• Title/Summary/Keyword: high pressure water jet

Search Result 79, Processing Time 0.029 seconds

Development of a Garlic Peeling System Using High-Pressure Water Jets (IV) - Structure and performance of a full-scale system in operation - (습식 마늘박피 시스템 개발 (IV) - 상업용 시스템의 구조와 성능 -)

  • Bae Y. H.;Yang K. W.;Baik S. K.;Kim J.;Chang Y. C.;Lee S. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.25-31
    • /
    • 2005
  • There are more than three hundred garlic peeling facilities in Korea and most of them use pressurized air for skin peeling operation. One of the major problems of using air for the peeling operation is the occurrence of excessive bruises on the flesh of peeled garlic which causes easy microbial contamination and shortening of the shelf lift. To reduce the occurrence of bruises during the peeling operation, a new type of garlic peeling system was developed which use pressurized water. In this system, high pressure water jets were used to separate garlic bulbs and to peel the skin of garlic cloves. Six commercial systems of this type had been developed and installed at several locations in Korea. The design and performance of the latest system according to three pressure levels were described in this paper. Peeling efficiency of the system was as high as $64.7\%$ in one cycle of peeling operation by three chambers installed in series. Incorporation of a sorting system based on machine vision and re-circulation of unpeeled and partially-peeled garlic enhanced peeling efficiency by additional $30\%$, resulting in total peeling efficiency of the final products of approximately $95\%$. Peeling capacity of the system was over 400 kg per hour.

Development of ROV Trencher URI-T and its Sea Trial (URI-T, 해저 케이블 매설용 ROV 트렌처 개발 및 실해역 성능 검증)

  • Kang, Hyungjoo;Lee, Mun-Jik;Cho, Gun Rae;Ki, Geonhui;Kim, Min-Gyu;Li, Ji-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.300-311
    • /
    • 2019
  • An ROV trencher is a type of heavy-duty work class ROV equipped with high-pressure water jet tools for cutting into the sea floor and burying cables. This kind of trencher is mostly used for PLIB operations. This paper introduces the development of this kind of ROV trencher, which has a 698 kW power system, with a 250 kW hydraulic system and two 224 kW water jet systems. The project was launched in January 2014. After four years of design, manufacturing, and system integration, we carried out two sea trials near the Yeongilman port (about 20-30 m in depth) in Pohang to evaluate the system performance in November 2017 and August 2018. Through tests, we found that most of specifications were satisfied, including a maximum bury depth of 3 m, maximum bury speed of 2 km/h, and maximum forward speed of 1.54 m/s.

Keyhole-structure and Stability in Laser-beam Penetration Into an Absorbing Liquid (Water) (레이저 빔의 흡수 액체 내 침투에 의해 생성된 키홀 구조와 안정성)

  • 김동식;장덕석
    • Laser Solutions
    • /
    • v.4 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • When a high-power laser beam is irradiated on the surface of material, it is well known that a cavity, called a keyhole induced by the pressure action of the vapor plume, is generated in the molten material. This paper describes the interaction between a pulsed CO$_2$ laser beam and water. The laser-beam is used to generate and maintain a conical depression in the water surface similar to the keyhole created during laser penetration welding. Experimental results show that the depth of laser-beam penetration is limited by hydrodynamic instability. The instability of the surface cavity can be understood by the capillary instability of a hollow jet. Theoretical computation of the steady keyhole shape has been performed. modifying the model suggested by Andrews et al. (1976). The model predicts the qualitative behavior of the keyhole but significantly underestimates the average diameter.

  • PDF

Comparison of SpineJet$^{TM}$ XL and Conventional Instrumentation for Disk Space Preparation in Unilateral Transforaminal Lumbar Interbody Fusion

  • Huh, Han-Yong;Ji, Cheol;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.370-376
    • /
    • 2010
  • Objective : Although unilateral transforaminal lumbar interbody fusion (TLIF) is widely used because of its benefits, it does have some technical limitations. Removal of disk material and endplate cartilage is difficult, but essential, for proper fusion in unilateral surgery, leading to debate regarding the surgery's limitations in removing the disk material on the contralateral side. Therefore, authors have conducted a randomized, comparative cadaver study in order to evaluate the efficiency of the surgery when using conventional instruments in the preparation of the disk space and when using the recently developed high-pressure water jet system, SpineJet$^{TM}$ XL. Methods : Two spine surgeons performed diskectomies and disk preparations for TLIF in 20 lumbar disks. All cadaver/surgeon/level allocations for preparation using the SpineJet$^{TM}$ XL (HydroCision Inc., Boston, MA, USA) or conventional tools were randomized. All assessments were performed by an independent spine surgeon who was unaware of the randomizations. The authors measured the areas (cm2) and calculated the proportion (%) of the disk surfaces. The duration of the disk preparation and number of instrument insertions and withdrawals required to complete the disk preparation were recorded for all procedures. Results : The proportion of the area of removed disk tissue versus that of potentially removable disk tissue, the proportion of the area of removed endplate cartilage, and the area of removed disk tissue in the contralateral posterior portion showed 74.5 ${\pm}$ 17.2%, 18.5 ${\pm}$ 12.03%, and 67.55 ${\pm}$ 16.10%, respectively, when the SpineJet$^{TM}$ XL was used, and 52.6 ${\pm}$ 16.9%, 22.8 ${\pm}$ 17.84%, and 51.64 ${\pm}$ 19.63%, respectively, when conventional instrumentations were used. The results also showed that when the SpineJet$^{TM}$ XL was used, the proportion of the area of removed disk tissue versus that of potentially removable disk tissue and the area of removed disk tissue in the contralateral posterior portion were statistically significantly high (p < 0.001, p < 0.05, respectively). Also, compared to conventional instrumentations, the duration required to complete disk space preparation was shorter, and the frequency of instrument use and the numbers of insertions/withdrawals were lower when the SpineJet$^{TM}$ XL was used. Conclusion : The present study demonstrates that hydrosurgery using the SpineJet$^{TM}$ XL unit allows for the preparation of a greater portion of disk space and that it is less traumatic and allows for more precise endplate preparation without damage to the bony endplate. Furthermore, the SpineJet$^{TM}$ XL appears to provide tangible benefits in terms of disk space preparation for graft placement, particularly when using the unilateral TLIF approach.

Experimental Study on Characteristics of Steam Condensation in a Sub-cooled Water Pool (과냉각수조에서 증기응축 특성에 관한 실험적 연구)

  • Kim, Hwan-Yeol;Cho, Seok;Song, Chul-Hwa;Chung, Moon-Ki;Choi, Sang-Min
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.298-308
    • /
    • 1999
  • Experimental study on characteristics of direct contact condensation of steam discharged into a sub-cooled water pool has been performed using five different sizes of horizontal nozzle over a wide range of steam mass fluxes and pool temperatures. Steam condensation phenomena have been observed visually and by taking pictures of steam jets using a high speed video camera. Two different steam jet shapes such as ellipsoidal shape and conical shape were typically observed for a stable steam jet, depending on the steam mass flux and pool temperature. The steam jet expansion ratio and the steam jet length as well as the condensation heat transfer coefficients were determined. The effect of steam mass flux, pool temperature, and nozzle diameter on these parameters were also discussed. Empirical correlations for the steam jet lengths and the condensation heat transfer coefficients as a function of steam mass flux and condensation driving potential were established. The axial and radial temperature distributions in steam jet and in surrounding water were measured. The effect of steam mass flux, pool temperature, and nozzle diameter were also discussed. The condensation regime map, which consists of six regimes such as chugging, transient chugging, condensation oscillation, stable condensation, bubble condensation oscillation, and intermittent oscillation condensation, were established. In addition, the dynamic pressures at the pool wall were measured. The close relation of dynamic pressure and steam condensation mode, which is also dependent on steam mass flux and pool temperature, was found.

  • PDF

Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet (초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가)

  • Kim, Hyun-Jin;Park, Il-gun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • A road structure washing vehicle equipped with a 4 HP, 80 LPM ultrafine bubble generator was used to clean a tunnel wall and the surface of the surrounding structure, consisting of concrete and tiles, in a heavy traffic area around an apartment complex in the city. Ultrafine bubbles were generated by supplying air at 2 to 3 LPM and using a specially designed nozzle, whereas fine bubbles made by an impeller in a gas-liquid mixing self-priming pump were produced with an average diameter of 165.4 nm and 6.81 × 107 particles mL-1. Using a high pressure washer gun that can perform high-pressure cleaning at 150 bar and 30 LPM, ultrafine bubbles were used to wash dust adsorbed on the surface of the road structures. The experimental analysis was divided into before and after washing. The samples were analyzed by applying ISO 8502-3 to measure surface contamination of dust adsorbed on the surface. Using the transparent tape attached to the surface, the removal rate was calculated by measuring the weight of the dust, and the number of particles was calculated using the gravimetric method and the software, ImageJ. The results of the experiment showed that the number of dust particles adsorbed on the tile wall surface before and after washing were 3,063 ± 218 particles mL-1 and 20 ± 5 particles mL-1, respectively, with weights of 580 ± 82 mg and 13 ± 4 mg. Particles on the surface of the concrete structure before and after washing were 8,105 ± 1,738 particles mL-1 and 39 ± 6 particles mL-1, respectively, with weights of 1,448 ± 190 mg and 118 ± 32 mg.

Quantitative Vapor Phase Exciplex Fluorescence Measurements at High Ambient Temperature and Pressure

  • Kim, Tongwoo;Jaal B. Ghandhi
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.157-167
    • /
    • 2003
  • The exciplex fluorescence technique with the TMPD (tetamethyl-Ρ-phenylene-diamine) / naphthalene dopant system was applied in a combustion-type constant-volume spray chamber. A detailed set of calibration experiments has been performed in order to quantify the TMPD fluorescence signal. It has been demonstrated that the TMPD fluorescence intensity was directly proportional to concentration, was independent of the chamber pressure, and was not sensitive to quenching by either water vapor or carbon dioxide. Using a dual heated-jet experiment, the temperature dependence of TMPD fluorescence up to 1000 K was measured. The temperature field in the spray images was determined using a simple mixing model, and an iterative solution method was used to determine the concentration and temperature field including the additional effects of the laser sheet extinction. The integrated fuel vapor concentration compared favorably with the measured amount of injected fuel when all of the liquid fuel had evaporated.

An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube (수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구)

  • Seal, Sin-Su;Lee, Sang-Yang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

Evaluation of Effectiveness of Vacuum Oral Cleaner Developed for Patients with Limited Mobility

  • Lee, Jae-Hyun;Jung, Ki-Won;Kim, Hee-Kyung;Koo, Ki-Tae;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.54 no.12
    • /
    • pp.1035-1044
    • /
    • 2016
  • Purpose : The purpose of this study was to compare the plaque removal effects of vacuum oral cleaner developed for the patients with limited mobility with those of manual toothbrushes and high pressure injection oral cleaner (dental water jet). Meterials and methods : Thirty human subjects were measured with Patient Hygiene Performance index (PHP index) and O'Leary index before and after the use of toothbrush, high pressure injection oral cleaner and vacuum oral cleaner. These three different oral hygiene methods were conducted with seven-day intermittence. Then the statistical analysis was carried out to define plaque removal rate of three different oral hygiene methods (${\alpha}=.05$). Results : According to the efficacy analysis of plaque removal before and after the oral cleaning using each of three methods, significant reduction in plaque after the treatment compared to the previous state when using toothbrush, high pressure injection oral cleaner, and vacuum oral cleaner was observed (P < 0.001). PHP index of tooth brushing was higher than that of the high pressure injection oral cleaner, while PHP index of vacuum oral cleaner did not show significant difference from either of the other two methods. There was no significance difference in O'Leary index among the three methods. Conclusion : Effect of plaque removal using the vacuum oral cleaner is comparable to that of manual tooth brush or high pressure injection oral cleaner, so it will be helpful for self-oral hygiene care of the patients with limited mobility.

  • PDF

Steam Explosion Experiments using ZrO$_2$ (ZrO$_2$를 이용한 증기폭발 실험)

  • Song, Jin-Ho;Kim, Hui-Dong;Hong, Seong-Wan;Park, Ik-Gyu;Sin, Yong-Seung;Min, Byeong-Tae;Kim, Jong-Hwan;Jang, Yeong-Jo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1887-1897
    • /
    • 2001
  • Korea Atomic Energy Research Institute (KAERI) launched an intermediate scale steam explosion experiment named "Test for Real Corium Interaction with water (TROI)" using reactor material to investigate whether the molten reactor material would lead to energetic steam explosion when interacted wish cold water at low pressure. The melt-water interaction experiment is performed in a pressure vessel with the multi-dimensional fuel and water pool geometry. The novel concept of cold crucible technology, where powder of the reactor material in a water-cooled cafe is heated by high frequency induction, is firstly implemented for the generation of molten fuel. In this paper, the lest facility and cold crucible technology are introduced and the results or the first series of tests were discussed. The 5 kg of molten ZrO$_2$jet was poured into the 67cm deep water pool at 30 ∼ 95 $\^{C}$. Either spontaneous steam explosions or quenching was observed. The morphology of debris and pressure wave profiles clearly indicate the differences between the two cases.