• 제목/요약/키워드: high pressure discharge

Search Result 511, Processing Time 0.024 seconds

Synthesis of size-controlled ZnO tetrapods sizes using atmospheric microwave plasma system and evaluation of its photocatalytic property (대기압 마이크로웨이브 플라즈마를 이용한 다양한 크기의 ZnO tetrapod 합성 및 광촉매 특성 평가)

  • Heo, Sung-Gyu;Jeong, Goo-Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.340-347
    • /
    • 2021
  • Among various metal oxide semiconductors, ZnO has an excellent electrical, optical properties with a wide bandgap of 3.3 eV. It can be applied as a photocatalytic material due to its high absorption rate along with physical and chemical stability to UV light. In addition, it is important to control the morphology of ZnO because the size and shape of the ZnO make difference in physical properties. In this paper, we demonstrate synthesis of size-controlled ZnO tetrapods using an atmospheric pressure plasma system. A micro-sized Zn spherical powder was continuously introduced in the plume of the atmospheric plasma jet ignited with mixture of oxygen and nitrogen. The effect of plasma power and collection sites on ZnO nanostructure was investigated. After the plasma discharge for 10 min, the produced materials deposited inside the 60-cm-long quartz tube were obtained with respect to the distance from the plume. According to the SEM analysis, all the synthesized nanoparticles were found to be ZnO tetrapods ranging from 100 to 600-nm-diameter depending on both applied power and collection site. The photocatalytic efficiency was evaluated by color change of methylene blue solution using UV-Vis spectroscopy. The photocatalytic activity increased with the increase of (101) and (100) plane in ZnO tetrapods, which is caused by enhanced chemical effects of plasma process.

Influencing factors for Sleep Disturbance in the Intensive Care Unit Patients: A Systematic Review (중환자실 환자의 수면에 영향을 미치는 요인: 체계적 고찰)

  • Cho, Young Shin;Joung, Sunae
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : Sleep disturbances in patients in the intensive care unit (ICU) are related to health problems after discharge. Therefore, active prevention and management are required. Hence, identification of the factors that affect sleep in patients who are critically ill is necessary. Methods : The PubMed, Cochrane Library, CINAHL, EMBASE, and Web of Science databases were searched. Selection criteria were observational and experimental studies that assessed sleep as an outcome, included adult patients admitted to the ICU, and published between November 2015 and April 2022. Results : A total of 21,136 articles were identified through search engines and manual searches, and 42 articles were selected. From these, 22 influencing factors and 11 interventions were identified. Individual factors included disease severity, age, pain, delirium, comorbidities, alcohol consumption, sex, sleep disturbance before hospitalization, chronic obstructive pulmonary disease (COPD), cardiovascular disease, and high diastolic blood pressure (DBP), low hemoglobin (Hb), and low respiratory rate (RR). Environmental factors included light level, noise level, and temperature. Furthermore, treatment-related factors included use of sedatives, melatonin administration, sleep management guidelines, ventilator application, nursing treatment, and length of ICU stay. Regarding sleep interventions, massage, eye mask and earplugs, quiet time and multicomponent protocols, aromatherapy, acupressure, sounds of the sea, adaptive intervention, circulation lighting, and single occupation in a room were identified. Conclusion : Based on these results, we propose the development and application of various interventions to improve sleep quality in patients who are critically ill.

Predictors of Long-term Mortality after Hospitalization for Acute Exacerbation of COPD (만성폐쇄성폐질환의 급성악화로 입원했던 환자에서 장기간 사망의 예측인자)

  • Jung, Hae-Seon;Lee, Jin Hwa;Chun, Eun Mi;Moon, Jin Wook;Chang, Jung Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.205-214
    • /
    • 2006
  • Background : Acute exacerbations form a major component of the socioeconomic burden of COPD. As yet, little information is available about the long-term outcome of patients who have been hospitalized with acute exacerbations, although high mortality rates have been reported. The aim of this study was to determine predictors of long-term mortality after hospitalization for acute exacerbation of COPD. Methods : We performed a retrospective cohort study of consecutive patients admitted to the hospital for COPD exacerbation between 2000 through 2004. Patients who had died in hospital or within 6-months after discharge, had tuberculosis scar, pleural thickening or bronchiectasis by chest radiography or had been diagnosed with malignancy during follow-up periods were excluded. Results : Mean age of patients was 69.5 years, mean follow-up duration was 49 months, and mean $FEV_1$ was 1.00L (46% of predicted). Mortality was 35% (17/48). In the multivariate Cox regression analysis, heart rate of 100/min or more (p=0.003; relative risk [RR], 11.99; 95% confidence interval [CI], 2.34-61.44) and right ventricular systolic pressure (RVSP) of 35mmHg or more (p=0.019; RR, 6.85; 95% CI, 1.38-34.02) were independent predictors of mortality. Conclusion : Heart rate and RVSP in stable state may be useful in predicting long-term mortality for COPD patients admitted to hospital with acute exacerbation.

Dynamics of Attached Microbial Community on the River with Gravel Riverbed (자갈하상 하천에서 부착미생물군집의 거동)

  • Park, Jae-Young;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.235-244
    • /
    • 2005
  • This study was carried out in Osan river to quantitatively investigate behavior of attacked microbial community (AMC) for enhancing self-purification process of river. We gained the results such as follows throughout long-term monitoring at in-situ river. The biomass of AMC had higher in the riffle than the almost stagnant pool and they were more developed in the riffle with high current velocity (HCV). Although the fast flowing current affects negatively to growth of the AMC during the early phase when the community gets attached to the benthic substrate, it was observed that it affected positively to their growth during the intermediate and later phase after the community is adapted to the substrate. When turbulence due to external pressure (storm or discharge of dam and reservoir) occurs, the degree of separation depends upon the flowing strength and the type of the external pressure. Since the community is not all separated, recovery is rather fast. Therefore, this study found that the degree of reduction of the pollutant by self-purification of the stream is depended upon the riverbed shape and the AMC contributes to self-purification positively or negatively in river. Therefore, the riverbed shape must be constructed in accordance with the characteristics of water quality in stream. Furthermore, the technique of installing the water channel structure appropriate for each section must be developed to maximize self-purification ability.

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

A study of the space sterilization device using atmospheric-pressure DBDs plasma (대기압 유전체장벽방전을 적용한 플라즈마오존 공간살균장치에 관한 연구)

  • Oh, Hee-Su;Lee, Kang-yeon;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.281-289
    • /
    • 2022
  • Plasma ozone is utilized in a variety of applications in the field of sterilization due to its high sterilization performance. Dielectric materials used in DBD(dielectric barrier discharges) are mainly polymer, quartz and ceramics. These dielectric layers have the advantage of limiting the amount of supplied electron charge and allowing plasma to occur evenly on the surface of dielectric. Actually, the target or environment for sterilization is often a complex structure, so research and academic study are needed by utilizing the concept of space sterilization. In this study, the device is applied to generate DBD plasma at atmospheric pressure for disinfection due to the effectiveness in producing radicals and ozone. The generator of plasma ozone is a basic structure of dielectric barrier discharge by placing ceramic tube dielectrics and stainless steel electrical conductors at regular intervals. Various applications can be developed based on the proposed design method. Plasma ozone generation for space sterilization device is recognized as an excellent sterilization device. Through the design and verification of the device, we intend to establish an optimal design of the spatial sterilization device and provide the basis data for sterilization applications.

Spatting and Fire Enduring Properties of High Strength RC Column Subjected to Axial Load Depending on Fiber Contents (중심 축하중을 받는 고강도 RC기둥의 섬유 혼입량에 따른 폭열 및 내화 성상)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Lee, Jae-Sam;Kim, Kyoung-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.83-90
    • /
    • 2006
  • This paper investigates experimentally the fire resistance performance and spatting resistance of high performance reinforced concrete column member subjected to fire containing polypropylene fiber(PP fiber) and cellulose fiber(CL fiber). An increase in PP fiber and CL fiber contents, respectively resulted in a reduction of fluidity due to fiber ball effect. Air content is constant with m increase in fiber content. Compressive strength reached beyond 50 MPa. Based on fire resistance test, severe failure occurred with control concrete specimen, which caused exposure of reinforcing bar. No spall occurred with specimen containing PP fiber. This is due to the discharge of internal vapour pressure. Use of CL fiber superior to control concrete in the side of spatting resistance, localized failure at comer of specimen was observed. Corner of specimen had deeper neutralization than surface of specimen. Specimen containing PP fiber had the least damaged area due to spatting. Neutralization depth ranged between 6 and 8 mm Residual compressive strength of specimen containing PP fiber maintained 40%, which is larger than control concrete with 20% of residual strength. Specimen containing CL fiber had 25% or residual strength.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

A Study on Differences of Opinions on Home Health Care Program among Physicians, Nurses, Non-medical personnel, and Patients. (가정간호 사업에 대한 의사, 간호사, 진료관련부서 직원 및 환자의 인식 비교)

  • Kim, Y.S.;Lim, Y.S.;Chun, C.Y.;Lee, J.J.;Park, J.W.
    • The Korean Nurse
    • /
    • v.29 no.2
    • /
    • pp.48-65
    • /
    • 1990
  • The government has adopted a policy to introduce Home Health Care Program, and has established a three stage plan to implement it. The three stage plan is : First, to amend Article 54 (Nurses for Different Types of Services) of the Regulations for Implementing the Law of Medical Services; Second, to tryout the new system through pilot projects established in public hospitals and clinics; and third, to implement at all hospitals and equivalent medical institutions. In accordance with the plan, the Regulation has been amend and it was promulgated on January 9,1990, thus establishing a legal ground for implementing the policy. Subsequently, however, the Medical Association raised its objection to the policy, causing a delay in moving into the second stage of the plan. Under these circumstances, a study was conducted by collecting and evaluating the opinions of physicians, nurses, non-medical personnel and patients on the need and expected result from the home health care for the purpose of help facilitating the implementation of the new system. As a result of this study, it was revealed that: 1. Except the physicians, absolute majority of all other three groups - nurses, non-medical personnel and patients -gave positive answers to all 11 items related to the need for establishing a program for Home Health Care. Among the physicians, the opinions on the need for the new services were different depending on their field of specialty, and those who have been treating long term patients were more positive in supporting the new system. 2. The respondents in all four groups held very positive view for the effectiveness and the expected result of the program. The composite total of scores for all of 17 items, however, re-veals that the physicians were least positive for the- effectiveness of the new system. The people in all four groups held high expectation on the system on the ground that: it will help continued medical care after the discharge from hospitals; that it will alleviate physical and economic burden of patient's family; that it will offer nursing services at home for the patients who are suffering from chronic disease, for those early discharge from hospital, or those who are without family members to look after the patients at home. 3. Opinions were different between patients( who will receive services) and nurses (who will provide services) on the types of services home visiting nurses should offer. The patients wanted "education on how to take care patients at home", "making arrangement to be admitted into hospital when need arises", "IV injection", "checking blood pressure", and "administering medications." On the other hand, nurses believed that they can offer all 16 types of services except "Controlling pain of patients", 4. For the question of "what types of patients are suitable for Home Health Care Program; " the physicians, the nurses and non-medical personnel all gave high score on the cases of "patients of chronic disease", "patients of old age", "terminal cases", and the "patients who require long-term stay in hospital". 5. On the question of who should control Home Health Care Program, only physicians proposed that it should be done through hospitals, while remaining three groups recommended that it should be done through public institutions such as public health center. 6. On the question of home health care fee, the respondents in all four groups believed that the most desireable way is to charge a fixed amount of visiting fee plus treatment service fee and cost of material. 7. In the case when the Home Health Care Program is to be operated through hospitals, it is recommended that a new section be created in the out-patient department for an exclusive handling of the services, instead of assigning it to an existing section. 8. For the qualification of the nurses for-home visiting, the majority of respondents recommended that they should be "registered nurses who have had clinical experiences and who have attended training courses for home health care". 9. On the question of if the program should be implemented; 74.0% of physicians, 87.5% of non-medical personnel, and 93.0% of nurses surveyed expressed positive support. 10. Among the respondents, 74.5% of -physicians, 81.3% of non-medical personnel and 90.9% of nurses said that they would refer patients' to home health care. 11. To the question addressed to patients if they would take advantage of home health care; 82.7% said they would if the fee is applicable to the Health Insurance, and 86.9% said they would follow advises of physicians in case they were decided for early discharge from hospitals. 12. While 93.5% of nurses surveyed had heard about the Home Health Care Program, only 38.6% of physicians surveyed, 50.9% of non-medical personnel, and 35.7% of patients surveyed had heard about the program. In view of above findings, the following measures are deemed prerequisite for an effective implementation of Home Health Care Program. 1. The fee for home health care to be included in the public health insurance. 2. Clearly define the types and scope of services to be offered in the Home Health Care Program. 3. Develop special programs for training nurses who will be assigned to the Home Health Care Program. 4. Train those nurses by consigning them at hospitals and educational institutions. 5. Government conducts publicity campaign toward the public and the hospitals so that the hospitals support the program and patients take advantage of them. 6. Systematic and effective publicity and educational programs for home heath care must be developed and exercises for the people of medical professions in hospitals as well as patients and their families. 7. Establish and operate pilot projects for home health care, to evaluate and refine their programs.

  • PDF

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.