• 제목/요약/키워드: high screen 4k

검색결과 284건 처리시간 0.032초

Rapid Screening of Phospholipid Biomarker Candidates from Prostate Cancer Urine Samples by Multiple Reaction Monitoring of UPLC-ESI-MS/MS and Statistical Approaches

  • Lim, Sangsoo;Bang, Dae Young;Rha, Koon Ho;Moon, Myeong Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1133-1138
    • /
    • 2014
  • Ultrahigh performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI- MS/MS) provides a high-speed method to screen a large number of samples for small molecules with specific properties. In this study, UPLC-ESI-MS/MS with multiple reaction monitoring (MRM) was employed to screen urinary phospholipid (PL) content for biomarkers of prostate cancer. From lists of urinary PLs structurally identified using nanoflow LC-ESI-MS/MS, 52 PL species were selected for quantitative analysis in urine samples between 22 cancer-free urologic patients as controls and 45 prostate cancer patients. Statistical treatment of data by receiver operating characteristic (ROC) analysis yielded 14 PL species that differed significantly in relative concentrations (area under curve (AUC) > 0.8) between the two groups. Among PLs present at higher levels in prostate cancer urine, phosphatidylcholines (PCs) and phosphatidylinositols (PIs) constituted the major head group PLs (3 PCs and 7 PIs). For technical reasons, PL species of low abundance may be underrepresented in data from UPLC-ESI-MS/MS performed in MRM mode. However, the proposed method enables the rapid screening of large numbers of plasma or urine samples in the search for biomarkers of human disease.

스크린도어 설치 후 서울지하철역 라돈 농도의 변화 특성 (A Noticeable Change in Indoor Radon Levels After Platform Screen Doors Installation in Seoul Subway Station)

  • 전재식;윤종철;이호찬;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.59-67
    • /
    • 2012
  • Platform screen doors (PSD) installed at 289 stations in Seoul metropolitan subway from November 2005 to December 2009, are expected to prevent death from a fall and improve air quality. In this study, we systematically surveyed changes in radon concentrations before and after PSD installation in Seoul metropolitan subway stations. By solid-state nuclear track detectors (SSNTD), the radon concentrations before and after the PSD installation were measured at 54 stations of 6 lines from 2 to 7 reported to have relatively high radon concentrations. Mean radon concentrations at platforms were decreased by approximately 56% from 121.7 Bq/$m^3$ to 54.0 Bq/$m^3$. Before PSD installation, mean radon concentrations were in the decreasing order for subway lines 7, 5, 6, 3, 4 and 2. On the other hand, after PSD installation the order was changed to 5, 6, 7, 3, 4 and 2. According to a radon map of Seoul metropolitan subway, the number of platforms where radon concentration over was 74 Bq/$m^3$ decreased from 38 to 12 after PSD installation.

흉부(胸部) 경선질촬영(硬線質撮影)에 있어서 피폭선양(被曝線量)의 저감(低減)에 관(關)한 연구(硏究) (A Study on Image Quality and Exposure Dose of Hard-radiation Radiography of the Chest)

  • 임태랑;석전유치;전전미향;앵정달야;김정웅;황종선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권2호
    • /
    • pp.15-21
    • /
    • 1991
  • Experiment was conducted on the image quality and exposure dose following replacement of $CaWO_4$ system screen BH-III and BX-III which have so far been used for high-voltage hard-radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm+Al 1.4 mm(HVL : Al 8.8 mm), Cu 1.3 mm+Al 1.0 mm(HVL : Al 10.6 mm) and Cu 1.8 mm+Al 1.5 mm(HVL : Al 11.4 mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition(HVL : $Al\;8.8\;mm{\sim}Al\;11.4\;mm$). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was $18.9\;{\mu}Gy$ at HVL Al 8.8 mm, $17.5\;{\mu}Gy$ at Al 10.6 mm and $15.7\;{\mu}Gy$ at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of $Cu\;1.3\;mm{\sim}1.8\;mm+Al\;1.0\;mm{\sim}1.5\;mm(1/16\;VL{\sim}1/32\;VL)$ seemed to be a limit.

  • PDF

부산 지하철 소음도 조사 및 평가 (Investigation and Evaluation of Noise Level of the Busan Subway)

  • 이장명;정진국;정진석
    • 대한환경공학회지
    • /
    • 제33권4호
    • /
    • pp.243-250
    • /
    • 2011
  • 부산지하철 3개 노선에 대한 소음도 조사 및 비교 평가가 이루어 졌다. 차량이 역을 다 빠져 나간 순간부터 차량이 다음 역에 도착할 때까지를 기준으로 하여 차량 내부에서의 평균 소음값을 측정하였다. 또한 차량이 역사 도착 시 측정과 차량이 역사 출발 시 측정으로 나누어서 측정하였다. 주간시간대(오전9시~오후6시)와 야간시간대(오후6시~오후10시)로 구분하여 측정하였으나 주 야간 차이가 크지 않아 주 야간의 차이를 두지 않고 전체적으로 평균을 취했다. 2010년 5월과 7월 두 차례 부산지하철의 차량실내 소음도를 측정하여 실험에 대한 재현성을 검정하였다. 노선별 스크린 도어 효과, 도상조건, 열차차종 및 노선별 곡률반경 변화에 따른 소음도 차이가 조사되어 졌다. 부산지하철 3개 노선 중 2호선의 소음도가 가장 높았으며 이에 대한 방안도 강구 되었다. 스크린도어가 미설치된 역이 설치된 역에 비하여 소음도가 약 10 dB(A) 정도 높았으며 S 자형의 급곡선부에서 소음도가 높음이 확인되었다.

Evidence-based Screening, Early Diagnosis and Treatment Strategy of Cervical Cancer for National Policy in Low-resource countries: Example of India

  • Saxena, Upma;Sauvaget, Catherine;Sankaranarayanan, Rengaswamy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1699-1703
    • /
    • 2012
  • Cervical cancer remains the most frequent cancer in women from the developing world. More than 88% of deaths occur in low-income countries, and it is predicted to climb to 91.5% by 2030. Although Pap-based screening programmes have shown to be effective in reducing the disease burden in high-resource countries, implementation and sustention of cytology-based programmes is quite challenging in low-resource settings. The present paper reviews evidence-based alternatives of screening methods, triaging algorithm, treatment of cervical precancerous lesions, and age-group at screening appropriate for low-income countries. Evidence shows that visual inspection methods using diluted acid acetic or Lugol's iodine, and HPV-DNA testing are more sensitive tests than the Pap-smear screening test. Visual inspection allows an immediate result and, when appropriate, may be immediately followed by cryotherapy, the so called "screen-and-treat" approach, achieved in a single visit, by trained nurses and midwives. Examples of cervical cancer prevention programmes in India and selected low-income countries are given.

고온저장시험에 의한 RF SAW Filter의 고장분석 (Failure Analysis of RF SAW Filter by High Temperature Storage Test)

  • 김영구;김태홍;유종준
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.140-144
    • /
    • 2003
  • To investigate failure analysis of surface acoustic wave (SAW) filter for radio frequency, high temperature storage test was carried out. The failure criteria were insertion loss at passband and rejection level at stopband. As a result, the insertion loss at passband increase about 4 dB was due to damages of interdigital transducer (IDT). That is caused by poor adhesion between metal electrode(AI) and piezoelectric substrate and defects on a manufacturing process. This result indicates that good adhesion between electrode and ceramic substrate is important factor And also we investigated the demage factors of electrode. Screen possible of saw filter using high temperature storage test(HTOL) in the manufacturing phase be presented.

  • PDF

MF(Multi-Function) Cathode for High Current Density CRT

  • Kim, Tae-Wook;Bae, Min-Cheol;Youn, Young-Jun
    • Journal of Information Display
    • /
    • 제5권4호
    • /
    • pp.23-26
    • /
    • 2004
  • A limitation of oxide cathode is the high current density, caused by low electrical conductivity of an emitter layer. This limitation can be overcome by increasing the conductivity, and uniform dispersion of Ni powder and pore agent could be achieved by using the screen-printing method. This new cathode has shown not only high current density reliability but also improved performance characteristics and as such given the name "Multi-Function cathode". It is expected to be a good replacement of the impregnated cathode.

승화전사(昇華轉寫) 디지털 프린팅을 활용한 우산디자인 개발 - 한국적 이미지를 활용하여 - (The Design Development for Umbrella by Sublimation Transfer Digital Textile Printing - To Utilize Korean Traditional Images -)

  • 조문희
    • 한국의상디자인학회지
    • /
    • 제12권4호
    • /
    • pp.207-221
    • /
    • 2010
  • This study aim to suggest how alter the korean traditional image design for umbrellas by sublimation transfer digital textile printing. Umbrellas are highly depend on design and made from polyester fiber which is proper item to utilize sublimation transfer digital textile printing. Sublimation transfer digital textile printing system can use computer system to create the delicate high dense images and one full layout through the hole umbrella. It can create distinctive style of design compare with former screen printing umbrella design. As a result of this study, Korean traditional images were adopted and recreated for umbrellas as the modern practical item. 7 of umbrella designs were developed and sample umbrellas could be produced in short period comparing with screen printing process. Through this study, as green printing process, sublimation transfer digital textile printing will be more applied to manufacture high quality textile products along with design development, thus it is expected as an alternative plan to leads growth of umbrella industries.

  • PDF

기기 면적 대비 높은 화면 비율을 갖는 터치 패널 디스플레이 제조를 위한 차광 테이프의 개발 (Development of Shading Tape for Manufacturing of Touch Panel Display with High Screen-to-Body Ratio)

  • 김기출
    • 융합정보논문지
    • /
    • 제7권4호
    • /
    • pp.75-81
    • /
    • 2017
  • 정보기술의 디자인 트렌드는 시대에 따라 빠르게 변해왔으며, 최근의 정보 디스플레이의 디자인 트렌드는 베젤리스 디스플레이가 대세이다. 베젤리스 또는 에지리스 디스플레이는 휴대폰 디스플레이의 새로운 트렌드로 부상하고 있다. 본 논문에서는 이른바 베젤리스 디스플레이라고 불리는 기기 면적 대비 높은 화면 비율을 갖는 터치패널 디스플레이의 조립 공정에 적합한 차광 테이프를 개발하였다. 차광 테이프는 자외선 경화형 아크릴계 감압성 점착제를 PET 필름 위에 롤투롤 공정으로 코팅하여 제조하였다. 자외선 경화형 감압성 점착제는 톨루엔을 전혀 사용하지 않는 친환경적인 제조 방법으로 합성되었다. 제조된 차광 테이프의 점착력은 자동화된 인장시험기로 분석하였으며, 형상유지 특성인 칙소성은 주사 전자 현미경으로 분석하였다. 그 결과 제조된 차광 테이프는 터치패널 디스플레이의 조립 공정에 적합한 높은 점착력과 우수한 칙소성을 나타내었다. 이러한 기능성 차광 테이프의 개발은 그 동안 차광 테이프의 칙소성 부족으로 인하여 야기되었던 터치 패널 디스플레이 조립 공정의 생산성향상 및 품질안정성 향상에 기여할 것으로 기대된다.

스털링기관 재생기내의 작동유체 유속 및 마찰저항 특성(II) - 작동유체 유동마찰저항 특성 - (Velocity and Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator (II) - Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator -)

  • 김태한;조창래
    • Journal of Biosystems Engineering
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2008
  • The output of the Stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide basic data for the design of regenerator matrix, characteristics of flow friction loss were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, two different wire screens were used. The results are summarized as follows; 1. With the wire screen of No. 50 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 3 times higher than that of one directional flow, not too much influenced by the number of packed meshes. 2. With the wire screen of No. 100 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 2.5 times on the average higher than that of one directional flow, not too much influenced by the number of packed meshes. 3. Under one directional flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f=\frac{0.00326639}{Re\iota}-1.29106{\times}10^{-4}$$ 4. Under oscillating flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f_r=\frac{0.000918567}{Re\iota}+1.86101{\times}10^{-5}$$ 5. The pressure drop is shown as high in proportion as the number of meshes has been higher, and the number of packed wire screens as matrices increases.