• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.024 seconds

Consideration for Application of Wind Environment Assement on Ecological Parks in Cities (도시 생태공원의 풍환경 평가 적용에 관한 고찰)

  • Kim, Wonsul;Jung, Il Won;Kwon, Ji-Hye
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.117-122
    • /
    • 2019
  • City parks play an important role in reducing the air pollution and mitigating the city heat island effect caused by global warming. However, from July 2020, restricted parks over 20-year will be partially lifted due to sunset regulation on parks. As a result, the government and local governments have been making efforts to revitalize parks, such as creating ecological parks and securing park sites. However, building winds generated by high-rise buildings constructed around ecological parks in the city may cause discomfort to pedestrians and threaten the ecosystems of plants and animal that live in ecological parks. There are no clearly proposed as standards for wind environment assessment in Korea, but also it has been rarely studied on pedestrian wind environment. In this study, wind environment studies have been reviewed to find the important parameters related to wind environment assessment. Further, wind climate analysis using wind data obtained by Seoul meterological station was performed to examine the possibility of applicability of the wind environment assessment on the city ecological parks.

A Research for Identification Method of Sprayed Fire-Resistive Material by Thermal Analysis (열분석을 통한 내화 뿜칠재 일치성분석 연구)

  • Cho, Nam-Wook;Rie, Dong-Ho;Shin, Hyun-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • As recent buildings are getting more high-rise and larger, steel structures, not a reinforced concrete structure, for columns and beams among the main structural members in a building are being widely used. Steels used for the main members of a building are constructed with a fire-resistive structure by applying them with fire-resistive coatings. The introduction of a simple test method that can verify the performance of fire-resistive material constructed on a site without conducting a fire-resistant test(real scale fire test) is needed and this study derived a site analysis method possible to make a rapid and scientific analysis through the analysis of components (instrumental analysis) concerning tire-resistive materials. the possibility of application of it in analyzing congruence over site construction materials by recognizing it as a standard material after securing an inherent fingerprint area of tire-resistive materials of which performance was verified in the concrete through thermal analysis was proved through experiments. This research result can be minimize of casualties, who is harmed to building collapse according to structures fire.

Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms (수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 -)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Yeon, Jun Oh;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

Evaluation of inelastic performance of moment resisting steel frames designed by resizing algorithms (재분배 기법 적용에 따른 모멘트 저항골조의 비선형 특성 평가)

  • Seo, Ji Hyun;Kwon, Bong kwon;Park, Hyo Seon
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.3
    • /
    • pp.361-371
    • /
    • 2006
  • In recent years, to overcome drawbacks related to the aplicati on of classical structural optimization algorithms, various drift design methods based on factores of member displacement participation factors have been developed to size members if they satisfy stiffness criteria. In particular, a resizing algorithm based on dynamic displacement participation factors from the response spectrum analysis has been applied in the drift design of steel structures subjec ted to seismic lateral forces. In this aproach, active members are selected for displacement control based on the displacement participation fa ve members may be taken out and added to the active members for the drift control. The resizing algorithm can be practically and effectively applied to drift design of high-rise buildings however, the inelastic behavior o f the resizing algorithm has not ben evaluated yet. To develop the resizing algorithm considering the performance of nonlinearity as well a s elastic stifness, the evaluation model of resizing algorithm s is developed and aplied to the examples of moment-resisting steel frame, which is one of the simplest structural systems. The inelastic behavior of moment-resisting steel frame designed by the resizing algorithm is also discussed.

An Experimental Evaluation of Structural Performance for the Beam to Column Joints in Unit Modular System (유닛 모듈러 기둥-보 조인트의 구조 성능에 대한 실험적 평가)

  • Lee, Sang Sup;Bae, Kyu Woong;Park, Keum Sung;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2013
  • The major goal of this study is to develop the industrialized structural system that can build high-rise buildings using the box-shaped steel frames such as a unit module system. In order to achieve such a goal, we need the advanced details for joints that consist in a single unit. Furthermore we also need to commercialize the unit modular building system through the basic experiments, research of theoretical analysis and the achievement of seismic performance. This study derived to develop the derails in the beam-to-column joint and to carry out structural performance test. Test results, a joint with thickness of 6.0T can be possible to maintain the plastic rotational angle for strength and seismic performance. Therefore, joint with thickness of 6.0T is able to apply when considering reinforcement in the local of stress concentration.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

Performance assessment of multi-hazard resistance of Smart Outrigger Damper System (스마트 아웃리거 댐퍼시스템의 멀티해저드 저항성능평가)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.139-145
    • /
    • 2018
  • An outrigger system is used widely to increase the lateral stiffness of high-rise buildings, resulting in reduced dynamic responses to seismic or wind loads. Because the dynamic characteristics of earthquake or wind loads are quite different, a smart vibration control system associated with an outrigger system can be used effectively for both seismic and wind excitation. In this study, an adaptive smart structural control system based on an outrigger damper system was investigated for the response reduction of multi-hazards, including seismic and wind loads. A MR damper was employed to develop the smart outrigger damper system. Three cities in the U.S., L.A., Charleston, and Anchorage, were used to generate multi-hazard earthquake and wind loads. Parametric studies on the MR damper capacity were performed to investigate the optimal design of the smart outrigger damper system. A smart control algorithm was developed using a fuzzy controller optimized by a genetic algorithm. The analytical results showed that an adaptive smart structural control system based on an outrigger damper system can provide good control performance for multi-hazards of earthquake and wind loads.

Displacement Mapping for the Precise Representation of Protrusion (정확한 돌출 형상의 표현을 위한 변위매핑)

  • Yoo, Byoung-Hyun;Han, Soon-Hung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.10
    • /
    • pp.777-788
    • /
    • 2006
  • This paper describes a displacement mapping technique which represents protruded shapes on the surface of an object. Previous approaches for image-based displacement mapping can represent only shapes depressed from the polygon surface. The proposed technique can represent shapes protruded from the underlying surface in real-time. Two auxiliary surfaces which are perpendicular to the underlying surface are added along the boundary of the polygon surface, in order to represent the pixels which overflow over the boundary of the polygon surface. The proposed approach can represent accurate silhouette of protruded shape. It can represent not only smooth displacement of protruded shape, but also abrupt displacement such as perpendicular protrusion by means of adding the supplementary texture information to the steep surface of protruded shape. By per-pixel instructions on the programmable GPU this approach can be executed in real-time. It provides an effective solution for the representation of protruded shape such as high-rise buildings on the ground.

Improving GPS Vertical Error Using Barometric Altimeter (기압 고도계를 이용한 GPS 수직오차 개선)

  • Kim, La-Woo;Choi, Kwang-Ho;Lim, Joon-Hoo;Yoo, Won-Jae;Lee, Hyung-Keun
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • Accuracy of GPS (global positioning system) deteriorates dramatically or positioning is impossible in urban area occasionally since high-rise buildings and elevated roads make the reception of navigation signal very difficult so that number of visible satellites decreases. In these cases, vertical error usually becomes much larger than the horizontal error due to the intrinsic geometry of GPS satellites. To obtain more accurate and reliable height information, this paper proposes a hybrid method that combines GPS and a low-cost barometric altimeter. In the proposed method, the sea-level pressure and the sea-surface temperature are applied to the output of the altimeter. Next, the difference between the ellipsoid and the geoid is compensated. Finally, a simple Kalman filter combines the compensated barometric altitude and the GPS height. By static and car experiments, performance of the proposed method is evaluated. By the experiment results, it can be seen that the proposed method improves the altitude accuracy considerably.

Analysis of integrated GPS and GLONASS double difference relative positioning accuracy in the simulation environment with lots of signal blockage (신호차폐 시뮬레이션 환경에서의 통합 GPS/GLONASS 이중차분 상대측위 정확도 분석)

  • Lee, Ho-Seok;Park, Kwan-Dong;Kim, Du-Sik;Sohn, Dong-Hyo
    • Journal of Navigation and Port Research
    • /
    • v.36 no.6
    • /
    • pp.429-435
    • /
    • 2012
  • Although GNSS hardware and software technologies have been steadily advanced, it is still difficult to obtain reliable positioning results in the area with lots of signal blockage. In this study, algorithms for integrated GPS and GLONASS double difference relative positioning were developed and its performance was validated via simulations of signal blockages. We assumed that signal blockages are caused by high-rise buildings to the east, west, and south directions. And then, GPS-only and integrated GPS/GLONASS positioning accuracy was analysed in terms of 2-dimensional positioning accuracies. Compared with GPS-only positioning, the positioning accuracy of integrated GPS/GLONASS improved by 0.3-13.5 meters.