• 제목/요약/키워드: high frequency reconstruction

검색결과 98건 처리시간 0.03초

국내 아파트 관련 연구의 연구주제 시계열 분석 (A Study on the Time-Sectional Analysis of Apartment Housing related research in Korea)

  • 김태석;박종모;박유진;한동석
    • 대한건축학회논문집:계획계
    • /
    • 제34권3호
    • /
    • pp.45-52
    • /
    • 2018
  • Currently, apartments have become an important research subject for the overall area of politics, economics, and culture as well as urban architectural study. However, there are few analyses of the research trends related to the current interest in the apartment research and prediction of the future changes of an apartment in politics and industry. In this study, the research information related to the apartment has classified, and the changes in the research trends have analyzed. Based on the classified data, the first thesis and dissertation related to the apartment and changes of academic notation have discovered. In addition, future interests and future research directions through Frequency of Appearance, Degree Centrality Analysis, and Betweenness Centrality Analysis of author keywords were predicted. As a result of the analysis, 'Space,' 'Residential Mobility' and 'Apartment Complex' studies were found to be important research topics throughout the entire period. 'Han Gang Apartment,' 'Small Size Apartment,' 'Civic Apartments,' 'Jamsil,' and 'Child' were newly interested topics until 70's era. '(Super) High-rise Apartment,' 'Perception,' 'Jugong Apartment,' 'Housing Environment,' 'Housewife,' 'Apartment Layout,' and 'Busan' were newly interested topics during the 80's and 90's era. 'Apartment Price,' 'Energy,' 'Remodeling,' 'Noise,' 'Resident Satisfaction,' 'Community,' and 'Apartment Lotting-out' were newly interested topics after the year 2000. New concerns for last decade are found to be 'Super High-rise Apartment', 'Remodeling', 'Indoor'(2007), 'Apartment Reconstruction Project', 'Brand', 'AHP', 'Housing Environment'(2008), 'Ventilation'(2009), 'Apartment Lotting-out'(2010), 'Economic Assessment'(2011), 'Cost'(2012), 'Green Building', 'Apartment Sales', 'Law', 'Society'(2013), 'Floor Impact Noise', 'Seoul'(2014), 'Noise'(2015), 'Hedonic Model'(2016). In addition, following research topics are expected to be active in the future: In maturity stage of the research development is going to be 'Apartment Price', 'Space', 'Management of Apartment Housing'; the hedonic model, which is research growth and development stage, is going to be '(Floor Impact) Noise', 'Community', 'Energy.

디지털 임피던스 영상 시스템의 설계 및 구현 (Design and Implementation of Digital Electrical Impedance Tomography System)

  • 오동인;백상민;이재상;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.269-275
    • /
    • 2004
  • 인체내부의 각 조직은 서로 다른 저항률(resistivity)분포를 가지며, 조직의 생리학적, 기능적 변화에 따라 임피던스가 변화한다. 본 논문에서는 주로 기능적 영상을 위한 임피던스 단층촬영 (EIT, electrical impedance tomography) 시스템의 설계와 구현 결과를 기술한다. EIT 시스템은 인체의 표면에 부착한 전극을 통해 전류를 주입하고 이로 인해 유기되는 전압을 측정하여, 내부 임피던스의 단층영상을 복원하는 기술이다. EIT 시스템의 개발에 있어서는 영상복원의 난해함과 아울러 측정시스템의 낮은 정확도가 기술적인 문제가 되고 있다. 본 논문은 기존 EIT 시스템의 문제점을 파악하고 디지털 기술을 이용하여 보다 정확도가 높고 안정된 시스템을 설계 및 제작하였다. 크기와 주파수 및 파형의 변화 가능한 50KHz의 정현파 전류를 인체에 주입하기 위해 필요한 정밀 정전류원을 설계하여 제작한 결과, 출력 파형의 고조파 왜곡(THD, total harmonic distortion)이 0.0029%이고 진폭 안정도가 0.022%인 전류를 출력 할 수 있었다. 또한, 여러개의 정전류원을 사용함으로써 채 널간 오차를 유발하던 기존의 시스템을 변경하여, 하나의 전류원에서 만들어진 전류를 각 채널로 스위칭하여 공급함으로써 이로 인한 오차를 줄였다. 주입전류에 의해 유기된 전압의 정밀한 측정을 위해 높은 정밀도를 갖는 전압측정기가 필요하므로 차동증폭기, 고속 ADC및 FPGA(field programmable gate array)를 사용한 디지털 위상감응복조기 (phase-sensitive demodulator )를 제작하였다. 이때 병렬 처리를 가능하게 하여 모든 전극 채널에서 동시에 측정을 수행 할 수 있도록 하였으며, 제작된 전압측정기의 SNR(signal-to-noise ratio)은 90dB 이다. 이러한 EIT 시스템을 사용하여 배경의 전해질 용액에 비해 두 배의 저항률을 가지는 물체(바나나)에 대한 기초적인 영상복원 실험을 수행하였다. 본 시스템은 16채널로 제작되었으나 전체를 모듈형으로 설계하여 쉽게 채널의 수를 늘릴 수 있는 장점을 가지고 있어서 향후 64채널 이상의 디지털 EIT시스템을 제작할 계획이며, 인체 내부의 임피던스 분포를 3차원적 으로 영상화하는 연구를 수행 할 예정이다.

DCT-기반 영상/비디오 보안을 위한 암호화 기법 및 하드웨어 구현 (Ciphering Scheme and Hardware Implementation for MPEG-based Image/Video Security)

  • 박성호;최현준;서영호;김동욱
    • 대한전자공학회논문지SP
    • /
    • 제42권2호
    • /
    • pp.27-36
    • /
    • 2005
  • 년 논문에서는 MPEG과 JPEG, H.26X 계열 등의 DCT-기반 영상/비디오 컨텐츠에 효과적인 암호화 방법을 제안하였고, 이를 최적화된 하드웨어로 구현하여 고속동작이 가능하도록 하였다. 영상/비디오의 압축, 복원 및 암호화로 인한 많은 연산량을 고려하여 영상의 중요한 정보(DC 및 DPCM계수)만을 암호화 대상 데이터로 선정하여 부분 암호화를 수행하였다. 그 결과 암호화에 소요되는 비용은 원 영상 전체를 암호화하는 비용이 감소하였다. 여기서 Nf는 GOP내의 프레임수이고 PI는 B와 P 프레임에 존재하는 인트라 매크로블록의 수이다. 암호화 알고리즘으로는 다중모드 AES, DES, 그리고 SEED를 선택적으로 사용할 수 있도록 하였다. 제안한 암호화 방법은 C++로 구현한 소프트웨어와 TM-5를 사용하여 약 1,000개의 영상을 대상으로 실험하였다 그 결과 부분 암호화된 영상으로부터 원 영상을 추측할 수 없어 암호화 효과가 충분함을 확인하였으며, 이 때 암호화에 의한 압축률 감소율은 $1.6\%$에 불과하였다. Verilog-HDL로 구현한 하드웨어 암호화 시스템은 하이닉스 $0.25{\mu}m$ CMOS 팬텀-셀 라이브러리를 사용하여 SynopsysTM의 디자인 컴파일러로 합성함으로써 게이트-수준 회로를 구하였다. 타이밍 시뮬레이션은 CadenceTM의 Verilog-XL을 이용해서 수행한 결과 100MHz 이상의 동자 주파수에서 안정적으로 동작함을 확인하였다. 따라서 제안된 암호화 방법 및 구현된 하드웨어는 현재 중요한 문제로 대두되고 있는 종단간(end-to-end) 보안에 대한 좋은 해결책으로 유용하게 사용될 수 있으리라 기대된다.

Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method (The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method)

  • 최종숙;정우영;류재광
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.102-109
    • /
    • 2009
  • 목적 : Siemens사의 Flash 3D(Pixon(R) method, 3D OSEM)는 검사 시간을 단축하면서 재구성을 통해 영상의 질을 높일 수 있도록 개발된 소프트웨어 프로그램으로써 핵의학 단층 촬영 시 유용하게 적용되고 있는 영상처리기법이다. 그러나 감산된 영상을 Flash 3D로 재구성하여 시행하는 뇌 혈류 부하 검사 시에 영상 획득시간을 짧게 하여 검사를 시행하면 재구성된 감산 영상의 신호 대 잡음비가(SNR, signal to noise ratio) 기저 영상에 비해 낮아지는 문제점이 있었다. 감산 영상의 SNR을 높이기 위해 LEAP 검출기를 사용하였고, 뇌혈관의 해상력보다는 혈관 확장의 예민도에 더 중점을 두었다. 본 실험은 뇌혈관 부하 단층 촬영 시 LEAP 검출기의 적용 가능성을 확인하고, Flash 3D를 이용한 적정 수준의 재구성 매개 변수를 파악하는 데 목적이 있다. 실험재료 및 방법 : (1) 팬텀 평가: $^{99m}Tc$을 넣은 Hoffman 3D Brain $Phantom^{TM}$을 이용하였다. LEAP와 LEHR 검출기로 첫 번째 영상을(부하 영상에 해당) 획득하고 $^{99m}Tc$의 반감기인 6시간 후 동일한 방법으로 두 번째 영상을(기저 영상에 해당) 획득하였다. 또한, 각각의 기저 영상과 감산 영상의 SNR 및 백질과 회백질의 비를 측정하였다. (2) 환자 영상의 평가: 2008년 5월부터 2009년 1월까지 LEAP 검출기로 촬영하여 정상으로 판독된 15명과 LEHR 검출기로 촬영하여 정상으로 판독된 13명의 환자를 대상으로 영상을 정성분석 하였다. Phantom에서 얻은 재구성 매개 변수를 대입하여 평가하였다. 하루 검사 프로토콜로 시행하였으며 기저에서 925 MBq, 부하에서 925 MBq의 $^{99m}Tc$-ECD를 투여하였다. 결과 : (1) 팬텀 평가: 각 검출기에서 획득한 계수치를 측정한 결과 LEHR 기저에서는 41~46 kcount, 부하에서 79~90 kcount, 감산에서 40~47 kcount가 측정되었다. LEAP의 경우 기저에서 102~113 kcount, 부하에서 188~210 kcount, 감산에서 94~103 kcount가 측정되었다. LEHR 감산 영상의 SNR은 LEHR 기저 영상과 비교하면 37% 감소하여 나타났고, LEAP 감산 영상의 SNR은 LEAP 기저 영상과 비교하면 17% 감소하여 나타났다. 회백질과 백질의 비는 LEHR 기저에서 2.2:1 감산에서 1.9:1로 측정되었고, LEAP 기저에서는 2.4:1 감산에서 2:1로 측정되었다. (2) 환자 영상의 평가: LEHR 검출기로 획득한 계수는 기저에서 대략 40~60 kcount, 부하에서 80~100 kcount 사이였다. 기저 및 부하 영상은 FWHM을 7 mm로 (타 장비의 Cutoff에 해당), 감산 영상은 FWHM을 11 mm로 설정하는 것이 적절하였다. LEAP는 기저에서 대략 80~100 kcount, 부하에서 180~200 kcount로 측정되었다. LEAP 영상은 기저 및 부하에서 FWHM을 5 mm로, 감산에서 7 mm로 설정해야 영상의 흐림을 줄일 수 있었다. 기저 및 부하 영상은 LEHR 영상이 LEAP 영상보다 해상력이 우수했다. 그러나 감산 영상의 경우 팬텀 실험과 같이 LEHR 영상의 SNR이 떨어져 영상이 거칠게 보였다. 감산 영상은 LEAP 영상이 LEHR 영상에 비해 SNR 및 예민도가 높게 평가되었다. LEHR과 LEAP 검출기의 모든 영상에서 subset과 iteration은 8회가 적절하였다. 결론 : LEAP 검출기를 이용해 적정 수준의 필터를 사용함으로써 SNR을 높여 보다 선명한 감산 영상을 획득할 수 있게 되었다. 하루 검사 프로토콜을 적용하여 Flash 3D로 재구성하는 경우, 보다 나은 감산 영상을 얻기 위해 LEAP 검출기의 적용을 고려해 볼 수 있을 것으로 판단된다.

  • PDF

간호 관리 능력 개발을 위한 교육 연구 (Needs on Management Development Program for Head Nurse)

  • 박정선
    • 가정간호학회지
    • /
    • 제5권
    • /
    • pp.84-99
    • /
    • 1998
  • The objectives of this study are to identify the actual educational contents of management for head nurse and to propose the educational subjects according to identity the needs of head, charge, and staff nurses. The subjects were investigated the actual Management Development Programs and educational needs of head nurses and prospective nurse manager(charge nurse, staff nurse with a lot of clinical experiences) in general hospitals. The tools were composed of two questionnaires: One was developed from the literature review for making items to measure actual situation. The other was revised Katz's model for measurement of educational needs. The first respondents of actual situation were 27 general hospitals with over 400 beds in Seoul and the second respondents were 89 head nurses, 67 charge nurses and 136 nurses at 3 hospitals by convenient sampling out of 27 general hospitals. Data were collected by telephone interview, mail questionnaire and visiting from 7th of October through 30th of November in 1997. In data analysis, general characteristics of the respondents and actual status of Management Development Programs were analyzed by frequency and percentage. Educational needs according to general characteristics were analyzed by ANOVA The results were as follows: 1. Actual situation of Management Development Program 1) Seven hospitals(26%) had Management Development Program for prospective managers and 14 hospitals (52%) for head nurses. 2) Education Department existed in 14 hospitals (52%). 3) One hospital(4%) had top level managers took part in the Management Development. 4) Two hospitals selected head nurse, who had finished courses of Management Development. Eight hospitals(30%) assessed educational needs. The assessment tools consisted of making a question via questionnaire(75%), determining at department meeting(12%) and interview(13%). 5) Educational programs had 3 types: 10 lecture type, 7 discussion type and 4 role play type programs. 6) One hospital evaluated the change of learner's attitude. 7) Four hospitals scored educational point, but that was measured only by attending. 8) Actual Management Development Programs were as follows. parenthesis indicates the number of hospitals. (1) Management Development Programs for Prospective manager. Role perception of Middle level Manager (1) . Role reconstruction of Nurse Manager (1). Workshop for Charge Nurse (1). Nursing Delivery System and Nursing Process (1). Communication (1). Motivation (1) (2) Management Development Programs for Head nurse.. Head nurse's Role (5). Administrative Work (7). Service Education (4). Prevention and Countermeasure of Nursing Incidence (3). Appraisal (3) 2. The results of needs on Management Development subject 1) The educational needs of all respondents on 3 skill domains showed positive agreement to strongly positive agreement. 2) High priority(more than 4.5) items were 12 of 24 Human skill items(50%), 1 of 6 Technical skill items(16%), and 2 of 13 Conceptual skill items (15%). 3) Out of high priority items, 8 items were instituted. 4) All respondents showed high needs on 3 skill domains regardless of 3 positions (head nurse, charge nurse, and nurse). Educational needs of Human skill domain, according to position were 108. S, 108.7, 106.8 (mean score = 72) , needs of Technical skill domain were 26.5, 26.6, 26.I(mean score=18), and needs of Conceptual skill domains were 56.9,56.7, 55.1(mean score=39). 5) Needs of 3 skill domains according to clinical career showed significant difference. Out of respondents, nurses with career of over 16years showed lowest degree of needs in Human skill domains(F=4.47, P=.004) and Conceptual skill domain(F=2.93, P=.034). 6) Educational needs according to educational background were not significant difference. But out of respondents, nurses educated at 3-year junior college relatively showed lowest needs in all of the 3 skill domains. With the above-mentioned findings, further study is necessary for generalization of this study at hospitals with different bed size and location. Also it is needed to study about management skill of nurse and charge nurse, and effective educational method.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

하이브리드 비디오 코팅에 의한 디지털 홀로그램 압축기술 (Digital Hologram Compression Technique By Hybrid Video Coding)

  • 서영호;최현준;강훈종;이승현;김동욱
    • 대한전자공학회논문지SP
    • /
    • 제42권5호
    • /
    • pp.29-40
    • /
    • 2005
  • 디지털 홀로그램의 저변이 확대됨에 따라서 3차원 영상의 구성을 위한 스테레오 영상의 압축기술에 대한 국제적인 표준이 3DAV라는 형태로 진행되는 것과 같이 디지털 홀로그램의 압축 기술에 대한 논의도 활발히 이루어질 것으로 보인다. 3DAV의 경우애도 볼 수 있듯이 기존에 존재하는 여러 가지 기술들을 접목하거나 변형한 형태, 혹은 그들의 혼합된 형태로 논의될 가능성이 크다. 또한 디지털 홀로그램의 압축을 위한 전용 시스템을 구성하는 기존의 기술을 배제하고 개발하는 것은 현실적으로 어렵다. 따라서 다양한 영상압축 기술들과 디지털 홀로그램과의 상관관계에 대한 방향을 제시하고자 한다. 본 논문에서는 기존의 비디오 및 영상압축 도구들을 이용하여 디지털 홀로그램을 효율적으로 부호화하는 기술을 제안하고자 한다. Fringe 패턴의 형태로 표현되는 디지털 홀로그램의 생성 원리를 이용하여 비디오 데이터로 가공한 후에 부호화하는 방식을 이용한다. 여기에는 생성된 디지털 홀로그램을 부호화하기 위해 적절한 형태로 변형하는 전처리 과정, 객체 영상의 모든 정보를 포함하는 공간적인 분할, 디지털 홀로그램의 생성원리와 부합되는 주파수 변환기술, 비디오 데이터로 구성하기 위한 스캔방법, 부호화를 위한 주파수 계수의 분류, 그리고 하이브리드 형태의 압축기술 등이 고려되어 하나의 알고리즘을 구성한다. 압축을 위한 부호화 도구에는 정지영상 압축을 위한 JPEG2000을 비롯하여 동영상 압축을 위한 MPEG-2, MPEG-4, 및 H.264와 같은 국제 표준 압축 알고리즘들과 여러 무손실 압축 기술들이 포함된다. 실험 결과를 살펴보면 제안한 알고리즘은 기존의 기술에 비해서 4배에서 8배 이상의 높은 압축율에서 더 좋은 복원 성능을 보였다. 따라서 제안한 기술은 디지털 홀로그램의 부호화를 위한 좋은 연구 사례가 될 것으로 사료된다. 체중 부하에 의해서 생역학적인 변화를 일으키지 않고 얼마나 유지 할 수 있는지는 보다 장기적인 추시 관찰이 필요할 것으로 사료된다.이 생식소의 에너지 요구에 반응하여 변하는 것으로 추정된다.60일 후 $625{\pm}19.76{\mu}m$로 성장하였고, 생존율은 23%로 가장 높게 나타나 치패사육시 가장 적정한 수온은 $15^{\circ}C$라 판단되었다.다. 시도는 긍정적으로 평가되어야 한다. 그러므로 앞으로는 제품디자인 뿐만이 아닌 다른 다양한 분야들에게로 그 범위가 확대되어 디자인 문화적 정체성을 확립하는 연구가 뒤따라야 할 것이다.. 즉, 제품디자인의 결정요인 분석결과는 QFD의 접근방법에, 제품 디자인 파급효과 분석결과는 컨조인트 분석에 각각 보완적 기여를 할 수 있다. 이와 동시에, 실증적 분석결과는 Ettlie(1997)의 디자인 통합(DI) 이론에 대한 실증적 기반을 제공할 수 있다. 마지막으로, 성공적인 디자인 경영(DM)을 위해서는 최고 경영자의 지원뿐만 아니라 부처 간 의사소통의 장애요인을 제거하고 CFT(cross-functional team)를 운영함으로써 동시적 엔지니어링(CE) 및 제품 및 공정 디자인의 개발이 제품 개발의 속도를 가속화하고 디자인 품질을 높이며 시장 성공을 보증할 수 있도록 해야 한다.임과 채팅은 긍정적인 상호관련을 가진 것으로 나타난 반면 전자메일 서비스 이용은 성적 만족과 부정적인 상호관련을 가진 것으로 분석되었다. 이는 대학생들이 지루하게 느끼거나 외로움을 느낄 때 전자메일을 주로 이용하지만 성적 만족을 위해 전자메일을 이용하지 않고 있다는 사실을 보여주는 것이다. (3) 인터넷 이용 이후 다른 미디어와 면대면 커뮤니케이션과의 관계 인터넷을 이용한 후 응답자들의 전통적인 미디어(텔레비전, 라디오, 신문, 잡지, 편지,