• 제목/요약/키워드: high school physics

검색결과 647건 처리시간 0.026초

Effect of Heat Treatment on Radiation Shielding Properties of Concretes

  • Singh, Vishwanath P.;Tekin, Huseyin O.;Badiger, Nagappa M.;Manici, Tubga;Altunsoy, Elif E.
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.20-28
    • /
    • 2018
  • Background: Heat energy produced in nuclear reactors and nuclear fuel cycle facilities interactions modifies the physical properties of the shielding materials containing water content. Therefore, in the present paper, effect of the heat on shielding effectiveness of the concretes is investigated for gamma and neutron. The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors. Materials and Methods: The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors of ordinary and heavy concretes were investigated using NIST data of XCOM program and Geometric Progression method. Results and Discussion: The improvement in shielding effectiveness for photon and reduction in fast neutron for ordinary concrete was observed. The change in the neutron shielding effectiveness was insignificant. Conclusion: The present investigation on interaction of gamma and neutron radiation would be very useful for assessment of shielding efficiency of the concrete used in high temperature applications such as reactors.

Linear network coding in convergecast of wireless sensor networks: friend or foe?

  • Tang, Zhenzhou;Wang, Hongyu;Hu, Qian;Ruan, Xiukai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권9호
    • /
    • pp.3056-3074
    • /
    • 2014
  • Convergecast is probably the most common communication style in wireless sensor networks (WSNs). And linear network coding (LNC) is a promising concept to improve throughput or reliability of convergecast. Most of the existing works have mainly focused on exploiting these benefits without considering its potential adverse effect. In this paper, we argue that LNC may not always benefit convergecast. This viewpoint is discussed within four basic scenarios: LNC-aided and none-LNC convergecast schemes with and without automatic repeat request (ARQ) mechanisms. The most concerned performance metrics, including packet collection rate, energy consumption, energy consumption balance and end-to-end delay, are investigated. Theoretical analyses and simulation results show that the way LNC operates, i.e., conscious overhearing and the prerequisite of successfully decoding, could naturally diminish its advantages in convergecast. And LNC-aided convergecast schemes may even be inferior to none-LNC ones when the wireless link delivery ratio is high enough. The conclusion drawn in this paper casts a new light on how to effectively apply LNC to practical WSNs.

Cyclic Shift Based Tone Reservation PAPR Reduction Scheme with Embedding Side Information for FBMC-OQAM Systems

  • Shi, Yongpeng;Xia, Yujie;Gao, Ya;Cui, Jianhua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권8호
    • /
    • pp.2879-2899
    • /
    • 2021
  • The tone reservation (TR) scheme is an attractive method to reduce peak-to-average power ratio (PAPR) in the filter bank multicarrier with offset quadrature amplitude modulation (FBMC-OQAM) systems. However, the high PAPR of FBMC signal will severely degrades system performance. To address this issue, a cyclic shift based TR (CS-TR) scheme with embedding side information (SI) is proposed to reduce the PAPR of FBMC signals. At the transmitter, four candidate signals are first generated based on cyclic shift of the output of inverse discrete Fourier transform (IDFT), and the SI of the selected signal with minimum peak power among the four candidate signals is embedded in sparse symbols with quadrature phase-shift keying constellation. Then, the TR weighted by optimal scaling factor is employed to further reduce PAPR of the selected signal. At the receiver, a reliable SI detector is presented by determining the phase rotation of SI embedding symbols, and the transmitted data blocks can be correctly demodulated according to the detected SI. Simulation results show that the proposed scheme significantly outperforms the existing TR schemes in both PAPR reduction and bit error rate (BER) performances. In addition, the proposed scheme with detected SI can achieve the same BER performance compared to the one with perfect SI.

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

Global Mapping of Saturnian Haze

  • Park, Jaekyun;Kim, Sang Joon;Melin, Henrik;Stallard, Tom S.
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.82.1-82.1
    • /
    • 2019
  • Recent analyses of spectro-images of Saturn observed by Visual and Infrared Mapping Spectrometer (VIMS)/Cassini revealed altitudinal distributions of the spectral structure of haze in Saturn's south-polar regions (Kim et al., 2018) and at $55^{\circ}N$ latitude (Kim et al., 2012). However, other regions of Saturn still have not been investigated. We derived series of high-spatial resolution VIMS images of Saturn's limb at various latitudes. Using our developed code, the altitudinal intensity profiles of $3.3-{\mu}m$ emission and H3+ through different latitudes were plotted. Then we obtained the averaged vertical spectra of $3.3-{\mu}m$ emission which is all blended with fluorescent methane and hydrocarbon haze. The vertically-resolved spectra were measured from the limb of Saturn in 50km intervals to see altitudinal variance. We will present a comparison of spectral structures of $3.3-{\mu}m$ emission with different latitudes. Further investigation using radiative transfer to extract adjacent fluorescent CH4, C2H6, and H3+ is needed to derive spectral structure of pure haze. We look forward to a better understanding of aging process in a global view.

  • PDF

Structure of an Oncology Information System Based on a Cost-Effective Relational Database for Small Departments of Radiation Oncology

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.172-178
    • /
    • 2020
  • Purpose: Radiation oncology information systems (ROIS) have evolved toward connecting and integrating information between radiation treatment procedures. ROIS can play an important role in utilizing modern radiotherapy techniques that have high complexity and require a large amount of information. Methods: Using AccessTM software, we have developed a relational database that is highly optimized for a radiotherapeutic workflow. Results: The prescription table was chosen as the core table to which the other tables were connected, and three types of forms-charts, worklists, and calendars- were suggested. A fast and reliable channel for delivering orders and remarks according to changes in the situation was also designed. Conclusions: We expect our ROIS design to inspire those who need to develop and manage an individual ROIS suitable for their radiation oncology departments at a low cost.

Gamma-Ray and Neutrino Emissions from Starburst Galaxies

  • Ha, Ji-Hoon;Ryu, Dongsu;Kang, Hyesung
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.37.1-37.1
    • /
    • 2020
  • Cosmic-ray protons (CRp) are efficiently produced at starburst galaxies (SBGs), where the star formation rate (SFR) rate is high. In this talk, we present estimates of gamma-ray and neutrino emissions from nearby SBGs, M82, NGC253, and Arp220. Inside the starburst nucleus (SBN), CRp are accelerated at supernova remnant (SNR) shocks as well as at stellar wind (SW) termination shocks, and their transport is governed by the advection due to starburst-driven wind and diffusion mediated by turbulence. We here model the momentum distributions of SNR and SW-produced CRp with single or a double power-law forms. We also employ two different diffusion models, where CRp are resonantly scattered off large-scale turbulence in SBN or self-excited waves driven by CR streaming instability. We then calculate gamma-ray/neutrino fluxes. The observed gamma-ray fluxes by Fermi-LAT, Veritas, and H.E.S.S are well reproduced with double power-law distribution for SNR-produced CRp and the CRp diffusion by self-excited turbulence. The estimated neutrino fluxes are <~10-3 of the atmospheric neutrino flux in the energy range of Eneutrino <~100 GeV and <~10-1 of the IceCube point source sensitivity in the energy range of Eneutrino >~60 TeV.

  • PDF

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

Near-Infrared Spectra of Super Star Clusters in M82

  • ;;임명신
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.61.2-61.2
    • /
    • 2012
  • We observed selected super cluster regions in M82 with 5'5 arcsec field-of-view using near-IR high resolution echelle spectrometer, IRCS, at the SUBARU 8.2 m telescope. The slit width of 0.15 arcsec makes the high resolution (R ${\approx}$ 20,000) spectra in the H and K bands. In this poster, we present sample spectra of [FeII] lines and ro-vibration lines of $H_2$ which trace ionic shocks in the intercloud regions and molecular shocks. The line widths of $Br{\gamma}$ line are also measured to derive the velocity dispersion within the super star clusters.

  • PDF

How Does Cognitive Conflict Affect Conceptual Change Process in High School Physics Classrooms?

  • Lee, Gyoung-Ho;Kwon, Jae-Sool
    • 한국과학교육학회지
    • /
    • 제24권1호
    • /
    • pp.1-16
    • /
    • 2004
  • The purpose of this study was to examine the role of cognitive conflict in the conceptual change process. Ninety-seven high school students in Korea participated in this study. Before instruction, we conducted pretests to measure learning motivation and learning strategies. During instruction, we tested the students' preconceptions about Newton's 3rd Law and presented demonstrations. After this, we tested the students' cognitive conflict levels and provided students learning sessions in which we explained the results of the demonstrations. After these learning sessions, we tested the students' state learning motivation and state learning strategy. Posttests and delayed posttests were conducted with individual interviews. The result shows that cognitive conflict has direct/indirect effects on the conceptual change process. However, the effects of cognitive conflict are mediated by other variables in class, such as state learning motivation and state learning strategy. In addition, we found that there was an optimal level of cognitive conflict in the conceptual change process. We discuss the complex role of cognitive conflict in conceptual change, and the educational implications of these findings.