information on the breeding of early maturing, short plant height rapeseed varieties, the following 7 varieties, Isuzu, Miyuki, Norin 25, Rang, Yongdang, Cresus and Tower were used in diallel crosses in 1979. Maturing date, plant height and grain weight per plant for the parents, $F_1$'s and $F_2$'s of the 7 x 7 partial diallel crosses were measured in 1981 for analysis of their genetic behavior. The results obtained are summarized as follows: 1. The days to maturing of $F_1$'s showed complete dominance for early maturing, and both additive and dominance genetic variances were significant. Number of effective factors in $F_1$'s was 3, but in $F_2$'s was 1. The degree of dominance in $F_1$'s was partial, while in $F_2$'s was complete. Both broad and narrow sense herita-bilities in $F_1$'s was high, while in $F_2$'s was low. 2. Yield per plant in $F_2$'s was controlled by additive component of genetic variance only, but $F_1$'s was different. The degree of dominance in $F_1$'s was complete, while in $F_2$'s was partial. The direction of dominance showed almost complete dominance over high yield and three effective factors was estimated. Yield per plant was controlled by recessive genes. 3. The plant height was controlled by both dominance and additive variance. Dominance was directed toward tall plant height. Number of effective factors was 2, and broad and narrow sense heritability were high in the plant height.

  • PDF

A Decision-Making Model of Integrated Vertical and Horizontal Move Plan for Finishing Material in Righ-Rise Building Construction (고층건물공사 마감자재의 수직$\cdot$수평이동계획이 통합된 의사결정모델)

  • Ahn Byung-Ju;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.2 no.2 s.6
    • /
    • pp.47-58
    • /
    • 2001
  • Of all the site logistics technologies in high-rise building construction, both vertical and horizontal move plan, are the most imperative factors. And the horizontal plan follows lift-up plan as of the vertical plan. However though it may be, temporary lifts on site are numbered by heuristic formulas. The quantity of finishing material cannot be converted into lift-up load per finishing material. The lift-up plan cannot be evaluated the feasibility for finishing material move plan by a reasonable evaluation methodology. The horizontal plan is far from the vertical one. And the information as an input data for the horizontal plan is devoid of package unit size, length, and volume per finishing material. These can hardly result in reasonable and detail decision on how much to use temporary lifts, how long to use these, and where to deposit each finishing material. Therefore, this study is to suggest a decision-making model that can integrate vertical and horizontal material move plan in high-rise building construction and make a decision the plans systematically. And the study is to explain the concept, methodology, and contents of the model applied to a virtual project, named as MT 130 (Millennium Tower 130). By the model, the planner can shift his/her thinking framework on site logistics management products-oriented Into process-oriented. He/she can manage a project by the framework as system thinking, evaluate the feasibility of a lift-up plan, and decide the horizontal plan integrated with the lift-up.

  • PDF

Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator (선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.282-287
    • /
    • 2016
  • Recently in order to protect the ocean environment and to reduce energy consumption, shipbuilders have been developing highly economized ships. This research analyzed the possibility of adopting the onshore absorption refrigerator to offshore ships having a cooling system with refrigerant by using the waiste heat of the engine jacket cooling water instead of compression refrigerators. The results showed that R236fa could be a suitable medium for absorbing the heat of the absorber and condenser in an absorption refrigerator. The cooling system using R236fa achieved a high COP of 0.798, which is 15% and 5% higher than an air cooling system with a cooling tower and a water cooling system with a heat exchanger, respectively. The cooling system with R236fa achieved high efficiency with a 25% reduction in flow rate of LiBr solution and only 15.7% flow rate of cooling medium as compared to the water cooling system. The heating of sea water by the engine jacket water flowing out from the generator can prevent the crystallization of LiBr solution due to the low temperature of sea water.

A study on bicycle storage improvement in Seoul -Focusing on the bicycle storage in Seoul subway transit links- (서울시 자전거 보관소의 개선방안 -서울시 지하철 연계 환승 보관소를 중심으로-)

  • Park, Yeun-Kyung;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.405-411
    • /
    • 2016
  • Seoul city is publishing new plans to increase modal share rate of bicycle every year, such as, maintaining bicycle related facilities. But bicycle's modal share rate in Seoul stayed same for the last decade and people are still facing difficulties using bicycle related facilities. These problems are causing bicycle usage as connecting transportation of public transit to decrease. This study looked at the high bicycle modal countries, such as, Netherlands, Germany and Japan to find applicable solutions by analyzing cases and comparing them with cases of highly populated subway station of Sindorim in Seoul. For example, in Germany and Netherlands there is bicycle-parking system to help bikers to access subway easier, in Japan there is underground bicycle parking tower to safely keep high volume of bicycles with in small space. For Seoul city to increase its modal share rate, they should look at problems from users' prospective and solve it by fixing it and improving the services, not by making more facilities.

Biosorption of Pb and Cd by Indigenous Bacteria Isolated from Soil Contaminated with Oil and Heavy Metals (유류와 중금속으로 오염된 토양에서 분리한 미생물의 Pb와 Cd 생물흡착 특성)

  • Kim, Sang-Ho;Chon, Hyo-Taek;Lee, Jong-Un
    • Economic and Environmental Geology
    • /
    • v.42 no.5
    • /
    • pp.427-434
    • /
    • 2009
  • Indigenous bacterium which shows a tolerance to high metal toxicity was isolated from soil concomitantly contaminated with oil and heavy metals. The characteristics of the bacterium for Pb and Cd biosorption was investigated under the various experimental conditions such as bacterial growth phase, the initial metal concentration, the input biomass amount, temperature and pH. The Langmuir adsorption isotherm modeling was described to know the capacity and intensity of biosorption. The low initial concentration of heavy metals and high biomass has a maximum heavy metal removal efficiency, but biosorption capacity of Pb and Cd has different values. Biosorption efficiency was highest in the end of the microbial growth stage and under pH 5~9 condition, but was less affected by temperature variation of 25~$35^{\circ}C$. The maximum biosorption capacity for Pb and Cd was 62.11 and 192.31 mg/g, respectively and each $R^2$ was calculated as 0.71 and 0.98 by applying Langmuir isothermal adsorption equation. Biosorption for Cd was considered as monomolecular adsorption to single layer on the surface of cells, whereas biosorption for Pb was considered as accumulation process into the cell by the microbial metabolism and precipitation reaction with anion of bacteria.

Research and Development for Decontamination System of Spent Resin in Hanbit Nuclear Power Plant (한빛원전 폐수지 제염공정 개발연구)

  • Sung, Gi Hong
    • Journal of Radiation Industry
    • /
    • v.9 no.4
    • /
    • pp.217-221
    • /
    • 2015
  • When reactor coolant leaks occur due to cracks of a steam generator's tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000~7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In supercritical carbon dioxide method, we found that it also had a high decontamination efficiency. According to the results of these experiments, almost all decontamination method had a high efficiency, but considering the amounts of the secondary waste productions and work environment of the nuclear power plant, we judged the ultrasound and supercritical carbon dioxide method are suitable for application to the plant and we established the plant applicable decontamination process system on the basis of these two methods.

Study on the Air Insulation Design Guideline for ±500 kV Double Bipole Transmission Line with Metallic Return Conductor (도체귀로형 ±500 kV Double Bipole 송전선로 공기절연에 관한 연구)

  • Shin, Kooyong;Kwon, Gumin;Song, Seongwhan;Woo, Jungwook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.141-147
    • /
    • 2019
  • Recently, the biggest issue in the electricity industry is the increase in renewable energy, and various technologies are being developed to ensure the capacity of the power system. In addition, super-grids linking power systems are being pushed to utilize eco-friendly energy between countries and regions worldwide. The HVDC transmission technology is required to link the power network between regions with different characteristics of the power system such as frequency and voltage. Until now, Korea has applied HVDC transmission technology that connects mainland and Jeju Island with submarine cables. But, the HVDC transmission technology is still developing for long-distance high-capacity power transmission from power parks on the east coast to load-tight areas near the metropolitan area. Considering the high population density and mountainous domestic environment, it is pushing for commercialization of the design technology of the ${\pm}500kV$ Double Bipole with metallic return wire transmission line to transmit large-scale power of 8 GW using minimal right of ways. In this paper, the insulation characteristics were studied for the design of double-bipole transmission tower with metallic return wire, which is the first time in the world. And the air insulation characteristics resistant to the various overvoltage phenomena occurring on transmission lines were verified through a full-scale impulse voltage test.

Direction of Conservation and Management about Cultural Landscape of the Traditional Villages in Huizhou Region, China - Centered on IPA Analysis - (중국 휘주 지역 고촌락 문화경관 보전 관리 방안 - IPA 분석을 중심으로 -)

  • Zhang, Xiao Dong;Park, Jae Chul;Lin, Nan
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-75
    • /
    • 2019
  • The purpose of this study is to provide the conservation management direction about cultural landscape of the traditional villages in the area of Huizhou through the importance-performance analysis. The results of the survey on the importance - performance of 261 people who had many visits to various cultural landscapes of Huizhou villages such as Hongchun, Sidichun etc. are as follows. It was appeared that the item of 'good air' is the highest level of importance and satisfaction and is best condition. The item of 'historical conservation' is the high level of importance, but the level of satisfaction is low, so continuous improvement is necessary. The item of 'Old garden conservation' has high satisfaction but low importance, so it needs to improve its importance through subsequent improvement. The item of 'Keeping of old cemetary and old tower' has low importance and satisfaction but it is above average, so continuous maintenance is needed. The items of 'Preservation of stone gate' and 'Preservation of famous man's birth house' all have slightly higher satisfaction and lower importance. Both items are highly satisfied with their importance, so they should avoid excessive efforts and maintain the present status. Satisfaction with the item of 'water environment and water quality' was the lowest, and the problem of the present condition is the most serious, and a major improvement is needed. The importance and satisfaction of 'Commercial development of old villages' was the lowest among all items. This item is causing serious problems and should provide an overall improvement way to drastically improve the importance and satisfaction. Concentration is necessary to improve the environment of the whole villages, to protect the ecological plants and animals in old villages, to transfer and improve the culture of old villages, to maintain sustainability of the villages, and to protect old temple and old rock in old villages. As the level of satisfaction with sustainability is the lowest in the part of 'Concentrate here', there is a great concern about sustainability. Therefore, it is necessary to focus on sustainability and concentrate on sustainable development.

Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation (가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술)

  • Joo, Soobin;Lee, Sangmin;Kim, Hyungjun;Shim, Intae;Kim, Heejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.449-458
    • /
    • 2023
  • As an adsorption technology for dissolved organic matter, the adsorption capacity of granular activated carbon, GAC, can be applied, but activated carbon whose adsorption capacity is significantly reduced by use is inevitably replaced or regenerated. However, due to the economics of replacement cost, thermal regeneration method is used commercially, but high energy cost and loss of activated carbon occur under high temperature conditions above 800℃. In this study, the Sono-Fenton method, a multi-oxidation technology that combines Fenton oxidation and ultrasonic oxidation, was applied to improve the regeneration efficiency of spent GAC used to treat dissolved organic matter in combined sewer overflows (CSOs), and the regeneration efficiency of spent GAC by oxidant and ultrasonic frequency was investigated. In the applied Sono-Fenton treatment, the highest regeneration efficiency of 68.5% was obtained under the regeneration conditions of Fe2+ 10 mmol/L, H2O2 concentration 1,000 mmol/L, ultrasonic treatment time of 120 min, and ultrasonic frequency of 40 kHz. And similar efficiency was also obtained at 750 kHz, while ultrasonic waves of other frequencies had poor regeneration efficiency, and the magnitude of frequency and GAC regeneration efficiency did not show a linear relationship. In the case of continuous operation of the GAC adsorption tower with CSOs prepared by diluting raw sewage, about 700 hours of operation without regeneration was possible, and as a result of applying one Sono-Fenton treatment, 40-70% CODcr removal efficiency was obtained during a total of 1,000 hours of GAC adsorption operation.