• Title/Summary/Keyword: high safety

Search Result 10,654, Processing Time 0.042 seconds

A research on the actual condition fire dangerousness for electric installation of stables (축사 전기설비 화재위험성 실태조사)

  • Lee, Young-Soo;Kim, Myeong-Soo;Kim, Man-Keon;Kim, Hyeog-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.65-77
    • /
    • 2006
  • There is not high level to fire number in stables, but if it were fire, there would be happened many property damage in a national or personal. We grasp safety awareness of a safety supervisor enforcing question survey of electric installation for national stables, and investigate use the actual condition of electric installment with a heating apparatus, a ventilating system, a distributing board, a wiring apparatus etc high fire dangerousness among electric installment using a stables I hope to make use of data to protect a electric fire submitted thesis.

  • PDF

The Estimation of Fatigue Life for Al/CFRP Hybrid Laminated Composites using the Strain-Life Method (변형률-수명 평가기법을 이용한 Al/CFRP 하이브리드 적층 복합재의 피로수명 측정)

  • Yang, Seong Jin;Kwon, Oh Heon;Jeon, Sang Koo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.7-14
    • /
    • 2021
  • Hybrid laminated Al/carbon-fiber-reinforced plastic (CFRP) composites are attracting considerable attention from industries such as aerospace and automobiles owing to their excellent specific strength and specific rigidity. However, when this material is used to fabricate high-pressure fuel storage containers subjected to repeated fatigue loads, fatigue life evaluation for the working load is regulated as an important criterion for operational safety and ease of maintenance. Among the existing evaluation methods for these vessels, the burst test and the hydraulic repeat test require expensive facilities. Thus, the present study aims to develop an improved fatigue life test for Al/CFRP laminated hybrid composites. The test specimen was manufactured using a curved mold considering the shape of a type III high-pressure storage container. The strain-life method was used for fatigue life evaluation, and the life was predicted based on the transition life. The results indicate that the more complex the CFRP stacking sequence, the longer is the transition life. This test method is expected to be useful for ensuring the fatigue safety and economy of hybrid laminate composites.

The Effects of Personality and Attitude on Risky Driving Behavior Among Public van Drivers: Hierarchical Modeling

  • Tanglai, Wirampa;Chen, Ching-Fu;Rattanapan, Cheerawit;Laosee, Orapin
    • Safety and Health at Work
    • /
    • v.13 no.2
    • /
    • pp.187-191
    • /
    • 2022
  • Background: Traffic injuries have become a significant public health problem in low- and middle-income countries. Several studies have examined the role of personality and attitude toward traffic safety in predicting driving behaviors in diverse types of drivers. Few studies have investigated risky behavior among public passenger van drivers. This study aims to identify the predictors of self-reported risky driving behavior among public van drivers. Method: A total of 410 public van drivers were interviewed at terminal stations in Bangkok. Hierarchical regression models were applied to determine the effects of demographics, personality traits, and attitude on self-reported risky driving behaviors. Results: The results indicated that drivers with a high education level, more working days, and high scores for normlessness and anger were more likely to report risky driving behaviors (p < 0.05). Conclusion: The personality traits and attitude toward speeding account for aberrant self-reported risky driving behavior in passenger van drivers. This could be another empirical basis for evidence-based road safety interventions in the context of public transport.

Effects of Temperature and Humidity on Fungal Occurrence in Dried Red Pepper during Storage

  • Kim, Sosoo;Baek, Seul Gi;Hung, Nguyen Bao;Kim, Se-Ri;Jang, Ja Yeong;Kim, Jeomsoon;Lee, Theresa
    • Research in Plant Disease
    • /
    • v.27 no.4
    • /
    • pp.155-163
    • /
    • 2021
  • Dried red peppers are frequently contaminated with mycotoxins during storage. To determine the effect of storage environments on fungal occurrence and subsequent mycotoxin accumulation in dried red peppers, we monitored red pepper powder and whole fruit samples for fungal occurrence under various temperatures and relative humidity (RH) conditions during 340 days. Fungal occurrences fluctuated in both pepper forms throughout the storage but they were higher in pepper powder than whole one, higher under low temperatures (-20℃, 0℃, or 4℃) than others (10℃, 25℃, or 30℃), and higher under RH 93% than RH 51% and 69% in both peppers. The samples exhibiting high fungal occurrences were associated mainly with dominant species such as Aspergillussydowii, Penicillium solitum, P. roqueforti, P. polonicum, or P. chrysogenum. Mycotoxigenic species, including A. flavus, A. ochraceus, A. westerdijkiae, A. tubingensis, and P. citrinum, were also detected throughout the samples. Although mycotoxins were not detected in the samples, mycotoxigenic potential of A. flavus, A. ochraceus, and A. westerdijkiae isolates were confirmed. These results show that low temperatures (-20℃, 0℃, or 4℃) and/or high surrounding RH (>93%) are not safe environments for storage of dried red peppers as fungal growth can occur under these conditions.

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

Crossover Temperature and Ignition Delay Time of Diluted Hydrogen-Air Mixtures (희석된 수소-공기 혼합기의 크로스오버 온도와 점화지연시간)

  • Dong Youl, Lee;Eui Ju, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.18-24
    • /
    • 2022
  • Hydrogen is a clean fuel and is used in many applications in power systems such as fuel cells. It has unique properties such as wide flammability, high burning velocity, and difficulty to liquefy, which lead to critical safety issues. Fire and explosion are the most frequently occurring accidents and one of the major reasons is autoignition. In the ignition process, the chemistry of hydrogen combustion depends mainly on radical pools, and the temperature at which chain-branching and terminating rates are equal is called the crossover temperature. This study addresses the homogeneous autoignition of diluted hydrogen-air mixtures to investigate the effects of dilution on the crossover temperature to prevent explosions in the future. The new criterion for crossover temperature is introduced by only hydrogen radicals to adjust more simply. The detailed calculations indicate that the crossover temperatures are low at high dilutions of carbon dioxide and nitrogen because the concentrations of active radicals are reduced when an inert gas is added. This result is expected to contribute to hydrogen safety and realize a hydrogen society in the future.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

A Case Study on the Evaluation Technique of Evacuation Safety in Building Fire (건축물화재시의 피난안전에 관한 평가기술에 대한 사례조사)

  • Kwon, Young-Jin;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.115-116
    • /
    • 2020
  • Recently, due to fires in high-rise residential and commercial buildings and apartments in Ulsan and Busan, the issue of evacuation safety in the event of a building fire is being closely watched. In the evacuation safety design for these building fires, it is important to secure evacuation routes considering the spatial characteristics of the building or the characteristics of the occupants and to take measures to protect the evacuation routes in order to ensure the safety of the occupants in the event of a fire. Although simulation is mainly used in Korea to assess the safety of evacuation, there is a big difference in that the Building Standards Act provides tools that can be calculated more than simulation in neighboring Japan. In addition to the evaluation method, which is called the "Building Law Assessment Methods" in Japan, the research team considered that it is important to know the process of evaluation in future domestic research, and investigated the contents of the evaluation process and wanted to apply it first to domestic buildings in the future.

  • PDF

Development of Electric Vehicle Crash Scenarios and Safety Testing Methods Considering Road Infrastructure (도로 인프라를 고려한 전기자동차 충돌안전 시험법 개발)

  • Seung-Jun Hong;Jong-Wook, Lee;Gyu-Hyun, Kim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.16 no.2
    • /
    • pp.27-33
    • /
    • 2024
  • In this study, an analysis was conducted on internal and external factors related to fires in electric vehicles in order to improve the safety of electric vehicles against fire accidents. To conduct the analysis, field survey data conducted on actual electric vehicle fire accidents were used, and accident-related statistical data was used. Among them, as a result of analyzing the internal factors related to fire accidents in electric vehicles, it was confirmed that high-voltage batteries are an important factor in fire accidents caused by internal factors of electric vehicles. An analysis of external factors for fire accidents of electric vehicles was also conducted in this study. The largest number of electric vehicle accidents that occurred on public roads were mainly caused by physical external forces such as collisions. Therefore, strengthening the safety of this road infrastructure could be an additional solution to improve the fire safety of electric vehicles. As a result, based on car accident cases, two crash scenarios based on road infrastructure were derived, each of which simulates a high-speed frontal collision situation and a lower-end collision situation. Additionally, detailed test methods for these scenarios were developed.

A Study on the Automotive Structural Change of High Intensity Discharge Head lamp (자동차 전조등 고압 방전 램프 구조 변경에 대한 연구)

  • Lim, Ju-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.53-60
    • /
    • 2008
  • A test was conducted using two high density discharge lamps, the H2D and the structurally new H4D. They were tested for luminous illumination and luminous temperature in the day and night time. The test was conducted without crippling the performance of the H2D by adding a magnetic actuator, enabling it to move left to right, and up and down. By making these modifications we constructed a sample of the H4D. We compared the H2D and the H4D sample's luminous illumination and luminous temperature by using a photometer and a digital thermometer in the day and night time. We discovered that the H2D and H4D performed similarly from the data we gathered. Now we know the H4D has potential use and extensive research needs to be made to gather more detailed data.