• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.038 seconds

Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner (냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

Quality Attributes of Carrot Pieces for Baby Foods Prepared under Different Freeze Drying Conditions (냉동 건조 조건에 따른 이유식용 당근의 품질 특성)

  • Kim, Hye-Kyoung;Suh, Dong-Soon;Lee, Young-Chun;Kim, Kwang-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.799-804
    • /
    • 2002
  • Optimum conditions of freeze-dried carrots were determined using response surface methodology. Physicochemical and sensory properties of freeze-dried carrot prepared at different plate temperatures and chamber pressures were evaluated. Drying time increased with decreasing plate temperature and chamber pressure. Rehydration ratio decreased inversely with chamber pressure at low plate temperature, but increased proportionally with chamber pressure at high temperature. Density, color, and sensory off-flavor were not affected by the plate temperature and chamber pressure. Sensory color, tenderness, and carrot flavor increased with decreasing plate temperature, but were not affected by chamber pressure. Based on the drying time, rehydration ratio, and sensory attributes, optimum plate temperature and chamber pressure for the preparation of freeze-dried carrot were determined as $43^{\circ}C$ and 700 micronHg, respectively.

Pressure fluctuations of the hot cathode ionization gauges at the stainless steel high vacuum chamber according to room temperature variations (스테인레스 스틸 고진공용기에 부착된 열음극 전리진공게이지의 주변 온도변화에 따른 압력요동)

  • ;;;;Ichiro Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.54-58
    • /
    • 2004
  • Three hot cathode ionization gauges (HCIG) were used to study their responses of pressure measurements at the stainless steel high vacuum (HV) chamber around room temperatures. The pressure variations of HV measured by the three HCIGs between $20 ^{\circ}C$ and $26 ^{\circ}C$ were 5.0 %, 5.3 %, and 10.3 %, respectively. However, pressure differences between $21.5 ^{\circ}C$ and $22.5^{\circ}C$ were lower than the gauges uncertainty limits. The pressure variations of the HCIGs at the HV chamber was not directly affected by gauge characteristics, but pressure changes due to room temperatures.

Numerical study of the flow and heat transfer characteristics in a scale model of the vessel cooling system for the HTTR

  • Tomasz Kwiatkowski;Michal Jedrzejczyk;Afaque Shams
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1310-1319
    • /
    • 2024
  • The reactor cavity cooling system (RCCS) is a passive reactor safety system commonly present in the designs of High-Temperature Gas-cooled Reactors (HTGR) that removes heat from the reactor pressure vessel by means of natural convection and radiation. It is one of the factors responsible for ensuring that the reactor does not melt down under any plausible accident scenario. For the simulation of accident scenarios, which are transient phenomena unfolding over a span of up to several days, intermediate fidelity methods and system codes must be employed to limit the models' execution time. These models can quantify radiation heat transfer well, but heat transfer caused by natural convection must be quantified with the use of correlations for the heat transfer coefficient. It is difficult to obtain reliable correlations for HTGR RCCS heat transfer coefficients experimentally due to such a system's size. They could, however, be obtained from high-fidelity steady-state simulations of RCCSs. The Rayleigh number in RCCSs is too high for using a Direct Numerical Simulation (DNS) technique; thus, a Reynolds-Averaged Navier-Stokes (RANS) approach must be employed. There are many RANS models, each performing best under different geometry and fluid flow conditions. To find the most suitable one for simulating an RCCS, the RANS models need to be validated. This work benchmarks various RANS models against three experiments performed on the HTTR RCCS Mockup by the Japanese Atomic Energy Agency (JAEA) in 1993. This facility is a 1/6 scale model of a vessel cooling system (VCS) for the High Temperature Engineering Test Reactor (HTTR), which is operated by JAEA. Multiple RANS models were evaluated on a simplified 2d-axisymmetric geometry. They were found to reproduce the experimental temperature profiles with errors of up to 22% for the lowest temperature benchmark and 15% for the higher temperature benchmarks. The results highlight that the pragmatic turbulence models need to be validated for high Rayleigh natural convection-driven flows and improved accordingly, more publicly available experimental data of RCCS resembling experiments is needed and indicate that a 2d-axisymmetric geometry approximation is likely insufficient to capture all the relevant phenomena in RCCS simulations.

A study of improving filtration efficiency through SiC whisker synthesis on carbon felt by CVD VS method

  • Kim, Gwang-Ju;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.150-150
    • /
    • 2016
  • Mankind is enjoying a great convenience of their life by the rapid growth of secondary industry since the Industrial Revolution and it is possible due to the invention of huge power such as engine. The automobile which plays the important role of industrial development and human movement is powered by the Engine Module, and especially Diesel engine is widely used because of mechanical durability and energy efficiency. The main work mechanism of the Diesel engine is composed of inhalation of the organic material (coal, oil, etc.), combustion, explosion and exhaust Cycle process then the carbon compound emissions during the last exhaust process are essential which is known as the major causes of air pollution issues in recent years. In particular, COx, called carbon oxide compound which is composed of a very small size of the particles from several ten to hundred nano meter and they exist as a suspension in the atmosphere. These Diesel particles can be accumulated at the respiratory organs and cause many serious diseases. In order to compensate for the weak point of such a Diesel Engine, the DPF(Diesel Particulate Filter) post-cleaning equipment has been used and it mainly consists of ceramic materials(SiC, Cordierite etc) because of the necessity for the engine system durability on the exposure of high temperature, high pressure and chemical harsh environmental. Ceramic Material filter, but it remains a lot of problems yet, such as limitations of collecting very small particles below micro size, high cost due to difficulties of manufacturing process and low fuel consumption efficiency due to back pressure increase by the small pore structure. This study is to test the possibility of new structure by direct infiltration of SiC Whisker on Carbon felt as the next generation filter and this new filter is expected to improve the above various problems of the Ceramic DPF currently in use and reduction of the cost simultaneously. In this experiment, non-catalytic VS CVD (Vapor-Solid Chemical Vaporized Deposition) system was adopted to keep high mechanical properties of SiC and MTS (Methyl-Trichloro-Silane) gas used as source and H2 gas used as dilute gas. From this, the suitable whisker growth for high performance filter was observed depending on each deposition conditions change (input gas ratio, temperature, mass flow rate etc.).

  • PDF

Growth and characterizations of INAlAs epilayers and InGaAs/INAlAs quantum well structures by low pressure metalorganic chemical vapor deposition (저압 유기금속 화학증착법을 이용한 InAIAs 에피층과 InGaAs/InAIAs 양자 우물 구조의 성장과 분석)

  • 유경란;문영부;이태완;윤의준
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.328-333
    • /
    • 1998
  • Lattice-matched InAIAs epilayers were grown on (001) InP substrate by low pressure metalorganic chemical vapor deposition. The effects of growth conditions on the properties of InAIAs were analyzed, and InGaAs/InAIAs single and multiple quantum wells were successfully grown. It was observed that the optical property of InAIAs epilayers was improved in the temperature range of 620~$700^{\circ}C$ as the growth temperature increased due to the reduction of oxygen incorporation, however, the crystallinity decreased at temperatures higher than $750^{\circ}C$ due to the degraded crystallinity of the bufter layers. The enhanced incorporation of AI into epilayer was observed at high $AsH_3$flow rates and it was explained in terms of the differences in bond strengths of AI-As and In-As. The measured photoluminescence peak energies from InGaAs/InAIAs single quantum wells were consistent with the calculated ones based on transfer matrix method. High-order satellite peaks and fine thickness fringes were observed by high-resolution x-ray diffraction, implying that the high-quality multiple quantum wells with abrupt heterointerfaces were grown.

  • PDF

Comparison of Physicochemical Properties and Antioxidant Activity between Raw and Heat-Treated Vegetables (열처리한 채소류의 이화학적 특성 및 항산화 활성 비교)

  • Kim, So-Young;Lee, Young-Min;Kim, Jong-Bong;Park, Dong-Sik;Go, Jeong-Sook;Kim, Haeng-Ran
    • The Korean Journal of Community Living Science
    • /
    • v.25 no.1
    • /
    • pp.5-18
    • /
    • 2014
  • This study examines the changes in the physicochemical property and antioxidant activity of six types of vegetables (carrots, crown daisy, mugwort, cabbages, onions, and garlic) based on heat-treated cooking. According to the results, proximate contents (crude protein, fat, and ash) were lower in blanched samples than in untreated samples. Untreated cabbages showed the highest level of total dietary fiber content, which decreased by blanching and increased by high-temperature/high-pressure (HTHP) treatment. Noteworthy is that, in the case of soluble dietary fiber, blanched crown daisy and mugwort showed significantly high levels of 12.0 g and 7.3 g per 100 g(dry basis). There was no significant change in tocopherol content in heat-treated samples. The highest levels of total polyphenol and flavonoid content were 6.73 g and 5.51 g per 100 g, respectively, in the mugwort sample with HTHP treatment at $130^{\circ}C$ for 2 h. The water extract of mugwort with HTHP treatment had the strongest antioxidant effect based on three bioassays (SOD, DPPH, and ABTS). These results indicate the relative correlation between the level of physiologically active content and antioxidant activity and suggest new insights into ingredients for developing functional foods.

Etch Characteristics of $SiO_2$ by using Pulse-Time Modulation in the Dual-Frequency Capacitive Coupled Plasma

  • Jeon, Min-Hwan;Gang, Se-Gu;Park, Jong-Yun;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.472-472
    • /
    • 2011
  • The capacitive coupled plasma (CCP) has been extensively used in the semiconductor industry because it has not only good uniformity, but also low electron temperature. But CCP source has some problems, such as difficulty in varying the ion bombardment energy separately, low plasma density, and high processing pressure, etc. In this reason, dual frequency CCP has been investigated with a separate substrate biasing to control the plasma parameters and to obtain high etch rate with high etch selectivity. Especially, in this study, we studied on the etching of $SiO_2$ by using the pulse-time modulation in the dual-frequency CCP source composed of 60 MHz/ 2 MHz rf power. By using the combination of high /low rf powers, the differences in the gas dissociation, plasma density, and etch characteristics were investigated. Also, as the size of the semiconductor device is decreased to nano-scale, the etching of contact hole which has nano-scale higher aspect ratio is required. For the nano-scale contact hole etching by using continuous plasma, several etch problems such as bowing, sidewall taper, twist, mask faceting, erosion, distortions etc. occurs. To resolve these problems, etching in low process pressure, more sidewall passivation by using fluorocarbon-based plasma with high carbon ratio, low temperature processing, charge effect breaking, power modulation are needed. Therefore, in this study, to resolve these problems, we used the pulse-time modulated dual-frequency CCP system. Pulse plasma is generated by periodical turning the RF power On and Off state. We measured the etch rate, etch selectivity and etch profile by using a step profilometer and SEM. Also the X-ray photoelectron spectroscopic analysis on the surfaces etched by different duty ratio conditions correlate with the results above.

  • PDF

Identification of High Pressure-High Temperature Treated Gem Diamonds using a Micro-Raman Spectroscopy (고압고온 처리된 보석용 다이아몬드의 마이크로라만 분석에 의한 감별 연구)

  • Song, Oh-Sung;Kim, Jong-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.817-822
    • /
    • 2006
  • Diamonds have been widely employed as polishing media for precise machining and noble substrates for microelectronics. The recent development of the split sphere press has led to the enhancement of low quality natural diamonds. Synthesized and treated diamonds are sometimes traded deceptively as high quality natural diamonds because it is hard to distinguish among these diamonds with conventional gemological characterization method. Therefore, we need to develop a new identification method that is cheap, fast, and non-destructive. We proposed using a new method of micro-Raman spectroscopy for checking the local HPHT residual stress to distinguish these diamonds from natural ones. We observe unique ~10f compressive and tensile strains at Type I and Type II diamonds after HPHT treatment. Our result implies that our proposed methods may be appropriate fur identification of the treated diamonds with appropriate reference samples.

  • PDF

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • Im, Yu-Bong;Choe, Won-Ho;Lee, Seung-Hun;Han, U-Yong;Lee, Jong-Hyeon;Lee, Sang-Gyun;Ha, Jeong-Min;Kim, Jong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF