• Title/Summary/Keyword: high organic wastewater

Search Result 443, Processing Time 0.022 seconds

Determination of the Origin of Particulate Organic Matter at the Estuary of Youngsan River using Stable Isotope Ratios (${\delta}^{13}C$, ${\delta}^{15}N$) (탄소 및 질소 안정동위원소 비를 이용한 영산강하구역 유기물 기원 추정 연구)

  • Lee, Yeon-Jung;Jeong, Byung-Kwan;Shin, Yong-Sik;Kim, Sung-Hwan;Shin, Kyung-Hoon
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2013
  • Organic carbon and total nitrogen stable isotope ratios of suspended materials were determined at 3 stations (from Mongtan Bridge to Youngsan river estuary barrage) (n=6, each) from November 2008 to August 2009, in order to understand the origin of particulate organic matter at the Estuary of Youngsan River. Allochthonous organic matter, ammonia-N and silicate were increased after heavy rain (in August). Carbon isotope ratios were significantly different between stations in November and August, and it was possible to determine the origin of organic matter. The heavier nitrogen isotope ratios, as well as higher phosphate concentrations, were found in November than other sampling times. Livestock wastewater and farmland input was likely the main causes of these high values. In addition, YS3 station, the nearest site to estuary barrage, appears to be affected by a substantial amount of livestock wastewater and farmland input, considering that nitrogen isotope ratios were heavier than those at the upper sites. These results suggest that the analysis of stable isotope ratios is a simple but useful tool for the determination of organic matter origin in aquatic environments.

A Study on the Treatment of a High-Strength Organic Wastewater by the Tube Type Fixed Biofilter Process (엔통형 고정상 생물막법에 의한 고농도 유기성 폐수처리에 관한 연구)

  • 손종렬;장명배;문경환
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.2
    • /
    • pp.22-27
    • /
    • 1994
  • This study is to discuss the factors influenced on the removal efficiency of a high-strength organic wastewaters investigated using the polypropyrene media which appropriate to attach microorganism in the tube type fixed biofilter reactor. The results obtained in the experiment were as follows: 1. The kinetics of reaction rate (k') were 0.125, 0.135, 0.155 varing initial COD 720, 1280, 1630 mg/l in batch reactor. 2. In the range of pH 4.0 ~12.0 was obtained the removal efficiency of COD higher than 85%. It was proved that variation of pH (4.0 ~12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 3. Temperature to obtain removal efficiency of COD higher than 85% was 10 ~ 40$\circ$C. Removal efficiency of COD was no less than those at high temperature. 4. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/m$^3$.d below. And then the HRT was 8 hrs. 5. In comparison with the activated sludge process, the tube type fixed biofilter process was excellent in removal efficiency of substrate and sludge production rate.

  • PDF

Estimation of Decomposition Capacity for Organic Matter in Tidal Flat Sediments at Saemankeum Area (새만금지역 하구갯벌의 유기물 분해능력 평가)

  • Jong-Gu Kim;Sun-Jae You
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.315-321
    • /
    • 2001
  • This study was conducted to estimate the decomposition capacity for organic matter by microbe of tidal flat sediments (Hajae, Dongjin and Mankyung). The decomposition rate constants (K') have been determined by Thomas slope method and compared with the values of each tidal flats. The decomposition rates of organic matter by microbe were initially very slow, but at the end of 12 hours, very sharply increased. The values of decomposition rate constant for Dongjin, Mankyung and Hajae tidal flat sediment were 1.364$day^{-1}$/, 1.080d$day^{-1}$ and 0.735$day^{-1}$, respectively. The decomposition rate constant of Dongjin tidal flat sediment which affected by livestock wastewater was higher than others. The decomposition quantity (mg/g/day) of organic matter by microbe of tidal flat sediments was 0.4mg/g/day for Dongjin, 0.36mg/g/day for Mankyung and 0.36mg/g/day for Hajae. The average of decomposition quantity was 0.37mg/g/day. To calculate purification capacity (kg/ha) of organic matter by microbe, we applied to two assumption ; 1) biological action by microbe is occur within 0.1cm under surface 2) specific gravity of sediment are 2.5g/$\textrm{cm}^2$. The purification capacity of organic matter by microbe of tidal flat sediment was calculated to 9.25kg/ha. The relationships between decomposition rate constant (K') and ignition loss (I. L), chemical oxygen demand by sediment (CO $D_{sed}$), total carbon(TC), silt and clay as index of organic matter were a high positive($R^2$=0.97~1.00).

  • PDF

Removal of Organic Matter and Pharmaceuticals in Wastewater Effluent through Managed Aquifer Recharge (하수처리수를 이용한 대수층 함양관리 기술(Managed Aquifer Recharge)에서 유기물과 의약화합물 제거)

  • Im, Huncheol;Yeo, Inseol;Maeng, Sung-Kyu;Choi, Heechul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.182-190
    • /
    • 2015
  • This study was conducted to evaluate the removal efficiencies of organic matter and pharmaceuticals and to identify the removal mechanism of pharmaceuticals using sand obtained from Hwangryong River in Jangsung. Batch and column studies were used to simulate managed aquifer recharge (MAR) systems. All experiments were performed using field effluent containing pharmaceuticals from Damyang Wastewater Treatment Plant as an influent. Based on the removal results of organic matter and pharmaceuticals from the batch and column experiments, soil organic matter (SOM) and microbial activity were found to effectively remove target contaminants. The removal of organic matter was found to increase under biotic conditions. Neutral and cation pharmaceuticals (iopromide, estrone, and trimethoprim) exhibited removal efficiencies higher than 70% from natural sand and baked sand media in batch and column studies. Carbamazepine persisted in the sand batch and column studies. Anion pharmaceuticals (ketoprofen, ibuprofen, and diclofenac) can be removed under conditions featuring high SOM and adenosine triphosphate (ATP) concentrations in the sand surface. Based on the experimental Batch and column results, biodegradation and sorption were found to be important mechanisms for the removal of pharmaceuticals within the simulated MAR systems.

조류를 이용한 유기성 폐수 처리 시스템과 물벼룩 성장 조건

  • Jo, Jae-Hun;Kim, Jun-Hwi;Lee, Jeong-Seop;Yun, Seong-Myeong;Kim, Si-Uk
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.568-571
    • /
    • 2001
  • Food wastewater eluted from the three-stage methane fermentation system developed in this lab showed high concentrations of TCOD, BOD, T-N and T-P. Because the effluent of biological filter chamber (BFC) still had high concentration of nitrogen and organic material, the effluent was treated with algal periphyton system using algae. The removal rates of COD, T-N and T-P wer 96, 98 and 91%, respectively, in this system. The grown algae could digested byy waterfleas using the ecological food chain system. Food wastewater is better than algal culture medium for growth of waterflea, Moima Macrocopa. During 12days, the individual of waterflea increased to 180 in the food wastewater containing a T-N concentration of 150 mg/ ${\ell}$.

  • PDF

Effect of Advanced Wastewater Treatment by Variations Operating Conditions of 4-stage Intermittently Aerated Activated Sludge process (4단 간헐포기 공정의 운전조건이 고도처리에 미치는 영향)

  • Choi, Yong-Bum;Lee, Jeong-Gyu;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.970-976
    • /
    • 2013
  • An evaluation of the organic matter removal efficiency showed high removal efficiencies of 91.1~96.3% and 91.4~97.5% for TCODcr and TBOD5, respectively, for 9hr or longer of HRT. However, the removal efficiencies decreased to 86.9~90.5% and 88.0~90.9%, respectively for 6hr of HRT. $NH_3$-N showed a high removal efficiency of 95% or higher for 9hr or longer of HRT. The total nitrogen removal efficiency was 67.6~76.7% for 9~12hr of HRT, and it decreased to 50% for 6hr of HRT, which seems to be due to the insufficient carbon source required for denitrification. The T-P removal efficiency was 32% on average. To comply with the legal standards, a chemical phosphorus removal process is needed after the reactor.

Characteristics of Pollutant Concentration from Livestock Wastewater Effluent Combined with Stormwater Runoff (강우시 및 건기시 축산지역에서 배출되는 오염물질의 유출특성 비교)

  • Tobio, Jevelyn Ann S.;Maniquiz-Redillas, Marla C.;Lee, Yuwha;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.896-901
    • /
    • 2012
  • In this research, the levels of concentrations from the junction of effluent from wastewater treatment plant during dry days and combined with runoff from the surrounding 11 ha livestock catchment area during wet days were determined to investigate the relationships of the concentration of various pollutants such as particulates, nutrients and organics originating from point and nonpoint sources. Manual sampling was conducted from October 2008 to December 2011 during dry and wet days. Based on the results, the flow rates and concentrations of most pollutant parameters were increased during wet days. It was found out that the effluent wastewater combined with stormwater runoff has low BOD to TN/TP ratio and high TN/TP to BOD ratio. Therefore, it is needed to employ other treatment methods to effectively manage the wastewater and reduce the pollutant discharge to receiving water bodies.

Effect of the supernatant reflux position and ratio on the nitrogen removal performance of anaerobic-aerobic slaughterhouse wastewater treatment process

  • Tong, Shuang;Zhao, Yan;Zhu, Ming;Wei, Jing;Zhang, Shaoxiang;Li, Shujie;Sun, Shengdan
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.309-315
    • /
    • 2020
  • Slaughterhouse wastewater (SWW) is characterized as one of the most harmful agriculture and food industrial wastewaters due to its high organic content. The emissions of SWW would cause eutrophication of surface water and pollution of groundwater. This study developed a pilot scale anaerobic-aerobic slaughterhouse wastewater treatment process (AASWWTP) to enhance the chemical oxygen demand (COD) and total nitrogen (TN) removal. The optimum supernatant reflux position and ratio for TN removal were investigated through the modified Box-Behnken design (BBD) experiments. Results showed that COD could be effectively reduced over the whole modified BBD study and the removal efficiency was all higher than 98%. The optimum reflux position and ratio were suggested to be 2 alure and 100%, respectively, where effluent TN concentration was satisfied with the forthcoming Chinese discharge standard of 25 mg/L. Anaerobic digestion and ammonia oxidation were considered as the main approaches for COD and TN removal in the AASWWTP. The results of inorganic nutrients (K+, Na+, Ca2+ and Mg2+) indicated that the SWW was suitable for biological treatment and the correspondingly processes such as AASWWTP should be widely researched and popularized. Therefore, AASWWTP is a promising technology for SWW treatment but more research is needed to further improve the operating efficiency.

Effect of the Application of Microbubbles and/or Catalyst on the Sludge Reduction and Organic matter of Livestock Wastewater (마이크로버블과 촉매 적용에 따른 가축분뇨의 슬러지와 유기오염물질 감량 효과)

  • Jang, Jae Kyung;Kim, Min Young;Sung, Je Hoon;Chang, In Seop;Kim, Tae Young;Kim, Hyun Woo;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.558-562
    • /
    • 2015
  • This study was tested to evaluate the effect of the six different combinations of microbubble, catalyst, and air as oxidant on the sludge and organic matter reduction. When all of microbubbles and catalyst, and an oxidizing agent (under Conditions 1) such as air were used, the sludge was removed more than 99%, and TCOD and SCOD removal was 58% and 13%, respectively. This result was the highest value of six conditions. In the following order, the sludge reduction of the microbubbles with air (Condition 2) and catalyst with air (condition 4) was 95% and 93.1%, respectively. TCOD removal was found to be each 53% and 47%. When the microbubbles were used with oxidant like air, the removal of sludge and organic matter was high. All of these values were higher than that of using only microbubbles and catalyst without air. In the microbubbles and catalyst react under air supply condition, OH-radicals were generated in the reaction process. These OH-radicals in the reaction process decomposed the pollutants by the strong oxidizing power. In all conditions with air, the sludge reduction was high removal rate more than 93% and TCOD removal was over 47%.

Study on Co-incineration of Municipal Solid Waste and Organic Sludges (도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구)

  • Jurng, Jong-Soo;Chin, Sung-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF