• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.035 seconds

An Ultrasonic Application with High Frequency for the Efficiency Elevation of the Hydrogen Fuel Production (On the Pole Interval and the Temperature) (수소연료 생산의 효율향상을 위한 고주파수 초음파 응용 (극간격과 온도 중심으로))

  • Song, Min-Geun;Son, Seung-Woo;Ju, Eun-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • A Study on the application of ultrasonic with high frequency is carried out as a plan to rise the efficiency of the hydrogen fuel production in an electrolysis of water. KOH is selected as an electrolyte and concentrations are 0 %, 10 %, 20 %, and 30%. The solvent is city water. A measurable device of buoyancy by an electronic balance and a measurable device of voltage with a sensor of pressure are planned newly as a measuring device to measure the quantity of hydrogen production. An ultrasonic transducer with high frequency of 2 MHz is selected to give them the ultrasonic forcing. In results, it is clarified that ultrasonic influences the decrease of overpotential in the electrolytic solution. And basic data according to the pole interval and the temperature are obtained.

A Study on the Stable Operation of High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 안정적 운영에 관한 연구)

  • Cho, Haejin;Na, Chanwook;Ko, Sungho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2017
  • Sodium hypochlorite, used as water disinfectant, is generated by electrolysis of salt. Compared to chlorine gas disinfection, it is free from high-pressure gas regulation and does not generate toxic gas, so it is increasingly used as a safe disinfectant. Despite these advantages, the concentration of sodium hypochlorite decreases with temperature during long-term storage, and the amount of chlorate increases when a large amount is added, it has mainly been applied to small-scale waterworks. To solve this problem, high sodium hypochlorite generation was developed. In this study, the changes of concentration and chlorate of sodium hypochlorite with time has been studied. As a result of the test, it was found that the usable period of sodium hypochlorite produced at a certain temperature or less was increased from 1.5 days to 13 days. Overall, sodium hypochlorite can be applied even in large-scale waterworks, which makes operation more stable and also reduces the disinfection byproducts, thus it contributed greatly to securing water quality.

A Numerical Study on Flow and Heat Transfer Characteristics of Supersonic Second Throat Exhaust Diffuser for High Altitude Simulation (고고도 모사용 초음속 이차목 디퓨저의 유동 및 열전달 특성에 대한 수치적 연구)

  • Yim, Kyungjin;Kim, Hongjip;Kim, Seunghan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.70-78
    • /
    • 2014
  • A numerical study has been conducted to investigate flow and heat transfer characteristics of supersonic second throat exhaust diffusers for high altitude simulation. By changing pressure and configuration, flow and cooling characteristics of the diffuser have been studied. At the normal operation of the diffuser, there were high temperature regions over 3,000 K without cooling, especially near wall and in subsonic diffuser part. If the cooling system of the diffuser is added, flow velocity is increased due to the cooled wall temperature.

Fabrication of High Break-down Voltage MIM Capacitors for IPD Applications

  • Wang, Cong;Kim, Nam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.241-241
    • /
    • 2009
  • For the Radio Frequency Integrated Passive Device (RFIPD) application, we have successfully developed and characterized high break-down voltage metal-insulator-metal (MIM) capacitors with 2,000 ${\AA}$ plasma-enhanced chemical vapor deposition (PECVD) silicon nitride which deposited with $SiH_4/NH_3$ gas mixing rate, working pressure, and RF power of PECVD at $250^{\circ}C$ chamber temperature. At the PECVD process condition of gas mixing rate (0.957), working pressure (0.9 Torr), and RF power (60 W), the AFM RMS value of about 2,000 ${\AA}$ silicon nitride on the bottom metal was the lowest of 0.862 nm and break-down electric field was the highest of about 8.0 MV/cm with the capacitance density of 326.5 $pF/mm^2$.

  • PDF

A Study on the Mechanical Behavior of Welded Parts in Thick Plate during Post Welding Heat Treatment (厚板熔接部의 應力除去 熱處理時의 力學的 擧動에 關한 硏究)

  • 방한서
    • Journal of Welding and Joining
    • /
    • v.11 no.4
    • /
    • pp.103-111
    • /
    • 1993
  • Recently, several high-tensile steels(e.g. 80kg and above, $2^{1/4}Cr$-1Mo)having good quality to high temperature and pressure-resistance are widely used to construct petroleum-plant and pressure vessel of heat or nuclear-power plant. However, in the steels, reheating crack at grain boundaries of the heat affected zone(HAZ) occures during post welding heat treatment(PWHT)to remove welding residual stress. In order to study theoretically the characteristics of reheating crack created by PWHT, the computer program of three-dimensional thermal-elasto-plasto-creep analysis based on finite element method are developed, and then the mechanical behavior(history of creep strain accumulation and stress relaxation, etc)of welded join in thick plate during PWTH is clarified by the numerical results.

  • PDF

Development of cryogenic liquid-vapor separator and liquid-level meter operating under high pressure condition (고압 상황에서 작동되는 극저온 기액 분리기와 액체 계면 측정기의 개발)

  • Lee, Cheon-Kyu;Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.51-55
    • /
    • 2011
  • In this study, the liquid-vapor (L-V) separator equipped with liquid-level meter is developed. In the developed L-V separator, the flange is designed to be attachable so that the separator can be flexibly applied under any cases where the volumetric of L-V separator is varied by the system requirement. The leak-tightness between the attachable flange and the chamber is experimentally confirmed with the use of double groove indium wire sealing even under the high pressure up to 20 bar. In addition, the liquid-level meter is designed and fabricated to figure out the inner state of L-V separator. It consists with 19 carbon composition resistors in series. All resistors are separately calibrated in the temperature range from 77 K to 200 K. The performance of the L-V separator and the liquid-level meter is investigated with experimental tests, and the result is presented in this paper.

Development of Hot Hydrostatic Extruder for Fine Wire and Tube (극세선 및 미세 튜브 압출 장치 개발)

  • Na K. H.;Park H. J.;Kim S. S.;Yun D. J.;Choi T. H.;Kim E. Z.;Cho N. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.05a
    • /
    • pp.239-244
    • /
    • 2001
  • Hot hydrostatic extruder was developed. The main objective of the development is forming fine wire and tube. On account of effectiveness and high performance, the extruder was designed to have double action. Therefore the main cylinder and mandrel can be driven independently. To cope with severe condition of high temperature and pressure, wire-wound container equipped with heater was used. Sealing technique also is important in this process, so seal ring was made of super-elastic metal. Another key for successful forming is choice of proper pressure medium. Fine wire and tube produced by the extruder can be used in semiconductor industry and medicine.

  • PDF

Effect of Compression Ratio on the Combustion Characteristics of a Thermodynamics-Based Homogeneous Charge Compression Ignition Engine

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.61-66
    • /
    • 2015
  • Homogeneous charge compression ignition (HCCI) engine combines the combustion characteristics of a compression ignition engine and a spark ignition engine. HCCI engines take advantage of the high compression ratio and heat release rate and thus exhibit high efficiency found in compression ignition engines. In modern research, simulation has be come a powerful tool as it saves time and also economical when compared to experimental study. Engine simulation has been developed to predict the performance of a homogeneous charge compression ignition engine. The effects of compression ratio, cylinder pressure, rate of pressure rise, flame temperature, rate of heat release, and mass fraction burned were simulated. The simulation and analysis show several meaningful results. The objective of the present study is to develop a combustion characteristics model for a homogeneous charge compression ignition engine running with isooctane as a fuel and effect of compression ratio.

Development of Electro-Mechanical Ignition Safety Device (전기-기계식 점화안전장치 개발)

  • Jang, Seung-Gyo;Kang, Ho-Joon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.332-335
    • /
    • 2011
  • Electro-Mechanical Ignition Safety Device(EMISD) for solid rocket motor is designed and manufactured. The EMISD utilizes a true rotary solenoid for arming mechanism and an electric squib(initiator) for generating ignition energy. In order to prove the ignition capability of the EMISD, 10-cc Closed Bomb Test(CBT) is performed, which measures the pressure built by high temperature and high pressure gas generated by operating EMISD.

  • PDF

A Study on the Relief of Shell Wall Thinning of Low Pressure Type Feedwater Heater Around the Extraction Nozzle Identified (저압형 급수가열기 추기노즐에서 동체 감육 완화에 관한 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Seo, Hyuk-Ki
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.173-179
    • /
    • 2008
  • The current machinery and tools of secondary channel of the nuclear power plants were produced in the carbon-steel and low-alloy steel. What produced with the carbon-steel occurs wall thinning effect from flow accelerated corrosion by the fluid flow at high temperature, high pressure. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed. Wall thinning by flow accelerated corrosion occurs piping system, the heat exchanger, steam condenser and feedwater heaters etc,. Feedwater heaters of many nuclear power plants have recently experienced sever wall thinning damage, which will increase as operating time progress. This study describes the comparisons between the numerical results using the FLUENT code and experimental data of down scale model.

  • PDF