• Title/Summary/Keyword: high rate of loading

Search Result 612, Processing Time 0.026 seconds

Quasi-Static and Dynamic Loading Responses of Ti-6Al-4V Titanium Alloy: Experiments and Constitutive Modeling

  • Suh, Yeong-Sung;Akhtar S. Khan
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.191-194
    • /
    • 2003
  • The results from a systematic study of the response of a Ti-6Al-4V alloy under quasi-static and dynamic loading at different strain rates and temperatures are presented. It has been shown that the work-hardening rate decreased as the strain rate and the strain increased. The correlations and predictions using modified KHL (Khan-Huang-Liang) viscoplastic constitutive model are compared with those from JC (Johnson-Cook) model and experimental observations. Overall, KHL model correlations and predictions compared much more favorably than the corresponding JC model predictions and correlations.

  • PDF

Spatial Analysis of Nonpoint Source Pollutant Loading from the Imha dam Watershed using L-THIA (L-THIA를 이용한 낙동강수계 임하댐유역 비점오염원의 공간적 분포해석)

  • Jeon, Ji-Hong;Cha, Daniel K.;Choi, Donghyuk;Kim, Tae-Dong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.1
    • /
    • pp.17-29
    • /
    • 2013
  • Long-Term Hydrologic Impact Assessment (L-THIA) model which is a distributed watershed model was applied to analyze the spatial distribution of surface runoff and nonpoint source pollutant loading from Imha watershed during 2001~2010. L-THIA CN Calibration Tool linked with SCE-UA was developed to calibrate surface runoff automatically. Calibration (2001~2005) and validation (2006~2010) of monthly surface runoff were represented as 'very good' model performance showing 0.91 for calibration and 0.89 for validation as Nash-Sutcliffe (NS) values. Average annual surface runoff from Imha watershed was 218.4 mm and Banbyun subwatershed was much more than other watersheds due to poor hydrologic condition. Average annual nonpoint source pollutant loading from Imha wateshed were 2,295 ton/year for $BOD_5$, 14,752 ton/year for SS, 358 ton/year for T-N, and 79 ton/year for T-P. Amount of pollutant loading and pollutant loading rates from Banbyun watershed were much higher than other watersheds. As results of analysis of loading rate from grid size ($30m{\times}30m$), most of high 10 % of loading rate were generated from upland. Therefore, major hot spot area to manage nonpoint source pollution in Imha watershed is the combination of upland and Banbyun subwatershed. L-THIA model is easy to use and prepare input file and useful tool to manage nonpoint source pollution at screening level.

Dynamic Material Characteristics of Superalloy INCONEL 718 with the Variation of Strain Rates (변형률속도 변화에 따른 INCONEL 718 초내열합금의 동적 물성특성)

  • Song J. H.;Huh H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.275-278
    • /
    • 2005
  • INCONEL 718, nickel based superalloy, has good formability, high strength, excellent corrosion resistance and mechanical properties at high temperature. Owing to theses attractive properties, it finds use in applications such as combustion system, turbine engines and nuclear reactors. In such applications, components are typically required to be tolerant of high stress impact loading. This may cause material degradation and lead to catastrophic failure during service operation. In order to design optimal structural parts made of INCONEL 718, accurate understanding of material's mechanical properties, dynamic behavior and fracture characteristic as a function of strain rates are required. This paper concerned with the dynamic material properties of the INCONEL 718 for the various strain rates. The dynamic response of the INCONEL 718 at intermediate strain rate is obtained from the high speed tensile test machine test and at the high strain rate is from the split Hopkinson pressure bar test. Based on the experimental results, the effects of strain rate on dynamic flow stress, work hardening characteristics, strain rate sensitivity and elongation to the failure are evaluated. Experimental results from both quasi-static and high strain rate up to the 5000/sec are interpolated in order to construct the Johnson-Cook model as the constitutive relation that should be applied to simulate and design the structural parts made of INCONEL 718.

  • PDF

Dynamic Material Characteristics of Superalloy INCONEL 718 with the Variation of Strain Rates (변형률속도 변화에 따른 INCONEL 718 초내열합금의 동적 물성특성)

  • Song J. H.;Huh H.
    • Transactions of Materials Processing
    • /
    • v.14 no.6 s.78
    • /
    • pp.559-564
    • /
    • 2005
  • INCONEL 718, nickel based superalloy, has good formability, high strength, excellent corrosion resistance and mechanical properties at high temperature. Owing to theses attractive properties, it is utilized in applications such as combustion system, turbine engines and nuclear reactors. In such applications, components are typically required to be tolerant of high stress impact loading. This may cause material degradation and lead to catastrophic failure during service operation. Accurate understanding of material's mechanical properties with various strain rates is required in order to guarantee the reliability of structural parts made of INCONEL 718. This paper is concerned with the dynamic material properties of the INCONEL 718 at various strain rates. The dynamic response of the INCONEL 718 at the intermediate strain rate is obtained from the high speed tensile test and at the high strain rate is from the split Hopkinson pressure bar test. The effect of the strain rate on dynamic flow stress, work hardening characteristics, strain rate sensitivity and elongation to the failure is evaluated with the experimental results. Experimental results from both the quasi-static and the high strain rate up to 5000/sec are interpolated in order to construct the Johnson-Cook model as the constitutive relation that should be applied to simulate and design the structural parts made of rNCONEL 718.

A Review on Structural Behavior, Design, and Application of Ultra-High-Performance Fiber-Reinforced Concrete

  • Yoo, Doo-Yeol;Yoon, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.125-142
    • /
    • 2016
  • An overall review of the structural behaviors of ultra-high-performance fiber-reinforced concrete (UHPFRC) elements subjected to various loading conditions needs to be conducted to prevent duplicate research and to promote its practical applications. Thus, in this study, the behavior of various UHPFRC structures under different loading conditions, such as flexure, shear, torsion, and high-rate loads (impacts and blasts), were synthetically reviewed. In addition, the bond performance between UHPFRC and reinforcements, which is fundamental information for the structural performance of reinforced concrete structures, was investigated. The most widely used international recommendations for structural design with UHPFRC throughout the world (AFGC-SETRA and JSCE) were specifically introduced in terms of material models and flexural and shear design. Lastly, examples of practical applications of UHPFRC for both architectural and civil structures were examined.

Nitrification Efficiency of the Fluidized Sand Biofilter by TAN Leading Rates and Temperatures in the Simulated Seawater Aquaculture Condition (해수 조건에서 모래유동층 여과조의 TAN 부하량과 수온에 따른 질산화 효율)

  • Park, Jeong-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.6
    • /
    • pp.347-352
    • /
    • 2005
  • These experiments investigated the conditioning pattern and the nitrification efficiency of a fluidized sand biofilter (FSB) for seawater application. The FSB fed artificial nutrient was fully conditioned within 22 weeks. The maximum nitrification efficiency of the FSB was achieved at a superficial water velocity (SWV) of 1.0 cm/sec. After fixing the superficial water velocity at 1.0 cm/sec, the nitrification rates of the FSB were assessed at 3 total ammonia nitrogen (TAN) loading rates (250, 500, 1,000 g TAN/$m^3$/day) and 3 water temperatures (12, 16, $20^{\circ}C$). The TAN concentration in the simulated culture tank ranged from 2.87 to 9.72 mg/L at TAN loading rate of 1,000 g TAN/$m^3$/day, while that ranged from 0.45 to 1.26 mg/L at TAN loading rate of 500 g TAN/$m^3$/day. The ranges of TAN concentration in the former were too high for aquatic organisms and those in the latter were acceptable. Therefore, the safe TAN loading rate for the FSB in seawater conditions was decided as 500 g TA/$m^3$/day. From these results, daily TAN removal rates (g TAN/$m^3$/day) of FSB under conditions of inlet TAN concentration (C, mg/L) and water temperature (T, $^{\circ}C$) were calculated by the following non-linear multi-regression equation: TAN removal rate: f(z)=-1,311.295+655.714LnT+225.775LnC ($r^2=0.962$).

Study of using the loss rate of bolt pretension as a damage predictor for steel connections

  • Chui-Hsin Chen;Chi-Ming Lai;Ker-Chun Lin;Sheng-Jhih Jhuang;Heui-Yung Chang
    • Earthquakes and Structures
    • /
    • v.24 no.2
    • /
    • pp.81-90
    • /
    • 2023
  • The maximum drifts are important to the seismic evaluation of steel buildings and connections, but the information can hardly be obtained from the post-earthquake field investigation. This research studies the feasibility of using the loss rate of bolt pretension as an earthquake damage predictor. Full-scale tests were made on four steel connections using bolted-web-welded-flange details. One connection was unreinforced (UN), another was reinforced with double shear plates (DS), and the other two used reduced beam sections (RBS). The preinstalled strain gauges were used to control the pretensions and monitor the losses of the high-strength bolts. The results showed that the loss rate of bolt pretension was highly related to the damage of the connections. The pretensions lost up to 10% in all the connections at the yield drifts of 0.5% to 1%. After yielding of the connections, the pretensions lost significantly until fracture occurred. The UN and DS connections failed with a maximum drift of 4 %, and the two RBS connections showed better ductility and failed with a maximum drift of 6%. Under the far-field-type loading protocol, the loss rate grew to 60%. On the contrary, the rate for the specimen under near-fault-type loading protocol was about 40%. The loss rate of bolt pretension is therefore recommended to use as an earthquake damage predictor. Additionally, the 10% and 40% loss rates are recommended to predict the limit states of connection yielding and maximum strength, respectively, and to define the performance levels of serviceability and life-safety for the buildings.

Evaluation of Properties of 80, 130, 180 MPa High Strength Concrete at High Temperature with Heating and Loading (고온가열 및 하중재하에 따른 80, 130, 180 MPa 초고강도콘크리트의 역학적특성평가)

  • Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Tae-Gyu;Lee, Seong-Hun;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.613-620
    • /
    • 2013
  • Concrete has been recognized as a material which is resistant to high temperatures, but chemicophysical property of concrete is changed by the high temperature. So, mechanical properties of concrete may be reduced. Because of this, standards and researches on the degradation of the mechanical properties of concrete at high temperatures have been presented. However, research data about the state that considering the loading condition and high-strength concrete is not much. Therefore, this study evaluated the high-temperature properties of high-strength concrete by loading condition and elevated temperature. The stress-strain, strain at peak stress, compressive strength, elastic modulus, thermal strain and the transient creep are evaluated under the non-loading and $0.25f_{cu}$ loading conditions on high strength concrete of W/B 12.5%, 14.5% and 20%. Result of the experiment, decrease in compressive strength due to high temperature becomes larger as the compressive strength increases, and residual rate of elastic modulus and compressive strength is high by the shrinkage caused by loading and thermal expansion due to high temperature are offset from each other, at a temperature above $500^{\circ}C$.

pH-Controlled Synthesis of Cephalexin by a Purified Acetobacter turbidans Ampicillin Acylase

  • Nam, Doo-Hyun;Ryu, Yeon-Woo;Dewey D.Y Ryu
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.329-332
    • /
    • 2001
  • It has been known that, in enzymatic synthesis of cephalexin, the conversion yield was reduced by high loading of ampicillin acylase. In order to elucidate this phenomena, pH-controlled synthesis of cephalexin was examined using a purified Acetobacter turbidans acylase. When the pH of the reaction mixture was maintained at $6.20{\pm}0.04$, the reduction of the maximal conversion rate was not observed even with high enzyme loading. The kinetic parameters also suggest that pH drop during the enzymatic synthesis of cephalexin was mainly attributed to the rapid hydrolysis of D-${\alpha}$-phenylglycine methyl ester to D-${\alpha}$-phenylglycine, rather than the disappearance of 7-amino-3-deacetoxycephalosporanic acid for cephalexin synthesis. At higher molar ratio of two substrates, [D-${\alpha}$-phenylglycine methyl ester]/[7-amino-3-deacetoxycephalosporanic acid], the conversion rate was also elevated under pH-controlled enzymatic synthesis, which implies that the main reason for the pH drop is due to the production of D-${\alpha}$-phenylglycine methyl easter, the effect of a water-methanol cosolvent system on the ester, the effect of a water-methanol cosolvent system on the conversion profile was also examined. Even the though the conversion rate was increased in 10% methanol solution, a higher than 16% methanol in the reaction mixture caused an inactivation of enzyme.

  • PDF

Freeze Casting of Aqueous Alumina/Silicon Carbide Slurries and Fabrication of Layered Composites: (I) Dispersion and Rheology of Slurries (수성 알루미나/탄화규소 슬러리의 동결주조와 층상복합체의 제조: (I) 슬러리의 분산과 유동성)

  • Yang, Tae-Young;Cho, Yong-Ki;Kim, Young-Woo;Yoon, Seog-Young;Park, Hong-Chae
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.2
    • /
    • pp.99-104
    • /
    • 2008
  • Zeta potential, sedimentation bulk density and rheology in the dispersion system have been studied in terms of solid loading (40-55 vol%), and types of additives. Ammonium polymethacrylate, glycerol, ethoxylated acetylenic diol, and polyvinyl alcohol have been used as the dispersant, cryo-protectant, surfactant, and binder, respectively. Sedimentation density greatly increased upon adding dispersant; the effect was more pronounced with ionic alumina suspension compared with covalent silicon carbide. With further addition of cryo-protectant and surfactant to dispersant, the sedimentation density increased somewhat. The suspension viscosity generally behaviored in an opposite manner to the sedimentation density, i.e., high sedimentation gave low high-shear viscosity, indicative of low order structure formation in the suspended particles. Shear rate rheology in shear rate of $2-300\;sec^{-1}$ showed a shear thinning and its onset began at similar shear rate (${\sim}100\;sce^{-1}$), regardless of solid loading.