• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.024 seconds

Wind engineering for high-rise buildings: A review

  • Zhu, Haitao;Yang, Bin;Zhang, Qilin;Pan, Licheng;Sun, Siyuan
    • Wind and Structures
    • /
    • v.32 no.3
    • /
    • pp.249-265
    • /
    • 2021
  • As high-rise buildings become more and more slender and flexible, the wind effect has become a major concern to modern buildings. At present, wind engineering for high-rise buildings mainly focuses on the following four issues: wind excitation and response, aerodynamic damping, aerodynamic modifications and proximity effect. Taking these four issues of concern in high-rise buildings as the mainline, this paper summarizes the development history and current research progress of wind engineering for high-rise buildings. Some critical previous work and remarks are listed at the end of each chapter. From the future perspective, the CFD is still the most promising technique for structural wind engineering. The wind load inversion and the introduction of machine learning are two research directions worth exploring.

Predicting the lateral displacement of tall buildings using an LSTM-based deep learning approach

  • Bubryur Kim;K.R. Sri Preethaa;Zengshun Chen;Yuvaraj Natarajan;Gitanjali Wadhwa;Hong Min Lee
    • Wind and Structures
    • /
    • v.36 no.6
    • /
    • pp.379-392
    • /
    • 2023
  • Structural health monitoring is used to ensure the well-being of civil structures by detecting damage and estimating deterioration. Wind flow applies external loads to high-rise buildings, with the horizontal force component of the wind causing structural displacements in high-rise buildings. This study proposes a deep learning-based predictive model for measuring lateral displacement response in high-rise buildings. The proposed long short-term memory model functions as a sequence generator to generate displacements on building floors depending on the displacement statistics collected on the top floor. The model was trained with wind-induced displacement data for the top floor of a high-rise building as input. The outcomes demonstrate that the model can forecast wind-induced displacement on the remaining floors of a building. Further, displacement was predicted for each floor of the high-rise buildings at wind flow angles of 0° and 45°. The proposed model accurately predicted a high-rise building model's story drift and lateral displacement. The outcomes of this proposed work are anticipated to serve as a guide for assessing the overall lateral displacement of high-rise buildings.

Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper

  • Aly, Aly Mousaad
    • Smart Structures and Systems
    • /
    • v.13 no.3
    • /
    • pp.473-500
    • /
    • 2014
  • Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.

A Study on the Regional Aesthetics of Asian High-rise Buildings

  • Kwon, Jongwook
    • Architectural research
    • /
    • v.17 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • For more than 100 years, American skyscrapers got along with the change of Modern architecture. However, high-rise building can not be regarded anymore as a monopoly of America. The purpose of this study is to clarify the aesthetic characteristics of Asian high-rise buildings. Basic concepts on the aesthetic and artistic expression of high-rise building have been discussed, emphasizing the importance of artistic characteristic. A brief introduction on the rise of Asian high-rise buildings also summarized in terms of changing trends for decades from 1970s. Among the 75 buildings in Asian countries out of 100 tallest buildings in the world, 10 buildings are selected to clarify the artistic characteristics which can be presented as an Asian trend in 21st century. The results can be summarized as follows; It was from 1990s that the Asian high-rise buildings began to express a specific regional aesthetics as a trend of post-modernism. Conventional ideas, traditional objects, and regional shapes and patterns are good instruments to successfully represent their national prides. Religions in Chinese and Islamic culture are popular motifs in Asian countries as well as feng shui and conventional idea of five primary elements. Traditional objects like pagoda and minaret are good precedents that can provide friendly recognized vertical objects. Many other interesting cases can be found referring to the traditional shapes and patterns like Chinese character, geometric pattern, Islamic sign, etc.

A Study on the general direction of Fire-Fighting Safety management in high-rise buildings (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

Development and Practice of Performance-Based Seismic Design of High-Rise Buildings in China

  • Xiao Congzhen;Li Jianhui;Li Yinbin;Qiao Baojuan;Sun Chao;Wei Yue;Ding Jiannan
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.209-214
    • /
    • 2023
  • Seismic performance-based design methods are widely used in the field of engineering. This paper introduces the current status of seismic performance-based design methods for high-rise buildings in China, and summarizes latest advancements in seismic performance-based design methods for high-rise buildings in China, with a focus on the design methods based on predetermined yield mode and the design methods based on member ductility requirements. Finally, the development direction of seismic performance-based design method for high-rise buildings is prospected.

Strategy of Fire Precaution for High Rise Buildings (긴급제언: 고층건물의 화재예방대책)

  • Hwang, Hyun-Soo
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.6
    • /
    • pp.35-38
    • /
    • 2010
  • The reports presents fire and life safety enhancements such as area of refuges, occupant evacuation elevators, fire resistance structure and etc that the high rise buildings other than general buildings should be applied. These enhancements is proposed for the high rise buildings in order to egress efficiently and safely.

  • PDF

Structural Design of Mid-Story Isolated High-Rise Building - Roppongi Grand Tower

  • Nakamizo, Daiki;Koitabashi, Yuichi
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.3
    • /
    • pp.233-242
    • /
    • 2018
  • Since the response reduction effect on over 200-meter-tall resulting from the seismic isolation system is smaller in general than low-rise and mid-rise buildings, mid-story isolated buildings are considered to reduce the response in the upper part above the isolation story, however, in many cases, the acceleration response just below the isolation story is likely to be the largest. This paper presents the structural design schemes, the design of the main structural frames, and the constructions of a 230-meter-tall super high-rise building with mid-story isolation mechanism integrated in Roppongi, Tokyo. Moreover, this paper shows how the architectural and structural design for integrating a mid-story isolation system in a super high-rise building has been conducted and what solutions have been derived in this project. The realization of this building indicates new possibilities for mid-story isolation design for super high-rise buildings.

A Study on the Fire Safety Design of High-Rise Apartment Buildings (초고층아파트의 화재안전성에 관한 건축계획적 연구)

  • 서동갑;장순익;이명호
    • Fire Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.23-30
    • /
    • 1991
  • One of the most serious national problems is the shortage of houses, especially in great cities. Housing shortage resulted from an overpopulated city brought the high-rise apartment buildings. While these buildings provide city-dwellers with much more houses, they have the basic fire safety problem in proportion to their heights. In these respect, this study aims to present the basic data for the fire safety design of high-rise apartment buildings. In this study, national fire damage statistics of past eleven years were investigated and the problem of the fire safety design of high-rise apartment buildings was studied through the methods of questions, observations and records on the representative six high-rise apartment buildings in seoul.

  • PDF

Historical Review on High-rise Buildings-promoting Policies on the Main Roads of Seoul for Urban Beautification from the 1950s to the 1970s (1950-1970년대 도시미화를 위한 서울 간선도로변 고층화제도의 사적 고찰)

  • Park, Ilhyang;Jeon, BongHee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.10
    • /
    • pp.41-52
    • /
    • 2019
  • The purpose of this study was to analyze the historical development of high-rise buildings-promoting policies in Seoul in terms of modern urban redevelopment. The results of this study were as follows; The maximum height of the buildings has been limited by National codes since 1934. But at the same time, Seoul Metropolitan government had limited the minimum building floors of roadside buildings through local regulations after the Korean War. The high-rise city had been regarded as a means of beautifying Seoul for a long time. However since the 2000s, the minimum height limit for buildings was removed from local regulations and the concept of high-rise restrictions was no longer significant as before.