• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.028 seconds

Assessment of 3-Dimensional Sunshine Environment Using Geographical Information System Data around Pukyong National University (부경대학교 주변 지역의 지리정보시스템 자료를 이용한 3차원 일조 환경 평가)

  • Kim, Eun-Ryoung;Park, Soo-Jin;Kim, Jae-Jin;Nam, Kyung-Yeub
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.3
    • /
    • pp.116-131
    • /
    • 2014
  • In this study, sunshine environment in an urban area is analyzed using a numerical model which considers sunshine-duration blocking by topography and buildings. The numerical model used in this study has an improvement in the algorithm detecting sunshine duration in the model domain. The main improvement in the algorithm is to detect sunshine duration using all the surfaces of any grid cell(the previous model uses the center of any grid cell). The improvement in the algorithm gives more accurate evaluation of sunshine duration at corner surfaces of buildings. Using the improvement model and geographic information system(GIS) data, sunshine environment is analysed at an building-congested area in Busan for a week in four seasons. The results show that sunshine duration can be much changed by apartment complexes, high-rise buildings, topography in the model domain.

Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.

Analytical Correction Method Based on a Comparison of the Column Shortening Measurement-Prediction in Tall Buildings (고층 건축물의 기둥축소량 계측-예측의 비교를 통한 해석보정 방안)

  • Song, Eun-Seok;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.391-399
    • /
    • 2019
  • In this study, an analytical method was proposed to correct the analysis results and minimize the errors between column shortening predictions and real values in high-rise buildings. In this regard, the construction sequence analysis of 41-story reinforced concrete buildings was performed and the results were compared to four assumed field measurements that were divided into the column and the core. The analysis correction was applied at a stage over the error limit in the column and at all stages in the core. Since the error occurred continuously after the analysis was corrected, additional corrections of the analysis resulted in a smaller error. By applying the proposed analytical correction method, it was confirmed that the long-term shortening value can be accurately predicted.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.

A preliminary numerical analysis study on the seismic stability of a building and underground structure by using SSI (SSI를 이용한 건물과 인접지하구조물의 내진 안정성에 대한 기초 수치해석 연구)

  • You, Kwang-Ho;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.23-38
    • /
    • 2018
  • Up to now, most of studies on seismic analysis have been limited to analyze buildings and underground structures individually so that the interaction between them could not be analyzed effectively. Thus, in this study, a dynamic analysis was conducted for soil-structure interaction with a complex underground facility composed of a building and an adjacent underground structure constructed on a surface soil and the bed rock ground conditions. Seismic stability was analyzed based on interstory drift ratio and bending stress of structure members. As a result, an underground structure has more effect on a high-rise building than a low-rise building. However the above structures were proved to be favorable for seismic stability. On the other hand, tensile bending stresses exceeded the allowable value at the underground part of the building and the adjacent underground structure so that it turned out that the underground part could be weaker than the above part. Therefore, it is inferred that above and underground structures should be analyzed simultaneously for better prediction of their interaction behavior during seismic analyses because there exist various structures around buildings in big cities.

Design Strength of Non-symmetric Composite Column for Modular Unit Frames (모듈러 유닛 골조용 비대칭 합성기둥의 설계강도)

  • Park, Keum-Sung;Lee, Sang-Sup;Moon, Ji-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.101-109
    • /
    • 2018
  • Modular structural systems have been used increasingly for low- and mid-rise structures such as school and apartment buildings. Studies have recently been conducted on the application of the modular structural system to high-rise buildings. To provide sufficient resistances and economical construction for the high-rise modular structural system, a composite unit modular structure was proposed. In this study, the strength of the non-symmetric composite column for the proposed composite unit modular structure was investigated through a series of tests. The experimental study focused on the effect of the slenderness of the column, eccentricity, and through bars on the strength of such a column. Design equations for the non-symmetric column for a modular unit structure were also proposed. From the results, it was found that the proposed design equations provide reasonable strength prediction of the non-symmetric composite column for the modular unit structure.

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.

Wind-Induced Motion of Tall Buildings: Designing for Occupant Comfort

  • Burton, M.D.;Kwok, K.C.S.;Abdelrazaq, A.
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • A team of researchers and practitioners were recently assembled to prepare a monograph on "Wind-Induced Motion of Tall Buildings: Designing for Habitability". This monograph presents a state-of-the-art report of occupant response to wind-induced building motion and acceptability criteria for wind-excited tall buildings. It provides background information on a range of pertinent subjects, including: ${\bullet}$ Physiological, psychological and behavioural traits of occupant response to wind-induced building motion; ${\bullet}$ A summary of investigations and findings of human response to real and simulated building motions based on field studies and motion simulator experiments; ${\bullet}$ A review of serviceability criteria to assess the acceptability of wind-induced building motion adopted by international and country-based standards organizations; ${\bullet}$ General acceptance guidelines of occupant response to wind-induced building motion based on peak acceleration thresholds; and ${\bullet}$ Mitigation strategies to reduce wind-induced building motion through structural optimization, aerodynamic treatment and vibration dissipation/absorption. This monograph is to be published by the American Society of Civil Engineers (ASCE) and equips building owners and tall building design professionals with a better understanding of the complex nature of occupant response to and acceptability of wind-induced building motion. This paper is a brief summary of the works reported in the monograph.

A Team-based Firefighter Training Simulator for Complex Buildings (대형 복합건물을 대상으로 하는 소방관 팀 훈련용 시뮬레이터 개발)

  • Lee, Jai-Kyung;Cha, Moo-Hyun;Choi, Byung-Il;Kim, Tae-Sung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.370-379
    • /
    • 2011
  • The increasing complexity of complex buildings, such as high-rise buildings and underground subway stations, presents new challenges to firefighters. In a fire in complex buildings, the importance of the collaboration between firefighters is clear. The increased demand on firefighter training for such environment is now evident. Due to cost, time, and safety issues, it is impossible to experience a real fire in such environments for training. In addition, the use of real fire for training does not enable repeatable training and the evaluation of the training is difficult. We developed a team-based firefighter training simulator for complex buildings using the virtual reality technology. It provides the training and evaluation of firefighting and mission-based team training. To model real fire phenomena in virtual space, a numerical analysis method based on fire dynamics is used. To achieve an immersive virtual environment, an augmented reality technique for the compensation of real world image and a haptic technique for heat experience are adopted. The developed training simulator can help the firefighter to respond to large and complex firefighting scenarios, while maintaining the safety of the trainees.

A Study on the Variation of Solar Access Right of Apartment Buildings According to Site Planning (공동주택 배치 계획에 따른단지내 일조 환경 변화에 관한 연구)

  • Seong, Yoon-Bok;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.35-44
    • /
    • 2004
  • In Korea, the apartment buildings have been constructed recently in large quantities to provide housing due to the gravitation of population towards large cities. However, because of this trend toward high-rise apartment, a number of problems are occurred such as the deterioration of comfort in the dwelling environment and the lack of solar access right in apartment buildings. In the building law, the sunshine hour and the minimal separated distance between apartment buildings as regulated as the criteria for the site planning. Most of site planners, however, designed the apartment site only following minimum separated distance. As a result, the problem of sunshine hours lack is caused and legal dispute concerning solar access right is also arisen. The purpose of this study is to improve solar access right regulation and to help site design of apartment planning. Accordingly, we execute empirical analysis based on computer simulation in order to find suitable separated distance between typically designed apartment buildings. First, we estimated sunshine hours according to independent building orientation, height, and length. Second, we calculated sunshine hours in various case of apartment arrangement; parallel type, courtyard type, tower type and etc. with various separated distance.