• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.036 seconds

The Analysis of Thermal Conductivity and Basic Quality Performances of Decoration Wood-based Flooring Board Laminated with PVC Surface Decoration Materials (PVC 표면치장재를 적층한 치장목질마루판의 열특성 및 기초 품질성능 분석)

  • Park, Cheul-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.53-60
    • /
    • 2018
  • For test on flooring board laminated with PVC decoration materials in order to replace the current surface materials such as HPL in decoration wood-based flooring board. the Results of comparison and analysis are as follows: For thermal conductivity, flooring board decorated with PVC did not show huge differences when temperature was rising and lowering compared to the flooring materials laminated with the existing HPL surface materials. It seems the most meaningful results for using it as indoor flooring materials. That is, in Korea where there is the culture focusing on ondol heating, use amount of heat energy and efficiency of flooring materials are very important and sensitive issues, involving immediately with household economy of final consumers, and it might be a criteria to judge basic performances required as flooring materials. As a result of the analysis on mandatory durability test items such as abrasion resistance, absorption width expansion rate, impact resistance, surface hardness, and impact absorption for flooring materials, compared to flooring board laminated with general HPL surface decoration materials, decoration wood-based flooring board laminated with PVC surface decoration materials which is higher abrasion resistance with smaller transformation and has better durability and impact absorption of the surface, is available for actual application as indoor flooring board, and for replacing surface decoration materials impregnated with heat-hardened resion such as HPL.

A Research on the Development of Smartwatch and Wind Speed System for Marine Leisure (해양레저용 스마트워치 및 풍향풍속계 개발에 관한 연구)

  • Ha, Yeon-Chul;Park, Jae-Mun;Lee, In-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.20-29
    • /
    • 2021
  • This study developed a smartwatch and a wind speed system in accordance with the necessity of a device that provides the information required in marine leisure. Based on a marine leisure smartwatch with a multi-sensor, a gyro box, and a wind speed system, external data such as GPS, motion, humidity, temperature, air pressure, and heart rate can be collected. In addition, the collected external environment data can be managed through an application on a smartphone, which is an Android-based mobile device. The developed smartwatch and wind speed system are expected to contribute to increasing accessibility and revitalization of the marine leisure industry. In addition, in terms of safety and education, the need for a device that provides marine information is large, so it is expected to increase the possibility of entering the high value-added market and improve the product localization rate.

Part 4. Clinical Practice Guideline for Surveillance and Imaging Studies of Trauma Patients in the Trauma Bay from the Korean Society of Traumatology

  • Chang, Sung Wook;Choi, Kang Kook;Kim, O Hyun;Kim, Maru;Lee, Gil Jae
    • Journal of Trauma and Injury
    • /
    • v.33 no.4
    • /
    • pp.207-218
    • /
    • 2020
  • The following recommendations are presented herein: All trauma patients admitted to the resuscitation room should be constantly (or periodically) monitored for parameters such as blood pressure, heart rate, respiratory rate, oxygen saturation, body temperature, electrocardiography, Glasgow Coma Scale, and pupil reflex (1C). Chest AP and pelvic AP should be performed as the standard initial trauma series for severe trauma patients (1B). In patients with severe hemodynamically unstable trauma, it is recommended to perform extended focused assessment with sonography for trauma (eFAST) as an initial examination (1B). In hemodynamically stable trauma patients, eFAST can be considered as the initial examination (2B). For the diagnosis of suspected head trauma patients, brain computed tomography (CT) should be performed as an initial examination (1B). Cervical spine CT should be performed as an initial imaging test for patients with suspected cervical spine injury (1C). It is not necessary to perform chest CT as an initial examination in all patients with suspected chest injury, but in cases of suspected vascular injury in patients with thoracic or high-energy damage due to the mechanism of injury, chest CT can be considered for patients in a hemodynamically stable condition (2B). CT of the abdomen is recommended for patients suspected of abdominal trauma with stable vital signs (1B). CT of the abdomen should be considered for suspected pelvic trauma patients with stable vital signs (2B). Whole-body CT can be considered in patients with suspicion of severe trauma with stable vital signs (2B). Magnetic resonance imaging can be considered in hemodynamically stable trauma patients with suspected spinal cord injuries (2B).

Design and Implementation of an Indoor Particulate Matter and Noise Monitoring System (실내 미세먼지 및 소음 모니터링 시스템 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • As the COVID-19 pandemic situation worsens, the time spent indoors increases, and the exposure to indoor environmental pollution such as indoor air pollution and noise also increases, causing problems such as deterioration of human health, stress, and discord between neighbors. This paper designs and implements a system that measures and monitors indoor air quality and noise, which are representative evaluation criteria of the indoor environment. The system proposed in this paper consists of a particulate matter measurement subsystem that measures and corrects the concentration of particulate matters to monitor indoor air quality, and a noise measurement subsystem that detects changes in sound and converts it to a sound pressure level. The concentration of indoor particulate matters is measured using a laser-based light scattering method, and an error caused by temperature and humidity is compensated in this paper. For indoor noise measurement, the voltage measured through a microphone is basically measured, Fourier transform is performed to classify it by frequency, and then A-weighting is performed to correct loudness equality. Then, the RMS value is obtained, high-frequency noise is removed by performing time-weighting, and then SPL is obtained. Finally, the equivalent noise level for 1 minute and 5 minutes are calculated to show the indoor noise level. In order to classify noise into direct impact sound and air transmission noise, a piezo vibration sensors is mounted to determine the presence or absence of direct impact transmitted through the wall. For performance evaluation, the error of particulate matter measurement is analyzed through TSI's AM510 instrument. and compare the noise error with CEM's noise measurement system.

Modification of an LPG Engine Generator for Biomass Syngas Application (바이오매스 합성가스 적용을 위한 LPG 엔진발전기 개조 및 성능평가)

  • Eliezel, Habineza;Hong, Seong Gu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.5
    • /
    • pp.9-16
    • /
    • 2022
  • Syngas, also known as synthesis gas, synthetic gas, or producer gas, is a combustible gas mixture generated when organic material (biomass) is heated in a gasifier with a limited airflow at a high temperature and elevated pressure. The present research was aimed at modifying the existing LPG engine generator for fully operated syngas. During this study, the designed gasifier-powered woodchip biomass was used for syngas production to generate power. A 6.0 kW LPG engine generator was modified and tested for operation on syngas. In the experiments, syngas and LPG fuels were tested as test fuels. For syngas production, 3 kg of dry woodchips were fed and burnt into the designed downdraft gasifier. The gasifier was connected to a blower coupled with a slider to help the air supply and control the ignition. The convection cooling system was connected to the syngas flow pipe for cooling the hot produce gas and filtering the impurities. For engine modification, a customized T-shaped flexible air/fuel mixture control device was designed for adjusting the correct stoichiometric air-fuel ratio ranging between 1:1.1 and 1.3 to match the combustion needs of the engine. The composition of produced syngas was analyzed using a gas analyzer and its composition was; 13~15 %, 10.2~13 %, 4.1~4.5 %, and 11.9~14.6 % for CO, H2, CH4, and CO2 respectively with a heating value range of 4.12~5.01 MJ/Nm3. The maximum peak power output generated from syngas and LPG was recorded using a clamp-on power meter and found to be 3,689 watts and 5,001 watts, respectively. The results found from the experiment show that the LPG engine generator operated on syngas can be adopted with a de-ration rate of 73.78 % compared to its regular operating fuel.

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.

Effects of Surface Roughness on the Performance of a Gas Foil Thrust Bearing (표면 거칠기가 가스 포일 스러스트 베어링의 성능에 미치는 영향)

  • Sung Ho Hwnag;Dae Yeon Kim;Tae Ho Kim
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.81-85
    • /
    • 2023
  • This study presents an experimental investigation of the effects of surface roughness on gas foil thrust bearing (GFTB) performance. A high-speed motor with the maximum speed of 80 krpm rotates a thrust runner and a pneumatic cylinder applies static loads to the test GFTB. When the motor speed increases and reaches a specific speed at which a hydrodynamic film pressure generated within the gap between the thrust runner and test GFTB is enough to support the applied static load, the thrust runner lifts off from the test GFTB and the friction mechanism changes from the boundary lubrication to the hydrodynamic lubrication. The experiment shows a series of lift-off test and load-carrying capacity test for two thrust runners with different surface roughnesses. For a constant static load of 15 N, thrust runner A with its lower surface roughness exhibits a higher start-up torque but lower lift-off torque than thrust runner B with a higher surface roughness. The load capacity test at a rotor speed of 60 krpm reveals that runner A results in a higher maximum load capacity than runner B. Runner A also shows a lower drag torque, friction coefficient, and bearing temperature than runner B at constant static loads. The results imply that maintaining a consistent surface roughness for a thrust runner may improve its static GFTB performance.

Understanding Physical Mechanism of 2022 European Heat Wave (2022년 발생한 기록적인 유럽 폭염 발생의 역학적 원인 규명 연구)

  • Ju Heon Kim;Gun-Hwan Yang;Hyun-Joon Sung;Jung Hyun Park;Eunkyo Seo
    • Atmosphere
    • /
    • v.33 no.3
    • /
    • pp.307-317
    • /
    • 2023
  • This study investigates the physical mechanisms that contributed to the 2022 European record-breaking heatwave throughout May-August (MJJA). The European climate has experienced surface warming and drying in the recent decade (1979~2022) which influences the development of the 2022 European heatwave. Since its spatial pattern resembles the 2003 European heatwave which is a well-known case developed by the strong coupling of near-surface conditions to land surface processes, the 2022 heatwave is compared with the 2003 case. Understanding heatwave development is carried out by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis version 5 (ERA5) and daily maximum surface temperature released by NCEP (National Centers for Environmental Prediction) CPC (Climate Prediction Center). The results suggest that the persistent high pressure along with clear sky tends to increase the downward shortwave radiation which leads to enhanced sensible heat flux with the land surface dryness. Terrestrial Coupling Index (TCI), a process-based multivariate metric, is employed to quantitatively measure segmented feedback processes, separately for the land, atmosphere, and two-legged couplings, which appears to the development of the 2022 heatwave, can be viewed as an expression of the recent trends, amplified by internal land-atmosphere interactions.

Influencing factors for Sleep Disturbance in the Intensive Care Unit Patients: A Systematic Review (중환자실 환자의 수면에 영향을 미치는 요인: 체계적 고찰)

  • Cho, Young Shin;Joung, Sunae
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : Sleep disturbances in patients in the intensive care unit (ICU) are related to health problems after discharge. Therefore, active prevention and management are required. Hence, identification of the factors that affect sleep in patients who are critically ill is necessary. Methods : The PubMed, Cochrane Library, CINAHL, EMBASE, and Web of Science databases were searched. Selection criteria were observational and experimental studies that assessed sleep as an outcome, included adult patients admitted to the ICU, and published between November 2015 and April 2022. Results : A total of 21,136 articles were identified through search engines and manual searches, and 42 articles were selected. From these, 22 influencing factors and 11 interventions were identified. Individual factors included disease severity, age, pain, delirium, comorbidities, alcohol consumption, sex, sleep disturbance before hospitalization, chronic obstructive pulmonary disease (COPD), cardiovascular disease, and high diastolic blood pressure (DBP), low hemoglobin (Hb), and low respiratory rate (RR). Environmental factors included light level, noise level, and temperature. Furthermore, treatment-related factors included use of sedatives, melatonin administration, sleep management guidelines, ventilator application, nursing treatment, and length of ICU stay. Regarding sleep interventions, massage, eye mask and earplugs, quiet time and multicomponent protocols, aromatherapy, acupressure, sounds of the sea, adaptive intervention, circulation lighting, and single occupation in a room were identified. Conclusion : Based on these results, we propose the development and application of various interventions to improve sleep quality in patients who are critically ill.

A study on the growth and properties of KTP single crystals (II) ($KTP(KTiOPO_4)$ 단결정 육성 및 물성 연구 (제2보))

  • Lee, M.J.;Cha, Y.W.;Orr, K.H.;Kim, P.C.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.3
    • /
    • pp.223-229
    • /
    • 1994
  • $KTP(KTiOPO_4)$ single crystals have been hydrothermally grown in KOH solutions. Properties and Raman spectra of grown crystal were investigated. The most effective solvents for the crystal growth of KTP were KOH and KF solutions. In this study, the properties of KTP single crystals grown hydrothermally at $500^{\circ}C$ in 9 m KOH solution were measured. The following results were obtained : lattice parameters ; a=1.281 nm and c=1.058 nm, density ; $2.94 g/cm^3$, Vickers hardness ; $562kg/cm^2$, refractive indices ; $n_e=1.740$ and $n_e= 1.747.$ And Raman spectra of hydrothermal growth KTP single crystal have been investigated at room temperature under atmospheric pressure. As a result, the $A_1$ modes agree very well with KTP single crystal of high temperatures solution growth but the behavior of $B_2$ modes were slightly different.

  • PDF