Distribution of natural radioactivity in soil and date palm-pits using high purity germanium radiation detectors and LB-alpha/beta gas-flow counter in Saudi Arabia

  • Shayeb, Mohammad Abu;Baloch, Muzahir Ali
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1282-1288
    • /
    • 2020
  • In the first study, the Radon emanation and radiological hazards associated with radionuclides in soil samples, collected from 9 various date palm farms located in 3 different districts in Saudi Arabia were determined through a high purity Germanium (HPGe) gamma-ray spectrometer. The estimated average values of Radon emanation coefficient and Radon mass exhalation rate for soil samples were 0.535 ± 0.016 and 50.063 ± 7.901 mBqkg-1h-1, respectively. The annual effective dose of radionuclides in all sampling locations was found to be lower than UNSCEAR's recommended level of 0.07 mSvy-1 for soil in an outdoor environment. In the secondary study, gross α and gross β activities in soil and date palm pits samples were measured by a low background α/β counting system. Average values of gross α and gross β activities in soil and date palm pits samples were 5.761 ± 0.360 Bqkg-1, 38.219 ± 8.619 Bqkg-1 and 0.556 ± 0.142 Bqkg-1, 24.266 ± 1.711 Bqkg-1, respectively.

An Experimental Analysis for a High Pulse Radiation Induced Latchup Conformation (고준위 펄스방사선에 의한 전자소자 Latchup의 발생시험 및 분석)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.3079-3084
    • /
    • 2014
  • When an integrated circuit device is burned out under high-intense radiation and device-level simulation that usually requires manufacturer's proprietary information is not available, experimental conformation of a failure mechanism is often the only choice. To distinguish Latchup from other causes experimentally, a new combination of multiple techniques have been developed and demonstrated. Power supply circumvention, hot-spot monitoring using an infrared camera, and supply current monitoring techniques were implemented for the conformation of the Latchup.

Pharmacological Treatment for Peptic Ulcer Bleeding (소화성 궤양 출혈의 약물 치료)

  • Ma, Dae Won;Kim, Byung-Wook
    • The Korean journal of helicobacter and upper gastrointestinal research
    • /
    • v.18 no.4
    • /
    • pp.231-234
    • /
    • 2018
  • Peptic ulcer bleeding (PUB) is the most common cause of non-variceal upper gastrointestinal bleeding, and its frequency has been declining over the past decades. However, mortality from PUB persists, and it is still a serious challenge in clinical practice. Although endoscopic intervention is the basic treatment modality for PUB, pharmacological therapy is an important adjunct. The emergence of proton pump inhibitors (PPIs) enables maintenance of intragastric pH >6, which greatly helps in the treatment of PUB. Continuous intravenous infusion of high-dose PPI reduces the re-bleeding rate, thereby helping avoid additional surgery in patients with high-risk stigmata. Moreover, administration of PPIs prior to endoscopy may reduce the need for additional endoscopic intervention. Recently introduced gastric acid suppressants, such as potassium-competitive acid blockers, have shown promising results in further treatment of PUB.

Biosorption of Cr (VI) ions by Ficus religiosa barks: Batch and continuous study

  • Karthick, S;Palani, R;Sivakumar, D;Meyyappan, N
    • Membrane and Water Treatment
    • /
    • v.13 no.5
    • /
    • pp.209-217
    • /
    • 2022
  • In the present research, Ficus religiosa Bark (FRB) is used as an adsorbent for the removal of heavy metal Cr (VI) ions. This Ficus religiosa Bark was characterized by Scanning Electron Microscope, Fourier transform infrared Spectroscopy, Thermo Gravimetric Analyzer and the results showed that activated adsorbent have high adsorption capacity and withstand even in high temperature. Batch and Continuous experiments were conducted to determine the effect of various parameters such as pH, contact time, adsorbent dose and initial metal concentration. The biosorption followed pseudo first order kinetic model. The adsorption isotherms of Cr (VI) on Ficus religiosa fitted well with the Temkin model. In Batch study, maximum biosorption capacity of Cr (VI) was found to be 37.97 mg g-1 (at optimal pH of 2, adsorbent dosage of 0.3 grams and concentration of Cr (VI) is100 mg L-1). The Continuous mode of study shows that 97% of Cr (VI) ion removal at a flow rate of 15 ml min-1. From the results, selected Ficus religiosa Bark has the higher adsorption capacity for the removal of Cr (VI) ions from wastewater.

Remote handling systems for the ISAC and ARIEL high-power fission and spallation ISOL target facilities at TRIUMF

  • Minor, Grant;Kapalka, Jason;Fisher, Chad;Paley, William;Chen, Kevin;Kinakin, Maxim;Earle, Isaac;Moss, Bevan;Bricault, Pierre;Gottberg, Alexander
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1378-1389
    • /
    • 2021
  • TRIUMF, Canada's particle accelerator centre, is constructing a new high-power ISOL (Isotope Separation On-Line) facility called ARIEL (Advanced Rare IsotopE Laboratory). Thick porous targets will be bombarded with up to 48 kW of 480 MeV protons from TRIUMF's cyclotron, or up to 100 kW of 30 MeV electrons from a new e-linac, to produce short-lived radioisotopes for a variety of applications, including nuclear astrophysics, fundamental nuclear structure and nuclear medicine. For efficient release of radioisotopes, the targets are heated to temperatures approaching 2000 ℃, and are exposed to GSv/h level radiation fields resulting from intended fissions and spallations. Due to these conditions, the operational life for each target is only about five weeks, calling for frequent remote target exchanges to limit downtime. A few days after irradiation, the targets have a residual radiation field producing a dose rate on the order of 10 Sv/h at 1 m, requiring several years of decay prior to shipment to a national disposal facility. TRIUMF is installing new remote handling infrastructure dedicated to ARIEL, including hot cells and a remote handling crane. The system design applies learnings from multiple existing facilities, including CERN-ISOLDE, GANIL-SPIRAL II as well as TRIUMF's ISAC (Isotope Separator and ACcelerator).

Evaluation of radiation resistance of an austenitic stainless steel with nanosized carbide precipitates using heavy ion irradiation at 200 dpa

  • Ji Ho Shin ;Byeong Seo Kong;Chaewon Jeong;Hyun Joon Eom;Changheui Jang;Lin Shao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.555-565
    • /
    • 2023
  • Despite many advantages as structural materials, austenitic stainless steels (SSs) have been avoided in many next generation nuclear systems due to poor void swelling resistance. In this paper, we report the results of heavy ion irradiation to the recently developed advanced radiation resistant austenitic SS (ARES-6P) with nanosized NbC precipitates. Heavy ion irradiation was performed at high temperatures (500 ℃ and 575 ℃) to the damage level of ~200 displacement per atom (dpa). The measured void swelling of ARES-6P was 2-3%, which was considerably less compared to commercial 316 SS and comparable to ferritic martensitic steels. In addition, increment of hardness measured by nano-indentation was much smaller for ARES-6P compared to 316 SS. Though some nanosized NbC precipitates were dissociated under relatively high dose rate (~5.0 × 10-4 dpa/s), sufficient number of NbC precipitates remained to act as sink sites for the point defects, resulting in such superior radiation resistance.

Effect of $Ca^{2+}$ and $Ca^{2+}-antagonists$ on the Spontaneous Contractions and Electrical Activities of Guinea-pig Stomach (기니피그 위 평활근의 자발적 수축과 전기적 활동에 대한 $Ca^{2+}$$Ca^{2+}$-길항제 영향)

  • Rhie, Sang-Ho;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.241-257
    • /
    • 1987
  • The effects of external $Ca^{2+}$ and $Ca^{2+}-antagonists$ on the spontaneous contractions and electrical activities were investigated in guinea-pig stomach in order to clarify the mechanism for the generation of slow waves. Electrical responses of circular smooth muscle cells were recorded using glass capillary microelectrodes filled with 3 M KCl. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) The amplitude of spontaneous contractions was maximal at around 2-4 mM $Ca^{2+}$, whereas their frequency was inversely related with external $Ca^{2+}$ within the range of 0.5 to 16 mM $Ca^{2+}$. 2) Verapamil suppressed the amplitude of spontaneous contraction in a dose-dependent manner, while the frequency of spontaneous contractions was almost not changed over the whole concentration of verapamil $(0.01{\sim}5\;mg/l)$. 3) Manganese increased both the amplitude and the frequency of spontaneous contractions dose-dependently in low $Mn^{2+}$ (below 0.05 mM $Mn^{2+}$), while their amplitude and frequency were decreased in high $Mn^{2+}$ (above 0.1 mM $Mn^{2+}$). 4) The ampltude and maximum rate of rise of slow waves were incrased in high $Ca^{2+}$ solution. In $Ca^{2+}-free$ solution, the spontaneous contractions recorded simultaneously with slow waves ceased and tonic contraction ($Ca^{2+}-free$ contracture) was developed in parallel with membrane depolarization and the disappearance of slow waves. 5) Verapamil (1 mg/1) decreased the amplitude and maximum rate of rise of slow waves and it depolarized the membrane by about 6 mV, whereas the frequency of slow waves was not affected by verapamil. 6) Manganese showed different characteristic effects between low and high $Mn^{2+}$ on the slow waves: In low $Mn^{2+}$ (0.05 mM $Mn^{2+}$), the initial rapid increases and the subsequent gradual decreases in three parameters of slow waves (amplitude, rate of rise, and frequency of slow waves) till a new steady state were observed. However, in high $Mn^{2+}$ (0.5 mM $Mn^{2+}$) slow waves disappeared and membrane was depolarized. From the above results, the following conclusions could be made: 1) $Ca^{2+}$ is necessary for a generation of the slow waves, even though it is small amount. 2) Verapamil suppresses the spontaneous contractions of gastric antral strip by the decreases in amplitude and maximum rate of rise of slow waves, while this drug does not block the $Ca^{2+}-channel$ involved in the generation of slow waves. 3) Manganese has dual actions on the $Ca^{2+}-channels$; the $Ca^{2+}-channel$ involved in the generation of slow waves (or Na-Ca exchange system) or the channel for the generation of spike potentials are stimulated by a low concentration of $Mn^{2+}$, while both the $Ca^{2+}$. Channels are blocked by high concentration of $Mn^{2+}$.

  • PDF

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

The Roles of Gold Plate (140${\mu}{\textrm}{m}$) Loaded on TLD-100 Chips in the High Energy Radiation Beams (고에너지 광자선속에서 TLD-100 chip 위에 있는 금박막(140 ${\mu}{\textrm}{m}$) 역할)

  • Vahc, Young-Woo;Park, Kyung Ran.
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.51-60
    • /
    • 1995
  • Lithium Fluoride (LiF; TLD-100) crystal chips are normally used as thermolu minescence dosimeters (abbreviated as NC-100) for estimating the absorbed dose to the skin of a patient or in a solid water phantom undergoing radiotherapy with megavoltage photon (6 and 15MV) beams. In general, investigation has revealed a reduction in the sensitivity of NC-100 chips after many runs through heating cycles. A TLD-100 chip laminated with gold plate (140${\mu}{\textrm}{m}$) on the upper surface layer of its face toward the photon beam (abbreviated as GC-100) has properties different from that of a NC-100 chip activated by incident photons and contaminant electrons with various lower energies coming from the gantry head and air. Activation of the valence band electrons of GC-100 chips by incident photons, positrons and electrons-which come from the gold plate by mainly pair production process and partly from Compton scattering-results in more enhanced signal intensity, higher response per monitor unit, as well as a good linearity with monitor units and independence of dose rate. Since the electron beams (6 and 15 MeV) do not have the probability of pair production process with gold plate, there is only a small difference (about a 3.3% increase for 15 MeV) in the signal gaps in the TL readout for electron beams between GC- and NC-100 chips. The 3.3% increase is entirely due to the buildup caused by the 140 m gold plate. The sensitivity of GC-100 chips is much more susceptible to high energy photon beams than electron one because of pair production. The interaction of high energy photon with a material of high atomic number, such as the good plate in this case, results in a considerably significant probability of pair production. The gold plate on the NC-100 chips acts as not only an intensifier of their signals but also acts as a filter of contaminant electrons in therapeutic high energy X-ray beams.

  • PDF

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.