• 제목/요약/키워드: high temperature air

검색결과 3,182건 처리시간 0.029초

잔디밭에서 기온과 이산화탄소 농도의 연직 변동 분석 (Vertical Variations Analysis of Air Temperature and CO2 Concentration in the Grassplots)

  • 소윤환;강동환;김일규;김병우;윤환진;김시현;손용석;신정현;안정우
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.147-157
    • /
    • 2017
  • This study investigated the characteristics of variations in carbon dioxide concentration and air temperature with the vertical change of surface in a grassplot. Field observations were carried out at a grassplot in Gyeongnam Science High School, over four days in August and November, 2015. Continuous observation equipment (GMP343, VAISALA) was installed at the LP (0.1 m from the surface) and UP (1.1 m from the surface) points, and the carbon dioxide concentration and air temperature were measured simultaneously at 1-min intervals. To summarize the results of the observation, August had higher than average concentrations of carbon dioxide, while November showed average air temperatures. Moreover, the concentration of carbon dioxide was higher at the UP point, while the air temperature was higher at the LP point. The correlation coefficient of carbon dioxide concentration between the UP and LP points was 0.80 in August across all the four days, while it was higher in November at 0.58-0.95. The results of the regression analysis of carbon dioxide concentration with air temperature changes for both August and November showed a distinct change at the LP point (R2=0.36-0.76), as compared to the UP point (R2=0.1-0.57). Between the UP and LP points, the carbon dioxide concentration and air temperature regression analysis results indicated that an active exchange was taking place between the two points.

하계에 도심지에서 관측된 흑구온도의 특성 분석 (On the Characteristics of Globe Temperature Variation Observed at Downtown in Summer Season)

  • 박종길;정우식;김석철;박길운
    • 한국환경과학회지
    • /
    • 제17권8호
    • /
    • pp.907-918
    • /
    • 2008
  • In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.

고온고속류에서 기화를 고려한 연료액적의 분열(Breakup)기구 해석에 관한 연구 (A Study on Analysis of Breakup Mechanism of Vaporizing Fuel Droplet in High Temperature and Velocity Air Stream)

  • 김관철;황상순
    • 한국분무공학회지
    • /
    • 제3권3호
    • /
    • pp.1-13
    • /
    • 1998
  • In this study, an experimental study was performed to investigate the breakup mechanism of vaporizing droplet. A well-controlled experimental apparatus was used to study breakup mechanisms of a monodisperse stream of drops injected into a transverse high temperature and velocity air stream. The experiments gave information$ about the microscopic structure of the liquid drop breakup process, drop breakup regimes, and drop trajectories in high temperature flow region. The breakup time, drop acceleration and wavelength of surface instability wave were measured from a high-magnification and double spark photography. The two instability theories, i.e., Kelvin-Helmholtz instability and Rayleigh-Taylor instability, were estimated by comparing the calculated data with the measurements. The results showed that the breakup time in high temperature flow condition is shortened because the surface tension is decreased by the increase of gas temperature.

  • PDF

AirSim을 이용한 화력발전소 고온 환경의 보일러 내부 점검용 드론 개발 및 검증을 위한 시뮬레이션 (Simulation for Development and Validation of Drone for Inspection Inside Boilers in High Temperature Thermal Power Plants Using AirSim)

  • 박상규;정진석;시하영;강범수
    • 한국항공우주학회지
    • /
    • 제49권1호
    • /
    • pp.53-61
    • /
    • 2021
  • 본 논문은 고온 환경의 화력발전소 보일러 내부 점검용 드론 개발을 위한 선행연구로 AirSim을 이용한 고온 환경에서의 시뮬레이션을 통해 드론이 정상적인 비행이 가능한지 검증 하였다. 고온의 비행 환경에서는 공기 밀도, 점성계수 등이 상온과 달라 공력특성이 달라지며 이에 따라 드론의 비행성능 또한 달라진다. 따라서 온도 변화에 따른 프로펠러의 공력 특성의 변화를 확인하기 위해 JBLADE를 통한 프로펠러 해석과 추력 테스트, 전기추진계통 성능예측모델을 통한 동작특성예측을 수행하였다. 그리고 해석 및 성능예측 결과를 AirSim에 적용해 시뮬레이션을 진행하고 결과 분석을 통해 기체 재설계를 진행하였다. 재설계 결과 80℃의 환경에서 호버링 시 필요한 추력을 얻기 위해 재설계 전 최대 출력의 약 65% 사용하던 것이 52%로 감소함을 확인하였다.

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

수도권지역 대기질 예측을 위한 기상장 모델의 바람장과 온도장 비교 연구 (Intercomparison of Wind and Air Temperature Fields of Meteorological Model for Forecasting Air Quality in Seoul Metropolitan Area)

  • 정주희;김유근;문윤섭;황미경
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.640-652
    • /
    • 2007
  • The MM5, RAMS and WRF, meteorological models have provided the dynamical parameters as inputs to air quality model. A major content of this study is that significant characteristics of three models for high-ozone occurrence analyze for surface wind and air temperature fields and compare with observation data in Seoul metropolitan area. An analysis of air temperature field revealed that location of core in high temperature of MM5 and WRF differed from that of RAMS. MM5 and WRF indicated high temperature in Seoul but RAMS represented it on the outskirts of Seoul. MM5 and WRF were underestimated maximum temperature during daytime but RAMS simulated similar value with observation data. Surface wind field with three models, it was shown many differences at horizontal distribution of wind direction. RAMS indicated weak wind speed in land and strong sea breeze at coastal areas than MM5 and WRF. However wind speed simulated by three model were overestimated during both daytime and nighttime.

냉각공기 유속 측정에 기반한 철도차량용 공기압축기 열교환기의 열전달 특성 분석 (Heat Transfer Analysis of a Heat Exchanger for an Air-Compressor of a Railway Vehicle Based on Cooling Air Flow Measurement)

  • 안준;김무선;장성일
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.447-454
    • /
    • 2017
  • In this study, local velocity distribution of cooling air in a heat exchanger used in an air compressor for a railway car was measured and heat transfer characteristics of the heat exchanger were analyzed. First, heat transfer coefficient and fin performance of the cooling air side were predicted and was checked if the fin of the heat exchanger was effectively used. Distribution of air flow rate at high temperature side was predicted through pipe network analysis and heat resistance at high temperature and low temperature side were predicted and compared. Spatial distribution of temperature in the interior and surface of the square channel constituting high-temperature side was predicted and appropriateness of the size of the heat exchanger was examined. As a result of the analysis, the present size of the heat exchanger could be reduced and it could be effective to promote heat transfer inside the heat exchanger rather than outside to improve performance of the heat exchanger.

시료 두께에 의한 저온진공건조기의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of the Low Temperature Vacuum Dryer by Material Layers)

  • 최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.226-232
    • /
    • 2002
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects ; (1)much energy loss happens due to the discharge of hot air during the drying process, (2)control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3)high temperature of floods in drying process brings about the production of low-grade drying products. Also, the hot-air drying method is inducing environmental and sanitary problems which are resulting from the emission of high temperature and high humidity air, including stick on the drying progress. Vacuum drying technique, whose drying time and 7uantity of exhausting energy is about 1/3 ~1/4 of hot air drying, is very excellent in the drying efficiency. As the results, it took about 20 hours for material to reach about 18% of the final moisture content in order to store products for a long time, from about 470% of the early moisture content at the beginning of drying, and maximum drying rate comes to about $0.35 kg/m^2hr$ at about 350% of the moisture content.

열교환기를 이용한 저온 환경 구축에 대한 기초 연구 (A Preliminary Study of Low Temperature Condition by Heat Exchanger)

  • 이양석;양재준;김유;고영성;임병준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.23-26
    • /
    • 2007
  • 본 연구에서는 고공 환경을 모사하기 위해 선행되어야 할 저온 환경 구축에 대한 기초 실험을 수행하였다. 열교환기를 이용하여 공기를 극저온으로 냉각 시키고, 상온의 공기를 혼합하여 온도 특성을 고찰하였다. 오리피스를 사용하여 각각의 유량을 제어할 수 있는 시스템을 구축하였으며, 열교환을 위하여 액체질소를 사용하였다. 열교환기를 통하여 냉각된 공기의 온도를 일정하게 유지시키면서 상온의 공기를 혼합시킨 결과 상온의 공기 유량이 증가함에 따라 혼합 공기의 온도도 거의 선형적으로 증가함을 확인하였다. 이에 따라 저온 환경 구축에 필요한 다양한 유량의 저온 공기를 생성할 수 있는 가능성을 확보하였다.

  • PDF

인삼의 온도에 대한 생리반응 II. 엽의 생리, 지온, 기온, 병환의 생육 (Physiological Response of Panax Ginseng to Tcmpcrature II. Leaf physiology, soil temperature, air temperature, growth of pathogene)

  • 박훈
    • Journal of Ginseng Research
    • /
    • 제4권1호
    • /
    • pp.104-120
    • /
    • 1980
  • The effects of temperature on transpiration, chlorophyll content, frequency and aperture of stomata, and leaf temperature of Panax ginseng were reviewed. Temperature changes of soil and air under spade roof were also reviewed. Growth responses of responses of ginseng plant at various temperature were assessed in relation to suseptibillity of ginseng plants. Reasonable management of ginseng fields was suggested based on the response of ginseng to various temperatures. Stomata frequency may be increased under high temperature during leaf$.$growing stage. Stomata aperture increased by high temperature but the increase of both frequency and aperture appears not enough for transpiration to overcome high temperature encountered during summer in most fields. Serial high temperature disorder, i.e high leaf temperature, chlorophyll loss, inhibition of photosynthesis, increased respiration and wilting might be alleviated by high humidity and abundant water supply to leaf. High air temperature which limits light transmission rate inside the shade roof, induces high soil temperature(optimum soil temperature 16∼18$^{\circ}C$) and both(especially the latter) are the principal factors to increase alternaria blight, anthracnose, early leaf fall, root rot and high missing rate of plant resulting in poor yield. High temperature disorder was lessen by abundant soil water(optimum 17∼21%) and could be decreased by lowering the content of availability of phosphorus and nitrogen in soil consequently resulting in less activity of microorganisms. Repeated plowing of fields during preparation seems to be effective for sterilization of pathogenic microoganisms by high soil temperature only on surface of soils. Low temperature damage appeared at thowing of soils and emergence stage of ginseng but reports were limited. Most limiting factor of yield appeared as physiological disorder and high pathogen activity due to high temperature during summer(about three months).

  • PDF