• 제목/요약/키워드: high dose-rate gamma ray

Search Result 63, Processing Time 0.022 seconds

Distribution of natural radioactivity in soil and date palm-pits using high purity germanium radiation detectors and LB-alpha/beta gas-flow counter in Saudi Arabia

  • Shayeb, Mohammad Abu;Baloch, Muzahir Ali
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1282-1288
    • /
    • 2020
  • In the first study, the Radon emanation and radiological hazards associated with radionuclides in soil samples, collected from 9 various date palm farms located in 3 different districts in Saudi Arabia were determined through a high purity Germanium (HPGe) gamma-ray spectrometer. The estimated average values of Radon emanation coefficient and Radon mass exhalation rate for soil samples were 0.535 ± 0.016 and 50.063 ± 7.901 mBqkg-1h-1, respectively. The annual effective dose of radionuclides in all sampling locations was found to be lower than UNSCEAR's recommended level of 0.07 mSvy-1 for soil in an outdoor environment. In the secondary study, gross α and gross β activities in soil and date palm pits samples were measured by a low background α/β counting system. Average values of gross α and gross β activities in soil and date palm pits samples were 5.761 ± 0.360 Bqkg-1, 38.219 ± 8.619 Bqkg-1 and 0.556 ± 0.142 Bqkg-1, 24.266 ± 1.711 Bqkg-1, respectively.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Study on Measurements in Thyroid Uptake Rate Test (갑상선섭취율검사시(甲狀腺攝取率檢査時) 측정조건(測定條件)에 관(關)한 조사연구(調査硏究))

  • Kyong, Kwang-Hyon;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1981
  • This study was conducted, during the period of 20-30th, July in 1981, to survey measurement methods in thyroid uptake rate test in Seoul city. The results were summarized as follows: 1. For the great part of nuclear medcine department, a mount of radioiodine($^{131}I$) administrated to the patients was $50-100{\mu}Ci$ in thyroid uptake rate test. 2. Distribution of scintillation, counter with crystal size of $1\frac{1}{2}inch$ was 43%, 3inch(22%), 2.5inch(14%) and $2\frac{1}{2}inch$ was 7% in RAI uptake rate test. 3. When RAI uptake rate test was performed, distribution of collimator in use was flat field type collimator(78%) in general and cylindrical type collimator was 22%. 4. High voltage applied to the P-M tube was $900{\sim}1000V$(50%) and most units provided $3{\sim}15%$ of the window range for the $^{131}I$ peak $\gamma-ray$ energy. 5. Distribution on the use of neck phantom for measurements standard solution was 57% and distribution of b filter in use for room background counts and extrathyroidal tissue was 43% and 50%. 6. The distance between the counter and the source was 25cm(58%) in measuring radioactivity of standard solution, thyroid tissue and background radioactivity count. 7. The early uptake measurements(2, 4, 6 hours) are done after administration of the radioiodine dose and also 24-hour and 48-hour uptake measurements are done in routine test.

  • PDF

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

Improvement of accuracy in radioactivity assessment of medical linear accelerator through self-absorption correction in HPGe detector

  • Suah Yu;Na Hye Kwon;Sang-Rok Kim;Young Jin Won;Kum Bae Kim;Se Byeong Lee;Cheol Ha Baek;Sang Hyoun Choi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2317-2323
    • /
    • 2024
  • Medical linear accelerators with an energy of 8 MV or higher are radiated owing to photonuclear reactions and neutron capture reactions. It is necessary to quantitatively evaluate the concentration of radioactive isotopes when replacing or disposing them. HPGe detectors are commonly used to identify isotopes and measure radioactivity. However, because the detection efficiency is generally calibrated using a standard material with a density of 1.0 g/cm3, a self-absorption effect occurs if the density of the measured material is high. In this study, self-absorption correction factors were calculated for tungsten, lead, copper, and SUS-303, which are the main materials of medical linear accelerator head parts, for each gamma-ray energy using MCNP 6.2 code. The self-absorption effect was more pronounced as the energy of the emitted gamma rays decreased and the density of the measured materials increased. These correction factors were applied to the radioactivity measurements of the in-built and portable HPGe detectors. Furthermore, compared to the surface dose rate measured by the survey meter, the accuracy of the measurements of radioactivity improved by an average of 124.31 and 100.53 % for inbuilt and portable HPGe detectors, respectively. The results showed a good agreement, with an average difference of 3.70 and 5.24 %.

Multivariate statistical study on naturally occurring radioactive materials and radiation hazards in lakes around a Chinese petroleum industrial area

  • Yan Shi;Junfeng Zhao;Baiyao Ding;Yue Zhang;Zhigang Li;Mohsen M.M.Ali;Tuya Siqin;Hongtao Zhao;Yongjun Liu;Weiguo Jiang;Peng Wu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2182-2189
    • /
    • 2024
  • The high-purity germanium gamma-ray spectrometer was used to measure the radioisotope in surface water of lakes in a Chinee petroleum industrial area. 92 samples were collected from surface water of three lakes. Activity concentrations of 232Th, 226Ra and 40K in three lakes were measured, distributed in the range of 101.8-209.4, 192.1-224.9 and 335.0-548.9 mBq/L, respectively. Results were all within the limits of WHO and China. Potential environmental and health risks were assessed by calculating some radiation hazard indicators, radium equivalent index, annual effective dose, excess lifetime cancer risk, absorbed dose rate, external hazard index, internal hazard index, annual gonadal dose equivalent, activity utilization index and representative gamma index, which ranged 0.38-0.54 Bq/L, 0.06-0.08 mSv/y, 0.23 × 10-3-0.31 × 10-3, 0.17-0.24 nGy/h, 1.01 × 10-3-1.46 × 10-3, 1.55 × 10-3-2.02 × 10-3, 1.16-1.66 μSv/y, 3.13 × 10-3-4.45 × 10-3 and 2.60 × 10-3-3.77 × 10-3. The results were all at acceptable levels, meaning no impact on human health. The relationship between the electrical conductivity of surface water and the activity concentration of 232Th, 226Ra and 40K was evaluated. The electrical conductivity value was 0.241-0.369 mS/cm, showing a significant correlation coefficient between 226Ra and 40K and electrical conductivity. Multivariate statistical methods were used to determine the relationship between the activity concentrations of 232Th, 226Ra, and 40K, radiation hazard indicators and electrical conductivity.

A Study On Low Radiation Measurement of Radiation Measuring Devices and Improvement of Reaction Speed according to the Rapid Change of Radiation Dose (방사선 측정장치의 저준위 방사선 측정과 방사선량의 급격한 변화에 따른 장치의 반응 속도개선에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.544-551
    • /
    • 2014
  • This paper suggests an algorithm to measure low-level radiation by radiation measuring devices, and the other algorithm to improve reaction speed of the device to better respond to dramatic changes in radiation amount. The former algorithm to improve the accuracy of measuring low-level radiation takes advantage of a dual window radiation measurement method which is based on accumulated average of pulses gathered by a radiation measuring sensor. The latter algorithm is to enhance reaction speed of a measuring device to more sensitively react to dramatic changes in radiation amount by adopting a dual window radiation measurement method which analyzes data patterns newly put into for six seconds. To verify the suggested algorithms, a hardware-which consists of sensor and high-voltage generator, controller, charger and power supply circuit, wireless communication part, and display part-was used. Tests conducted on the dual window radiation measurement method as used in the suggested algorithm have proved that accuracy improves to measure low-level radiation of 5uSv/h, and linearity also gets better. Other tests were conducted to see whether the suggested algorithm enhances the reaction speed of a radiation measuring device so that the device responds better to dramatically changing radiation amount. The experimental results have shown meaningful changes in numbers after six seconds. Therefore, the conclusions are made that the algorithm enhances the reaction speed of the device.

Expression of Jun and p53 Genes from the Brain of Rats Irradiated with $^{60}Co{\gamma}$-ray (감마선 조사에 의한 뇌조직의 Jun 및 p53유전자 발현)

  • Kim Yong Seok;Woo Chong Kyu;Lee Yong Sung;Koh Jai Kyung;Chun Ha Chung;Lee Myung Za
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.265-279
    • /
    • 1996
  • Damage produced by radiation elicits a complex response in mammalian cells, including growth rate changes and the induction of a variety of genes associated with growth control and apoptosis. At doses of 10,000 cGy or greater, the exposed individual was killed in a matter of minutes to a couple of days, with symptoms consistent with pathology of the central nervous system(CNS) including degenerative changes. The nature of the damage in irradiated cells underlies the unique hazards of ionizing radiation. Radiation injury to CNS is a rare event in clinical medicine, but it is catastrophic for the patient in whom it occurs. The incidence of cerebral necrosis has been reported as high as 16% for doses greater than 6,000 cGy. In this study, the effect of radiation on brain tissue was studied in vivo. Jun and p53 genes in the rat brain were induced by whole body irradiation of rat with 600Co in doses between 1 Gy and 100 Gy and analyzed for expression of jun and p53 genes at the postirradiation time up to 6 hours. Northern analyses were done using 1.8 Kb & 0.8 Kb-pGEM-2-JUN/Eco RI/Pst I fragments, 2.0 Kb-php53B/Bam HI fragment and ,1.1 Kb-pBluescript SK--ACTIN/Eco RI fragment as the digoxigenin or [${\alpha}^{32}P$] dCTPlabeled probes for Jun, p53 and ${\beta}$-actin genes, respectively. Jun gene seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 1 hour after irradiation of $^{60}$Co in dose of 30 Gy. Jun was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in doses of 1 Gy and 10 Gy. After irradiation of $^{60}$Co in dose between 20 Gr and 100 Gy, the expression of Jun was however increased to peak in 2 hours and decreased thereafter. p53 gene in this study also seemed to be expressed near the threshold levels in 1 hour after irradiation of $^{60}$Co in dose less than 1 Gy and was expressed in maximum at 6 hours after irradiation of $^{60}$Co in dose of 1 Gy, p53 was expressed increasingly with time until 5 or 6 hours after irradiation of $^{60}$Co in dose between 1 Gy and 40 Gy. After irradiation of $^{60}$Co in doses of 50 Gy and 100 Gy, the expression of p53 was however increased to peak in 2 hours and decreased thereafter. The expression of Jun and p53 genes was not correlative in the brain tissue from rats. It seemed to be very important for the establishment of the optimum conditions for the animal studies relevant to the responses of genes inducible on DNA damage to ionizing radiation in mammalian cells. But there are many limitations to the animal studies such as the ununiform patterns of gene expression from the tissue because of its complex compositions. It is necessary to overcome the limitations for development of in situ Northern analysis.

  • PDF

A Monitoring Ability of the High-Performance Color CCD Camera under High Dose-Rate Gamma Ray Irradiation Environments (고 선량율 감마선 조사 환경에서의 고성능 칼라 CCD 카메라의 관측성능)

  • Cho, JaiWan;Choi, Young Soo;Seo, Yong Chil;Jeong, KyungMin
    • Annual Conference of KIPS
    • /
    • 2014.04a
    • /
    • pp.811-814
    • /
    • 2014
  • 일본 후쿠시마 제일 원자력발전소의 대지진/쓰나미에 이은 원자로 건물 수소폭발 사고의 수습 과정에서 사용후 핵연료 저장조에 보관되어 있는 핵연료의 안전문제가 대두되었다. 사용후 핵연료의 잔열 성분을 냉각시키고, 그리고 사용후 핵연료가 방출하는 고선량 방사선을 차폐시키기 위해서 일정 깊이 이상의 수조에 사용후 핵연료를 저장한다. 사용후 핵연료 저장조에 냉각수 공급이 중단되면, 사용후 핵연료의 고유 잔열에 의해 수조의 물이 증발하여 수위가 감소하게 된다. 계속해서 냉각수 공급이 되지 않으면, 사용후 핵연료의 잔열은 증가하게 되고, 수조의 물은 비등하여 증발은 가속화 된다. 사용후 핵연료 저장조의 수위가 고갈되면 고선량의 감마선이 방출된다. 수조의 수위가 정상적일 경우 사용후 핵연료 저장조의 공기중 감마선 선량율은 0.15mSv/h 이다. 수조의 수위가 사용후 핵연료 상부 꼭대기를 기준으로 2m, 1m, 및 0m (핵연료 노출) 로 감소하게 되면, 사용후 핵연료 저장조의 공기중 감마선 선량율은 500mSv/h, 50Sv/h, 및 5kSv/h 로, 급격히 증가한다. 본 논문에서는 사용후 핵연료 저장조 감시카메라의 관측 성능을 평가하기 위해, 고성능 칼라 CCD 카메라에 대해서 1 kGy/h 의 고선량율로 감마선 조사실험을 수행하였다. 이에 대한 실험결과를 기술한다.

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.