• 제목/요약/키워드: high light

검색결과 7,781건 처리시간 0.039초

White Light Emission with Quantum Dots: A Review

  • Kim, Nam Hun;Jeong, Jaehak;Chae, Heeyeop
    • Applied Science and Convergence Technology
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Quantum dots (QDs) are considered as excellent color conversion and self-emitting materials for display and lighting applications. In this article, various technologies which can be used to realize white light emission with QDs are discussed. QDs have good color purity with a narrow emission spectrum and tunable optical properties with size control capabilities. For white light emission with a color-conversion approach, QDs are combined with blue-emitting inorganic and organic light-emitting diodes (LED) to generate white emission with high energy conversion efficiency and a high color rendering index for various display and lighting applications. Various device structures for self-emitting white QD light-emitting diodes (QD-LED) are also reviewed. Various stacking and patterning technologies are discussed in relation to QD-LED devices.

천이주파수 변조를 이용한 가시광통신의 조명제어 (Illumination Control in Visible Light Communication Using Transition Frequency Modulation)

  • 이성호
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.99-104
    • /
    • 2021
  • In this study, we utilized the duty factor of the transition frequency modulation (TFM) for the illumination control of the light emitting diode (LED) light in visible light communication (VLC). The average optical power is linearly proportional to the duty factor in TFM waveforms. We used the transition frequencies of Na=5 and Nb=1 for the high and the low bits, respectively, of the non-return-to-zero (NRZ) data in the VLC transmitter. A resistor and capacitor high-pass filter (HPF) was used in the VLC receiver to eliminate the 120 Hz optical noise from adjacent lighting lamps and the spikes at the HPF output were used to recover NRZ data from the TFM waveform. In experiments, the illumination of the LED light was controlled in the range of 25-90% of the constant-wave optical power by changing the duty factor of the TFM waveforms.

Development of 3D scanner using structured light module based on variable focus lens

  • Kim, Kyu-Ha;Lee, Sang-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • 제8권3호
    • /
    • pp.260-268
    • /
    • 2020
  • Currently, it is usually a 3D scanner processing method as a laser method. However, the laser method has a disadvantage of slow scanning speed and poor precision. Although optical scanners are used as a method to compensate for these shortcomings, optical scanners are closely related to the distance and precision of the object, and have the disadvantage of being expensive. In this paper, 3D scanner using variable focus lens-based structured light module with improved measurement precision was designed to be high performance, low price, and usable in industrial fields. To this end, designed a telecentric optical system based on a variable focus lens and connected to the telecentric mechanism of the step motor and lens to adjust the focus of the variable lens. Designed a connection structure with optimized scalability of hardware circuits that configures a stepper motor to form a system with a built-in processor. In addition, by applying an algorithm that can simultaneously acquire high-resolution texture image and depth information and apply image synthesis technology and GPU-based high-speed structured light processing technology, it is also stable for changes to external light. We will designed and implemented for further improving high measurement precision.

유리도광체를 이용한 평판조명용 광확산패턴의 최적설계 연구 (Study of Optimal Light Scattering Pattern Design for Flat Lighting Device using Glass Light Guide)

  • 한정민;김원배
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.242-246
    • /
    • 2017
  • In this study, it was investigated about optical simulation in high brightness and high uniformity general lighting using glass light guide plate. And we adopt edge-light emission type light plate. Edge-light type lighting has been used LCD application, especially note PC or smart phone backlight unit. Because it had the good properties such as slim shape and light weight. We thought this type was suitable for general lighting application such as wall attached type or ceiling mount type. But many of edge-light type lighting had problems. It called slanted output light rays. That was main key parameter how could control the direction of output light rays. We investigated the solution of this problems, using ray tracing method, we recognized the major fact of the solution relied on the geometric structure of diffusing dot shape. We set the conditions of aspect ratio in diffusing dot shape such as 0.5 to 1. And, at first, we designed diffusing dots shape based on the results of optical simulation and made specimen. as above condition, and acquired good result in confirming dots shape such as the value of the output rays's peak angle was around 75 degrees. And good light distribution characteristics were measured by slated spectro-radiometer. It was shown that the effective ways of designing light distribution characteristics using optical simulation such as ray tracing linear method for making general lighting using glass light guide plate.

냉간시동시 자동차용 저온활성촉매의 성능 향상을 위한 수치적 설계 (Numerical Design of Light-off Auto-Catalyst for Reducing Cold-Start Emissions)

  • 정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1264-1276
    • /
    • 2000
  • Light-off catalyst has been used for minimization of cold-start emissions. Improved cold-start performance of light-off catalyst needs the optimal design in terms of flow distribution, geometric surface area, precious metal loading, cell density and space velocity. In this study, these influential factors are numerically investigated using integrated numerical technique by considering not only 3-D fluid flow but also heat and mass transfer with chemical reactions. The present results indicate that uneven catalyst loading of depositing high active catalyst at upstream of monolith is beneficial during warm-up period but its effect is severely deteriorated when the space velocity is above 100,000 $hr^{-1}$ To maximize light-off performance, this study suggests that 1) a light-off catalyst be designed double substrate type; 2) the substrate with high GSA and high PM loading at face be placed at the front monolith; and 3) the cell density of the rear monolith be lower to reduce the pressure drop.

LCD와 가시광선 LED를 사용한 전사방식의 Scanbeam-SLA 개발 (Development of Projection Scanbeam-SLA using Liquid Crystal Display and Visible Light Emitting Diode)

  • 윤수현;박인백;김민섭;조광호;이석희
    • 한국정밀공학회지
    • /
    • 제30권3호
    • /
    • pp.340-348
    • /
    • 2013
  • In Projection Stereolithography Apparatus (PSLA), Digital Micromirror Device (DMD) and Liquid Crystal Display (LCD) are used as a beam pattern generator. The DMD shows high resolution, but it is mostly applied in micro stereolithography due to high cost and fabricable area. In LCD, the size of pattern beam is freely controlled due to various panel sizes. The LCD, however, has some limitations such as short life time by the high power light source, non-uniform light intensity of pattern beam and low transmittance of UV-light. To solve these problems in LCD-based PSLA, a Scanbeam-SLA with LCD of 19 inches and visible LED-array is developed. In this system, the light module works like a scanner for uniform illumination. The system configuration, working principle and fabrication examples are addressed in this study.

체외 상처 치유를 위한 4-채널 광 치료기 (4-channel Light Medical Therapy Apparatus for External Injury Cure)

  • 천민우;김성환;소금영;문영래;문성표;박용필;이호식;김태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

High Cell Density Culture of Anabaena variabilis with Controlled Light Intensity and Nutrient Supply

  • Yoon, Jong-Hyun;Shin, Jong-Hwan;Ahn, Eun-Kyung;Park, Tai-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권5호
    • /
    • pp.918-925
    • /
    • 2008
  • Controlling the light energy and major nutrients is important for high cell density culture of cyanobacterial cells. The growth phase of Anabaena variabilis can be divided into an exponential growth phase and a deceleration phase. In this study, the cell growth in the deceleration phase showed a linear growth pattern. Both the period of the exponential growth phase and the average cell growth rate in the deceleration phase increased by controlling the light intensity. To control the light intensity, the specific irradiation rate was maintained above $10\;{\mu}mol/s/g$ dry cell by increasing the incident light intensity stepwise. The final cell density increased by controlling the nutrient supply. For the control of the nutrient supply, nitrate, phosphate, and sulfate were intermittently added based on the growth yield, along with the combined control of light intensity and nutrient concentration. Under these control conditions, both final cell concentration and cell productivity increased, to 8.2 g/l and 1.9 g/l/day, respectively.

마이크로컨트롤러를 이용한 창상 치유기의 특성 평가 (Analysis of Characteristic of Wound Therapy Apparatus using ${\mu}$-Controller)

  • 천민우;김성환;박용필;이호식;김태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.497-497
    • /
    • 2007
  • We developed the light medical therapy apparatus for external injury cure using a ${\mu}$-controller. This equipment was fabricated by using a high brightness LEDs and a ATmega 128, and designed to enable us to control irradiation timer, intensity and reservation. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LEDs could be controlled, stage by stage. In this paper, the designed device was used to find out how a high brightness LEDs light source affects the skin wound of a small animal. In result, compared with none light irradiation animal, the lower incidence of inflammation and faster recovery was shown in light irradiation animal.

  • PDF

의료용 4ch 광 조사 발진기 개발 (Development of 4ch Light Irradiator for Medical Therapy)

  • 천민우;김성환;문성표;박용필;김태곤;박노봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.480-480
    • /
    • 2007
  • This paper performed the basic study for developing the light therapy equipment for medical treatment. We developed the equipment for medical therapy using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled, stage by stage.

  • PDF