• Title/Summary/Keyword: high screen 4k

Search Result 284, Processing Time 0.025 seconds

THE COMPARATIVE EVALUATION OF FILM-SCREEN COMBINATIONS (증감지와 필름에 따른 방사선상 변화에 대한 연구)

  • Choi Gyeong Ja;Choi Syng Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.213-225
    • /
    • 1988
  • This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, LM, LF and conventional screen OM, OH, XOR, OKa and exposed the step wedge to impulse 2, 3, 4, 6, 10, 15, 24,3 8, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films produced high speed, and the AX film was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  • PDF

High Power Characteristics of Amorphous $MnO_2$ Electrode by Variation of Electrode Thickness (비정질 $MnO_2$ 전극의 전극두께에 따른 고출력 특성 변화)

  • Seong W. K.;Kim E. S.;Lee H. Y.;Kim S. W.
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.235-240
    • /
    • 2000
  • Screen-printing and doctor blade method were investigated and proposed as an electrode coating process for high power capacitor. CV measured from the amorphous $MnO_2$ electrode prepared by screen-printing shows closer to ideal capacitor characteristics. Specific capacitances calculated from CVs with potential scan rate of 50mV/s were 5.8, 81.8, and 172.0 F/g for electrode thickness of $140{\mu}m,\;24{\mu}m,\; 3{\mu}m$, respectively. Assumed that utilization of active $MnO_2$ in electrode of screen-printing is $100\%$, those were $3.4\%$ in one of paste method and $47.6\%$ in one of doctor blade method. The screen-printing can be good technique to coat thin film on current collector for high power application.

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

Analysis of Screen Content Coding Based on HEVC

  • Ahn, Yong-Jo;Ryu, Hochan;Sim, Donggyu;Kang, Jung-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.231-236
    • /
    • 2015
  • In this paper, the technical analysis and characteristics of screen content coding (SCC) based on High efficiency video coding (HEVC) are presented. For SCC, which is increasingly used these days, HEVC SCC standardization has been proceeded. Technologies such as intra block copy (IBC), palette coding, and adaptive color transform are developed and adopted to the HEVC SCC standard. This paper examines IBC and palette coding that significantly impacts RD performance of SCC for screen content. The HEVC SCC reference model (SCM) 4.0 was used to comparatively analyze the coding performance of HEVC SCC based on the HEVC range extension (RExt) model for screen content.

Improvement of Polarization Maintenance Property of Scattering Polarizer Film for Double-Screen 3D Projection Display Screen Applications Via Surface Oxide Deposition (산화막 증착을 통한 이중스크린 3D 프로젝션 디스플레이 스크린용 산란형 편광필름의 편광유지도 개선)

  • Kim, Dae-Yeon;Seo, Jong-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2012
  • Keeping the polarization direction of the projection light unchanged is of crucial importance for high quality of images on a double-screen 3D projection display system. It has been found that the deposition of oxide layers on the surfaces of scattering polarizer film results in an improvement of polarization maintenance property of the film. The secondary image formed on the front screen by the light scattered from the rear screen decreases by 30% through the application of oxide layers on both surfaces of the screen. Since the oxide layer can also be used as an anti-reflection (AR) coating of the film, this method is very effective for the projection display applications.

Combined Influence of Screen based Sedentary Behavior and Sleep Duration on Obesity, Depression, and Suicidal ideation in Korean Adolescents (청소년의 비만도, 우울, 자살생각에 대한 스크린 기반 좌식활동과 수면시간의 수준별 결합효과)

  • Ra, Jin Suk;Cho, Yoon Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.2
    • /
    • pp.241-257
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the combined influence of screen based sedentary behavior and sleep duration on obesity, depression, and suicidal ideation in Korean Adolescents. Methods: This cross sectional study used secondary data from the 2013 Adolescent Health Behavior Online Survey. A total of 27,929 high school students were included in the study. Logistic regression was used for analysis of the combined influence of screen based sedentary behavior and sleep duration on obesity, depression, and suicidal ideation. Results: Obesity was more prevalent among adolescents who had ${\geq}$ 4h of screen based sedentary behavior and <7h of sleep duration compared to the reference group, defined as < 2h of screen time and > 7h of sleep duration. Depression and suicidal ideation were more prevalent among adolescents who had 2-4h of screen based sedentary behavior and <7h of sleep duration compared to the reference group. Conclusion: Based on the results of this study, maintaining a low (< 2h) level of screen based sedentary behavior and appropriate sleep duration over 7 hours per day is essential for prevention of adolescent obesity, depression, and suicidal ideation.

Effects of Substrate and Sintering Conditions on the Properties of Screen Printed Bi-Pb-Sr-Ca-Cu-O Superconduction Thick Films (Screen printing 방법에 의한 후막형 Bi-Pb-Sr-Ca-Cu-O 초전도체의 소결조건과 기판의 초전도성에 미치는 영향)

  • 김혜동;임호빈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.26-30
    • /
    • 1990
  • Bi$\_$0.7/Pb$\_$0.3/Sr$_1$Ca$_1$Cu$\_$1.8/Ox thick films were screen printed on magnesia(MgO), silver and yttrium stabilized zirconia (YSZ) substrates and were sintered in a boat with cover to prevent the evaporation. The high-Tc phase increase and the low-Tc phase and Ca$_2$PbO$_4$ decrease with an increase in sintering temperature from 835$^{\circ}C$ to 860$^{\circ}C$. YSZ substrate interact strongly with the oxide resulting in poor superconductor, while the Ag and MgO substrates were satisfactory to make screen printed superconductors. The Bi$\_$0.7/Pb$\_$0.3/Sr$_1$Ca$_1$Cu$\_$1.8/Ox thick films screen printed both on Ag and MgO substrates show high Tc phase of ~85% and Tc of 96K.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

The Arrangement Process Optimization of Vacuum Glazing Pillar using the Design of Experiments (실험계획법을 이용한 진공유리 Pillar의 배치공정 최적화)

  • Kim, Jae Kyung;Jeon, Euy Seik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 2012
  • In this study, the optimal process condition was induced about the pillar arrangement process of applying the screen printing method in the manufacture process of vacuum glazing panel. The high precision screen printing is technology which pushes out the paste and spreads it by using the squeegee on the stainless steel plate in which the pattern is formed. The screen printing method is much used in the flat panel display field including the LCD, PDP, FED, organic EL, and etc for forming the high precision micro-pattern. Also a number of studies of screen printing method have been conducted as the method for the cost down through the improvement of productivity. The screen printing method has many parameters. So we used Taguchi method in order to decrease test frequencies and optimize this parameters efficiently. In this study, experiments of pillar arrangement were performed by using Taguchi experimental design. We analyzed experimental results and obtained optimal conditions which are 4 m/s of squeegee speed, $40^{\circ}$ of squeegee angle and distance between metal mask and glass.

Screen Printing Electrode Formation Process for Crystalline Silicon Solar Cell (결정질 실리콘 태양전지용 스크린 프린팅 전극 공정 개발)

  • Eom, Taewoo;Lee, Sang Hyeop;Song, Chan Moon;Park, Sang Yong;Lim, Donggun
    • Current Photovoltaic Research
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • The screen printing technique is one of process to form electrode for crystalline silicon solar cell and has been studied a lot, because it has many advantages such as low price, high efficiency and mass production due to simple and fast process. The reason why electrode formation is important is for influence of series resistance and amount of incident light in crystalline silicon solar cell. In this study, electrode was formed by screen printing method with various conditions like squeegee angle, printing speed, snap off, printing pressure. After optimizing various conditions, double printing method was applied to obtain low series resistance and high aspect ratio. As a result, we obtained electrode resistance 45.31 ohm, aspect ratio 4.38, shading loss 7.549% mono-crystalline silicon solar cell with optimal double screen printing condition.