• Title/Summary/Keyword: high strength concrete beam

Search Result 470, Processing Time 0.023 seconds

Seismic Performance of Beam-Column Connections for Special Moment Frame Using 600 MPa Flexural Reinforcement (600 MPa 휨 철근을 사용한 특수 모멘트 골조의 보-기둥 접합부의 내진성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Choi, Won-Seok;Chung, Lan;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.591-601
    • /
    • 2011
  • An experimental study was performed to evaluate the seismic performance of beam-column connections using 600 MPa re-bars for beam flexural reinforcement. Three full scale specimens of interior beam-column connection and two specimens of exterior beam-column connection were tested under cyclic loading. The specimens were designed to satisfy the requirements of Special Moment Frame according to current design code. The structural performance of the specimens with 600 MPa re-bar were compared with that of the specimen with 400 MPa re-bars. The test results showed that bond-slip increased in the beam-column joint. However, the load-carrying capacity, deformation capacity, and energy dissipation capacity of the specimens with 600 MPa re-bar were comparable to those of the specimens with 400 MPa re-bars.

Bond Capacity of U-shaped reinforcement for bond splitting prevention in RC beams (고강도 횡 보강근을 적용한 RC보의 정량적인 부착강도 평가)

  • Yoon, Hye-Sun;Kim, Young-Sik;Yang, Wan-Su;Beak, Sung-Cheol;Kim, Kil-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.105-108
    • /
    • 2008
  • Although the research of high strength materials is in process briskly in the inside and outside of the country, in south korea, the research of high strength materials is insufficiency. Generally shear resistance of RC beam is influenced dominantly by amount of shear-reinforcing bars($p_w$) and yied strength($f_{wy}$). Therefore, I come to the conclusion that if use shear reinforced bar with shear reinforced bar, it leads to decrease of the quantity of shear reinforced bar and effects on the security of shear-restraint force of member. This study experimented with not only the mixture of high strength-reinforced bar and U-shaped reinforcement normal strength -reinforced bar devises efficient improvement, but also it incites improvement of bond capacity and carries out an experimental study for improvement of member resisting force, finally it evaluates bond capacity quantitatively on the lines of main reinforcement the restraint method.

  • PDF

Concrete Shear Strength of Light Weight Concrete Beams Reinforced with GFRP bar (GFRP bar 경량콘크리트 보의 콘크리트 전단강도)

  • Jin, Min-Ho;Jang, Hee-Suk;Kim, Chung-Ho;Baek, Dong-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.177-180
    • /
    • 2008
  • Recently, the research of FRP bar as an alternative reinforcing material in reinforced concrete structures has increased to get an innovative solution to the corrosion problem. In addition to the noncorrosive nature of FRP materials, they also have a high strength-to-weight ratio. Therefore, when light weight concrete reinforced with FRP bar is used in marine environment, for instance floating structures, some advantages can be expected. But researches for the light weight concrete structure using FRP bar as a flexural reinforcement are limited to date. In this paper, the concrete shear contribution of the light weight concrete beam reinforced with GFRP bar was studied. Experiment for beams varying concrete compressive strengths and flexural reinforcement ratios was conducted and analysed. The test results showed that 75% of values obtained from proposed equation in preceding research were well agreed with the test results and were better results than the one predicted by the ACI 440.1R-06 code.

  • PDF

Flexural Behavior of High-Strength Reinforced Concrete Beam with Recycled Aggregate Strengthened by FRP Plate (FRP로 보강된 순환골재 고강도 철근콘크리트 보의 휨거동)

  • Hong, Seong-Uk;Lee, Seung-Ho;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.126-132
    • /
    • 2018
  • As means to increase the use of concrete with recycled coarse aggregate (RCA), this study aims to evaluate the applicability for flexural strengthening of reinforced concrete beam with high-strength concretes and RCA on which FRP plates, used for repair and strengthening of old and low-durability reinforced concrete structures, is applied. In order to increase the adhesive force of epoxy and FRP plate, FRP plate was installed according to Near-Surface-Mounted (NSM) method. 12 specimens were manufactured using substitution rate of RCA (30%), concrete strengths (40MPa, 60MPa), diameters of deformed bar (D10, D13), and types of FRP plate (AFRP, CFRP) as variables to analyse flexural performance according to FRP plate and substitution rate of recycled aggregate. As a result, in all specimens, specimens strengthened by FRP plate showed a maximum of 17% increase in performance compared to specimens without FRP plate and strengthening performance of CFRP was found to be higher than AFRP. When modulus of rupture was used, the value of cracking moment was similar to that of the reference equation. As bending moment of some specimens strengthened by FRP plate failed to satisfy the criteria of KCI 2012 and ACI 440-2R, additional experiment is deemed as necessary.

Experimental study on repair of corroded steel beam using CFRP

  • Chen, Meiling;Das, Sreekanta
    • Steel and Composite Structures
    • /
    • v.9 no.2
    • /
    • pp.103-118
    • /
    • 2009
  • It has been reported that more than thirty five percent of steel bridges in the USA are structurally deficient because of structural degradations. The degraded structures need either full replacement or rehabilitation such that they are able to provide the required services for a longer period of time. The cost for repair in most cases is far less than the cost of replacement. Moreover, repair method generally takes less time than replacement and also reduces service interruption time. Modern advanced composites have been used in aerospace and automotive fields since World War II. In the recent past, because of the high strength-to-weight ratio and high stiffness-to-weight ratio, these composite materials have been introduced to civil engineering infrastructures primarily for repair and rehabilitation of concrete structures. However, only a few preliminary studies on repair of corroded steel structures using theses composite materials are reported in the literature available in the public domain. Thus, in this study, a series of laboratory tests was undertaken to evaluate the effectiveness of this repair method using carbon fiber reinforced polymer composite. The paper discusses the test method and test results obtained from these tests.

Erection Capability of Heavy Precast Frames with Metal Plates using Wet Concrete for Tolerance (톨러런스기반 플레이트 접합 장치를 사용한 고중량 RC보의 설치 성능)

  • Hong, Won-Kee;Nguyen, Van Tien;Nguyen, Manh Cuong;Nkundimana, Eric
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.12-13
    • /
    • 2021
  • Methods for the manufacture, erection, and assembly of heavy frame modules were proposed. Interferences among precast members were prevented by using bolted metal plates for dry precast beam-to-column joints during assembly with a clearance for tolerance implementing grouted concrete filler plates instead of metal filler plates. Clearances for tolerances were provided to avoid conflictions among components during erection phases. These gaps were, then, grouted by high-strength mortar. The constructability of new connections of a beam-to-column joint using bolted metal plates for precast structures was examined using a full-scale assembly test in which practical observations indicated that members could be aligned and placed accurately in both horizontal and vertical directions, leading to a fast and convenient assembling. Bolt holes of the endplate were properly aligned using couplers with 30 mm fastened length embedded in the columns. The assembly test demonstrated the erection safety and structural stability of the proposed joints that were without filler plates when they were subjected to heavy loads at the time of their erection. The facile and rapid assembly of precast beam-to-column connections with a 30 mm tolerance was observed. The proposed assembly method is rapid, sustainable, and resilient, replacing the conventional methods of concrete frame construction, offering a connection that can be used in constructing infrastructure, such as buildings and pipe-rack frames.

  • PDF

Finite element and design code assessment of reinforced concrete haunched beams

  • Gulsan, Mehmet Eren;Albegmprli, Hasan M.;Cevik, Abdulkadir
    • Structural Engineering and Mechanics
    • /
    • v.66 no.4
    • /
    • pp.423-438
    • /
    • 2018
  • This pioneer study focuses on finite element modeling and numerical modeling of three types of Reinforced Concrete Haunched Beams (RCHBs). Firstly, twenty RCHBs, consisting of three types, and four prismatic beams which had been tested experimentally were modeled via a nonlinear finite element method (NFEM) based software named as, ATENA. The modeling results were compared with experimental results including load capacity, deflection, crack pattern and mode of failure. The comparison showed a good agreement between the results and thus the model used can be effectively used for further studies of RCHB with high accuracy. Afterwards, new mechanism modes and design code equations were proposed to improve the shear design equation of ACI-318 and to predict the critical effective depth. These equations are the first comprehensive formulas in the literature involving all types of RCHBs. The statistical analysis showed the superiority of the proposed equation to their predecessors where the correlation coefficient, $R^2$ was found to be 0.89 for the proposed equation. Moreover, the new equation was validated using parametric and reliability analyses. The parametric analysis of both experimental and predicted results shows that the inclination angle and the compressive strength were the most influential parameters on the shear strength. The reliability analysis indicates that the accuracy of the new formulation is significantly higher as compared to available design equations and its reliability index is within acceptable limits.

Critical Temperature for Inter-Laminar Shear Strength and Effect of Exposure Time of FRP Rebars (FRP 보강근의 계면전단강도에 대한 임계온도와 노출시간의 영향)

  • Moon, Do-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.45-51
    • /
    • 2013
  • Short beam tests of GFRP and CFRP specimens exposed to high temperature were conducted to measure the inter-laminar shear strength. For the phase I test, the exposure time and temperature were varied to measure reduction in the strength due to the applied conditions. As a results, the critical temperature was found to $270^{\circ}C$ for the both FRP reinforcements. The high temperature, which causes 50% loss of inter-laminar shear strength, is defined as the critical temperature in this study. It should be noted that the critical temperature for the inter-laminar shear strength is mainly dependent on resin properties not on fiber type. In the phase II test, the effect of exposure time was investigated at intervals of 0.25hour for the critical temperature. All test results demonstrate that the exposure time effect is not significant compared to the maximum exposure temperature, but it is not negligible and, moreover, is significant at the critical temperature.

An Experimental Study on the Fatigue Behavior of Steel-Concrete Composite Bridge Deck (강-콘크리트 합성 교량 바닥판의 피로거동에 대한 실험적 연구)

  • 심정욱;김상효;정연주;박휘립
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.499-504
    • /
    • 2003
  • Future bridge decks must have high load-resistance capacity as well as fatigue strength to withstand the increase in traffic loading and the increase in span length between girders due to the decrease in the number of main girders. Steel-concrete composite bridge decks may be proper deck types to satisfy such requirements. To promote the application of composite bridge decks, a rational process to predict and evaluate the fatigue behavior of steel concrete composite bridge deck is required. Various types of steel-concrete composite bridge decks have been developed in many countries. In this study, combining advantages of the existing composite deck types, a new type of composite bridge deck is proposed. An experimental study is performed to examine the fatigue behavior of the proposed composite bridge deck. This composite bridge deck consists of corrugated steel sheet, welded T-beams, stud-type shear connectors and reinforced concrete filler. The fatigue tests are conducted under four-point bending test with three different stress ranges in constant amplitude. The fatigue category of the fillet welding between corrugated steel sheet and the T-beam is evaluated based on the S-N data obtained from the experiment.

  • PDF

Characteristics of Flexural Behavior of Composite Section Consisting of Steel Girder with 80MPa High Strength Concrete on Compressive Flange (압축 플랜지에 80MPa급 고강도 콘크리트가 합성된 I형 강거더의 휨거동 특성)

  • Lee, Juwon;Yang, In-Wook;Lim, Eol;Ha, Tae-Yul;Lee, Kwan-Jong
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.455-464
    • /
    • 2017
  • Static loading test was performed on a composite girder with an I-shaped steel girder and SUPER concrete on the top of the steel in order to evaluate flexural behavior characteristics. Total length of the test specimen was 25m long and the depth was 786mm including compressive concrete section('casing' hereafter) with 80MPa strength. 4-point loading on simply-supported beam was applied up to 2,010kN. Results showed that yield strength at tensile steel was 2.7 times greater than service load and the ratio of ductility was 1.481. No cracks were found on the casing surface and the relative slip between different sections was insignificant.