Seismic force evaluation of RC shear wall buildings as per international codes

  • Jayalekshmi, B.R.;Chinmayi, H.K.
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.191-209
    • /
    • 2016
  • Seismic codes are the best available guidance on how structures should be designed and constructed to ensure adequate resistance to seismic forces during earthquakes. Seismic provisions of Indian standard code, International building code and European code are applied for buildings with ordinary moment resisting frames and reinforced shear walls at various locations considering the effect of site soil conditions. The study investigates the differences in spectral acceleration coefficient ($S_a/g$), base shear and storey shear obtained following the seismic provisions in different codes in the analysis of these buildings. Study shows that the provision of shear walls at core in low rise buildings and at all the four corners in high rise buildings gives the least value of base shear.

Design of High Strength Concrete Filled Tubular Columns For Tall Buildings

  • Liew, J.Y. Richard;Xiong, M.X.;Xiong, D.X.
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.215-221
    • /
    • 2014
  • Ultra-high strength concrete and high tensile steel are becoming very attractive materials for high-rise buildings because of the need to reduce member size and structural self-weight. However, limited test data and design guidelines are available to support the applications of high strength materials for building constructions. This paper presents significant findings from comprehensive experimental investigations on the behaviour of tubular columns in-filled with ultra-high strength concrete at ambient and elevated temperatures. A series of tests was conducted to investigate the basic mechanical properties of the high strength materials, and structural behaviour of stub columns under concentric compression, beams under moment and slender beam-columns under concentric and eccentric compression. High tensile steel with yield strength up to 780 MPa and ultra-high strength concrete with compressive cylinder strength up to 180 MPa were used to construct the test specimens. The test results were compared with the predictions using a modified Eurocode 4 approach. In addition, more than 2000 test data samples collected from literature on concrete filled steel tubes with normal and high strength materials were also analysed to formulate the design guide for implementation in practice.

Future of Super Tall Building in Korea (우리나라 초고층 건축물의 미래)

  • Yoo, Byoung-Eok
    • Journal of the Korean Professional Engineers Association
    • /
    • v.38 no.1
    • /
    • pp.52-54
    • /
    • 2005
  • Korean metropolises are choked by lack of green space to attain the limit of horizontal expansion. The alternative plan is trying total expansion that the green zone and road are made from the rest site by high-rise buildings. And high-rise building can solve indiscriminate development to attain the limit situation. The building of landmark can be the image of the nation and the pride of the citizen. The relaxing the height restriction of government can be whole nation's interests. Appearing high-rise building in overpopulated city is the subject of a generation and this trend cannot be avoided.

  • PDF

The Program of progress control and quality control for the high-rise compound building (초고층 주상복합건물의 수장공사 공정관리 및 품질관리 방안)

  • Jung, Eul-Kyu;Lim, Chil-Soon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.111-117
    • /
    • 2003
  • Recently SAMWOO EMC received order and built interior walls which was used the day process in several high-rise compound buildings. On the way to build, this process was brought about several matter according to the progress and qualify control. So, this study is the improving way of the dry process from experiences on those constructions

A Study on the Overseas Case Analysis of Evacuation Guidance System for High-rise and Underground Complexes (초고층 및 지하연계 복합건축물 피난유도 시스템의 국외 사례 분석 연구)

  • Choi, Byeong-Yun;Kim, Dong-Oh;Seo, Jeong-Wan;Kang, Boo-Seong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.117-118
    • /
    • 2023
  • This study is a basic research study to establish an effective evacuation guidance system in case of fire in high-rise and underground-linked complex buildings. As a result of the analysis of overseas cases, it is judged that it is necessary to develop an evacuation guidance system using artificial intelligence.

  • PDF

Earthquake Response Analysis of Ordinary Moment Resisting Steel Frames (일반 모멘트 저항 철골조의 지진 응답 해석)

  • Yoon, Myung-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.4 no.1
    • /
    • pp.36-45
    • /
    • 2004
  • Allowable stress design method have been most widely used in steel structure in Korea. Recently, not only high-rise buildings but also medium or low-rise buildings were designed as steel structure. Most of low-rise steel buildings are designed as ordinary moment resisting frames(MRF). But MRFs don't have any lateral force resisting devices such as bracing in braced frames. This study focuses mainly on nonlinear seismic response analyses of small scale steel frames which will be used later as specimens for the evaluation of MRF's seismic performances. The main parameters of analyses are arrangement of column axis, $P-{\Delta}$ effect, acceleration factor etc. The object of this paper is to estimate the seismic performances of MRFs, which are mostly designed in Korea, through the results of response analyses.

  • PDF

A Study on the Decompression Performance by the Orifice Diameter (오리피스의 직경에 따른 감압성능에 관한 연구)

  • Park, Bong-Rae;Yun, Ki-Jo;Jang, Kyeong-Nam;Choi, Jung-Ung;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.57-63
    • /
    • 2012
  • The modern trend for high-rise buildings makes the application of fire protection systems difficult and the current systems have a limitation to provide appropriate functions. Indoor hydrant systems are fire suppression systems installed in most buildings that require valves, hoses, and nozzles to be manually operated in the event of a fire. Therefore, high discharge pressure can cause difficulty in the operation of indoor fire hydrant systems and damage to hoses due to a high reaction force. To prevent these problems, the pressure is reduced and decompression valves are commonly installed at angle valves which are the discharge points of indoor hydrants. In the case of high-rise buildings, however, there are cases where stable operation is difficult even with the installation of decompression valves. To verify this, we have measured the decompression performance by the orifice diameter and calculated the reaction force. Results of the study showed that decompression valves need to be produced in different sizes to provide stable decompression where high pressure is required as in high-rise buildings.

Study of a Three-Dimensional and Multi-Functional Urban High-Rise Complex in the High-Density Environment: Design Practice of Yiwu World Trade Center

  • Li, Linxue;Hou, Miaomiao;Zhang, Qi
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.1
    • /
    • pp.37-47
    • /
    • 2019
  • Facing the challenges of urban form and space quality in a high-density environment, the paper puts forward the development trend of three-dimensional and multi-functional design for an urban high-rise complex, and analyzes the design methods of establishing an urban landmark, including multi-functional composition, three-dimensional space integration, three-dimensional traffic organization and energy flow programming. Meanwhile, combined with the specific design case of Yiwu World Trade Center, the practical experience of designing a high-rise complex in China's medium-sized cities is analyzed.

Seismic design and elastic-plastic analysis of the hengda group super high-rise office buildings

  • Zhang, Xiaomeng;Ren, Qingying;Liu, Wenting;Yang, Songlin;Zhou, Yilun
    • Earthquakes and Structures
    • /
    • v.19 no.3
    • /
    • pp.175-188
    • /
    • 2020
  • The Hengda Group super high-rise building in Jinan City uses the frame-core tube structural system. With a height of 238.3 m, it is above the B-level height limit of 150 m for buildings within 7-magnitude seismic fortification zones. Therefore, it is necessary to apply performance-based seismic design to this super high-rise building. In this study, response spectrum analysis and comparative analysis of the structure are conducted using two software applications. Moreover, elastic time-history analysis, seismic analysis under an intermediate earthquake, and elastic-plastic time-history analysis under rare earthquakes are performed. Based on the analysis results, corresponding strengthening measures are implemented at weaker structural locations, such as corners, wall ends connected to framed girders, and coupling beams connected to framed girders. The failure mode and failure zone of major stress components of the structure under rare earthquakes are analysed. The conclusions to this research demonstrate that weaker locations and important parts of the structure satisfy the requirements for elastic-plastic deformation in the event of rare earthquakes.

TORANOMON HILLS - Super High-Rise Building on Urban Highway -

  • Hitomi, Yasuyoshi;Takahashi, Hiroshi;Karasaki, Hidenori
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • TORANOMON HILLS is the main building of a large-scale re-development project located in the center of Tokyo. This high-rise building has a height of 247 m and 52 floors above ground, 5 floors below ground, and $62m{\times}80m$ in plan. It is used as hotel, residential facilities, offices, shops and conference facilities. The super structure is mainly a rigid steel frame with response-control devices, using concrete-filled steel tube columns. The underground section is a mixed structure composed of steel, steel-reinforced concrete and reinforced concrete framings. The piled-raft foundation type is used. The remarkable feature of this high-rise building is that the motorway runs through the basements of the building, which makes it stand just above the motorway. This condition is an important factor of the building design. The plan shape is designed to fit along the curve of the motorway. Special columns at the corners are required to avoid placing columns in the motorway. This special column is a single inclined column in the lower floors that branches into two columns in the mid-floors to suit the column location in the upper floors. The cast steel joint is used for the branching point of each special column to securely transfer the stress.