The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load (고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구)

  • 임영도;김두영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.192-199
    • /
    • 2000
  • This paper describes a Phase-Shift Pulse Modulation(PSPM) and Frequency Trad이ng Pulse Modulation(FTPM) s series resonant high-frequency inverter using IGBT for the power control of high-frequency induction heating u using Neuro-Fuzzy, which is practically applied for 20kHz~500kHz induction-heating and melting power supply in i indust껴aJ fields. The adaptive frequency tracking based on the PSPM(phase-shifting pulse modulation) r regulation scherne is presented in or$\tau$ler to l11lmmlZe svvitching losses. The trially-produced breadboards using N Neuro Fuzzy controller are successfully demonstrated cUld cliscussed.

  • PDF

Development of Full-Bridge High-Frequency Resonant Inverter for Electromagnetic Induction Heating (전자유도가열용 Full-Bridge 고주파 공진형 인버터의 개발)

  • 권혁민;신대철;김용주;김기환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2943-2946
    • /
    • 2003
  • In this paper are described the indirect induction healed boiler and induction boated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20[kHz]to 50[kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

A Study on the Development of Induction Heating System for Using Full-Bridge High-Frequency Resonant Inverter (Full-Bridge 고주파 공진형 인버터를 이용한 유도가열시스템의 개발에 관한 연구)

  • Kwon H.M.;Kim S.H.;Shln D.C,;Kim Y.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.19-22
    • /
    • 2003
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 [kHz] to 50 [kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

A Study on the High-Frequency Resonant Inverter System for Indirect Induction Heating (간접유도가열용 고주파 공진형 인버터 시스템에 관한 연구)

  • Kwon H. M.;Shin D. C.;Kim K. H.;Kim Y. J.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted Into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Electromagnetic Indirect Induction Fluid Heating System using High-Frequency Inverter and Its Performance Evaluations (전압형 고주파 인버터를 이용한 간접유도가열 열유체 에너지시스템과 그 성능평가)

  • Kim, YJ;Shin, DC;Kim, KH;Uchihori, Y;Kawamura, Y
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.483-486
    • /
    • 2001
  • This Paper the state-of-the art indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter whice can operate in the frequency range from 20kHz to 50kHz. A specially-designed induction heater composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates is inserted into the ceramic type vessel with external working coil connected to the inverter and tubelence fluid through this induction heater in moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Character of Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터의 특성)

  • Mun, Sang-Pil;Kim, Chil-Ryong;Kwak, Dong-Kurl;Kim, Choon-Sam;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Soft Switching High Frequency Inverter for New Induction Heating (새로운 유도가열용 소프트 스위칭 고주파 인버터)

  • Kim, C.Y.;Mun, S.P.;Kim, M.Y.;Kim, H.J.;Lyu, J.Y.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터)

  • Mun, Sang-Pil;Gwon, Sun-Geol;Lee, Jong-Geol;Ju, Seok-Min;Gang, Sin-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

A study on the frequency control of Induction Heating System for Using Resonant Inverter (공진형 인버터을 이용한 유도가열 시스템의 주파수 제어에 관한 연구)

  • Woo, Hyoung-Gyun;Yoo, Jae-Hoon;Kwon, Hyuk-Min;Sin, Dae-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.83-85
    • /
    • 2007
  • In this paper is described frequency control of Induction Heating System for using the resonant high-frequency inverter. To follow in output temperature and frequency in order to change, it controls a system and it confirms the electric change of induction heating system.

  • PDF