• Title/Summary/Keyword: high temperature insulation

Search Result 483, Processing Time 0.032 seconds

Electrical Insulation Design of a 154 kV Class HTS Transformer (154 kV급 고온초전도 변압기의 전기절연 설계)

  • Cheon, H.G.;Kwag, D.S.;Choi, J.H.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.53-56
    • /
    • 2007
  • In the response to the demand for electrical energy, much effort was given to develop and commercialize high temperature superconducting (HTS) power equipment has been made around the world. Especially, a HTS transformer is one of the most promising devices. Recently, Korea Polytechnic University and Gyeongsang National University are developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects in Korea. For the development of 154 kV class HTS transformer, the cryogenic insulation technology should be established. We have been analyzed insulation composition and investigated electrical characteristics such as the breakdown of $LN_2$, barrier, kapton films, and the surface flashover of FRP in $LN_2$. Furthermore, we are going to compare with measured each value and apply the value to the most suitable insulating design of the HTS transformer.

A Study on Insulation Characteristics by Thickness of Laminated Polypropylene Paper for an HTS Transmission Cable (송전급 HTS 케이블용 반합성지의 두께에 따른 절연특성 연구)

  • Choi, Jin-Wook;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.35-38
    • /
    • 2009
  • The high temperature superconducting(HTS) power cable, as a key component of the next generation power transmission system, operates cost-effectively because of much less transmission loss. Currently, a world-wide research has been undertaken actively. In this research, we designed insulation thickness and investigated thickness effect of laminated polypropylene paper(LPP) which is insulation material of HTS cable in case of AC and impulse breakdown.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

A study on charging and electrical stability characteristics with no-insulation and metal insulation in form of racetrack type coils

  • Quach, Huu Luong;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.3
    • /
    • pp.13-19
    • /
    • 2020
  • This study presents the experiment and simulation results on the magnetic field response and electrical stability behaviors of no-insulation (NI) and metal insulation with stainless steel tape (MI-SS) which wound in form of racetrack type coils. First of all, the structural design of the racetrack type bobbin was shown along with its parameters. Then, the current-voltage tests were carried out to measure the critical current of both test coils. Also, the sudden discharging and charging tests were performed in the steady state to estimate the decay field time and magnetic field response, respectively. Finally, the overcurrent tests were conducted in the transient state to investigate the electrical stability of these test coils. Based on the experimental results, the contact surface resistances were calculated and applied to the field coils (FCs) of 10-MW-class second generation high temperature superconducting generator (2G HTSG) used in wind offshore environment. The charging delay time and electrical stability for NI and MI-SS HTS FCs of 10-MW-class 2G HTSG are analyzed by the equivalent circuit model and the key parameters which were obtained from the electromagnetic finite element analysis results.

Analyses of Energy Savings and Night Heating Performance of a Movable Thermal Insulation Shuttered Window (단열셔터를 적용한 구동창호의 에너지 절감 및 야간 난방성능 분석)

  • Lee, Jang-Man;Cho, Soo;Lim, Sang-Hoon;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.150-155
    • /
    • 2013
  • Usually, a window tends to have a lower thermal performance, than that of an ordinary wall. This study analyzes the enhancement of thermal performance of a window, when a Thermal Insulation Shutter is installed. The analyses were conducted at the laboratory, and with a full-scale mockup house, and the U-factor and heating load were examined. The laboratory results show that the U-factor increased by approximately 28%, when a Thermal Insulation Shutter was installed. The temperature difference was about $5^{\circ}C$, and this shows that the Thermal Insulation Shutter enhances the thermal performance of the window, when installed. The mockup house was used to calculate the heating load; the heating load was reduced by more than 41%, and shows that the installation of a Thermal Insulation Shutter is an effective way to reduce heating energy consumption.

Insulation Design and Test of Model Windings for the Development of High Temperature Superconducting Transformer (고온초전도변압기 개발을 위한 모델 권선의 절연 설계 및 평가)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kwak, Dong-Sun;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.19-22
    • /
    • 2003
  • In the response to increasing the demands for electrical energy, much effort aimed to develop and commercialize 1MVA HTS power equipments that is supported by a grant from center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program funded by the Ministry of Science and Technology is going on in Korea. For the development, the cryogenic insulation and winding insulation of it in this paper are discussed. In the first many types of dielectric insulating tests were carried out. In detail Breakdown characteristics of $LN_2$, FRP and turn insulating films, flashover characteristics along the FRP surface in $LN_2$ were verified after distinguishing insulation components in HIS windings. And then model windings were designed and insulation test was conducted. These included a AC withstand voltage test of 50kV rms and a lightning impulse test of 150kV at peak.

  • PDF

The Study on Treeing under the Temperature Variation in Low Density Polyethylene Mixed with Dodecyl Alcohol (Dodecyl Alcohol이 첨가된 P.E에서 온도변화에 따른 Treeing에 관한 연구)

  • Lee, Chang-Hee;Lee, Kye-An;Kim, Sang-Jun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.75-78
    • /
    • 1989
  • Insulation of P.E insulated cable under the field of high-voltage will be breakdown ultimately due to the degradation process called 'Treeing' which is generated in the insulation, so long as any counter-measure suppressing or eliminating it could not be provided. In this paper as a counter-measure Dodecyl Alcohol is mixed with P.E and Treeing under the temperature variation has been observed. Results show that the larger weight ratio of Dodecyl Alcohol is stronger the effect of suppressing Tree ing in the range from room temperature to 40$^{\circ}C$ and generated Treeing has been soon eliminated and it never again generated.

  • PDF

Temperature dependance of Dielectric strength in Nano-composites (Nano-composites 절연파괴강도의 온도의존성)

  • Lee, Kang-Won;Lee, Hyuk-Jin;Kim, Jong-Hwan;Shin, Jong-Yeol;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.256-257
    • /
    • 2008
  • Recently, with the increase of demand of electricity, electric cable or electric transfer machine are rapidly developed and meet the demand with the extra high voltage and massive capacity, the dangers of electrical accident of insulator are increasing by the electric stress, insulation degradation and insulation breakdown in insulator. In this paper, it is investigated that the temperature dependance of dielectric strength in nano-composites. We obtained that breakdown voltage of 0.4 [wt%] specimens is higher than the other $SiO_2$ content.

  • PDF

Analysis of Hygrothermal Performance of Wood Frame Walls according to Position of Insulation and Climate Conditions

  • Kang, Yujin;Chang, Seong Jin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.264-273
    • /
    • 2016
  • The insulation of a building envelope influences the hygrothermal performance as well as the thermal performance of the building. While most of Korean wood frame houses have an interior insulation system, the exterior insulation system with high thermal performance has recently been applied. While it can be effective in energy savings for better insulation performance, without consideration of the moisture, condensation and mould growth can occur. Therefore, in this study, hygrothermal behaviour, water content, and mould growth were analyzed using hygrothermal simulation of an exterior wall of a wood frame house with which the interior insulation and exterior insulation systems were applied. The wall layer included Wall A (Interior insulation) and Wall B (Exterior insulation). The U-values were identified as 0.173 and $0.157W/m^2K$, respectively. The total water content and OSB absolute water content of Wall A were confirmed to be higher than those of Wall B, but the absolute water content did not exceed the reference value of 20%. The moisture content of the two walls was determined to be stable in the selected areas. However, mould growth risk analysis confirmed that both Wall A and Wall B were at risk of mould growth. It was confirmed that as the indoor setting temperature decreased, the mould index and growth rate in the same area increased. Therefore, the mould growth risk was affected more by indoor and outdoor climate conditions than by the position of the insulation. Consequently, the thermal performance of Wall B was superior to that of Wall A but the hygrothermal performances were confirmed to be similar.

Research on Improvement of Efficiency in Flat Plate Solar Collector by Using Double-Wall Glazing and VIP Insulation (이중투과체 및 VIP복합 단열재 적용 평판 집열기의 성능 향상에 대한 연구)

  • Lee, Doo Ho;Jang, Han Bin;Kim, Young Hak;Do, Kyu Hyung;Lee, Kwang Seob;Lyu, Nam Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.458-465
    • /
    • 2016
  • The purpose of this research is to improve the thermal effiency of solar collector and to quantitatively analyze its performance. Solar thermal systems have been limited to water heating systems mainly using low-temperature range. However, through diverse developments, the application has been extended to medium- and high-temperature fields such as solar heating, solar air conditioning, and solar thermal industrial process. Among the diverse research, this research is specially focusing on enhancement of the thermal performance by minimizing the heat loss coefficient of flat plate solar collectors. In order to do it, a front-side glazing material and a back-side insulation material with high insulated structure is proposed and based on computational analysis, the performance of energy collecting volume of the proposed solar collector is analyzed. The research shows that the proposed structure has the excellent performance at medium- and high-temperature range. therefore, it is expected that the proposed structure can easily replace existing technologies.