• 제목/요약/키워드: high current cable

검색결과 301건 처리시간 0.029초

고속철도에 의한 통신회선 잡음전압 발생 원인 고찰 (A Study on Causes Generating Induced Noise Voltage on Telecommunications Cables Near to High-speed Rails)

  • 여상근;박찬원;김정태
    • 한국철도학회논문집
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2008
  • 본 논문은 고속철도 주변 통신회선에 발생되는 잡음전압의 실체 파악을 통해 전력유도잡음전압이 발생하지 않는 것을 증명하였으며, 국내통신회사 및 전파연구소에서 사용하고 있는 평형도 측정에서의 문제점과 계측 오류를 규명하며 표준 측정회로와 측정 조건을 ITU-T 국제 기준에 맞도록 개정할 것을 제안한다.

다중 응력 변화에 따른 에폭시 복합체의 내크랙성 및 절연 파괴 특성 (The Crack Resistance and the Dielectric Breakdown properties of Epoxy Composities due to the Multi Stresses Variation)

  • 송봉철;김상걸;안준호;김충혁;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.136-139
    • /
    • 2000
  • Epoxy materials are used as insulation material for electric power cables. In the case of a flow of excess current due to the temperature difference which occurs between the heat of the conductor and the atmosphere, heat degrades connection point of the cables. Also, the mechanical stress, which occurs due to the thermal expansion coefficient of cable connection electrode system and epoxy insulation materials along with the gap between thermal conduction based on the extra high voltage of transmitted voltage, increases possibility of cracks to occur. The relationship between mechanical stress and electrical breakdown mechanism is verified for the epoxy materials such as high toughness epoxy materials, which comes to be used contemporarily, and for the breakdown mechanism of epoxy materials on the multi-stresses (mechanical and electrical) due to the variation of the temperature.

  • PDF

Stick Type Ignition Coil Jacket PET의 접촉응력 해석 (Contact Stress Analysis of Stick Type Ignition Coil Jacket PET)

  • 김양술
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2005
  • Stick type ignition coil is new development that connect directly with ECU(Electronic control unit), without needing a spark plug cable and distributor. Glass-fiber reinforced ploymeric composites provide the desirable properties of high stiffness and strength as well as low specific weight. Stick type ignition coil jacket is using PBT CF30 resin. PBT CF30 resin is a kind of electric insulation which is a superior engineering plastic that is used to prevent the leakage of the electrical current. If PET receive a mistake of design or excessive force when HV terminal oppress on jacket, it can happen to crack. Local stress concentrations occurring on the contact surface, the contact phenomenon becomes a direct cause to the wear and failure of mechanical structures. When it is cracked, it can allow a leakage of the electrical current. So, in this study, we analyze the contact stress to PBT jacket using ANSYS program, when HV terminal oppress on jacket. We suppose PBT to be Jacket and we analyzed contact stress that happens in PET like PBT analysis method. We compared the use of PBT and PET.

The progresses of superconducting technology for power grid last decade in China

  • Xiao, Liye;Gu, Hongwei
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.1-5
    • /
    • 2015
  • With the increasing development of renewable energy, it is expected that large-scale renewable power would be transported from the west and north area of China to the east and south area. For this reason, it will be necessary to develop a wide-area power grid in which the renewable energy would be the dominant power source, and the power grid will be faced by some critical challenges such as long-distance large-capacity power transmission, the stability of the wide-area power grid and the land use problem for the power grid. The superconducting technology for power (STP) would be a possible alternative for the development of China's future power grid. In last decade, STP has been extensively developed in China. In this paper, we present an overview of the R&D of STP last decade in China including: 1) the development of high temperature superconducting (HTS) materials, 2) DC power cables, 3) superconducting power substations, 4) fault current limiters and 5) superconducting magnetic energy storage (SMES).

운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구 (A Study on the Deterioration Process of 22kV Power Cables in Operation)

  • 이관우;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.127-133
    • /
    • 2013
  • 산업사회의 발전에 필수적인 요소 중의 하나로서, 전력 에너지의 수요는 과학 기술의 발전에 따라 꾸준히 증가해오고 있다. 전력의 수요에 부응하기 위해, 고전압과 대용량을 감당할 전력설비기 필요하다. 튼튼한 바탕 위에서 전력을 생산 공급하기 위해서는 전기 시설은 신뢰성 있게 운전해야 한다. 전력 설비가 사고를 일으킬 경우 막대한 국가적 손실을 초래하게 된다. 국가 기간 산업 시설의 중추적인 기능을 하고 있는 전력 설비는 가능한 안정된 상태를 유지하면서 오랜 기간 동안 운전할 수 있어야 하며, 사고를 미리 예방할 수 있어야 한다. 전력을 전달하기 위한 수단으로서 사용되고 있는 케이블 설계 시 수명을 약 30년으로 간주하지만, 많은 경우의 실제 현장에서는 8~12년 정도에서 파괴 현상이 발생하여 재산상의 큰 피해를 초래한다. 본 논문은 운전 중 22kV 케이블 시스템의 열화 과정에 대한 연구를 통하여 열화의 원인을 파악하였으며, 와이블 분포만 따르는 것이 아니라 열열화 후 와이블 열화를 거쳐 부분 방전에 의하여 케이블이 파괴되는 것을 확인 할 수 있었다.

적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정 (Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry)

  • 박명진;임형우;이광연;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

$M_1-P-M_2$형 접촉으로 인하여 생기는 단락전류 (Short-Circuit Currents arising at a $M_1-P-M_2$ Contacts)

  • 이덕출
    • 전기의세계
    • /
    • 제25권1호
    • /
    • pp.95-100
    • /
    • 1976
  • The main purpose of this paper is to study on the transient current due to the change of environmental temperature under no external field in the arrangement of M$_{1}$(metal)-P(polyver)-M$_{2}$(metal). The specimer of polymeric insulator sandwiched by two metal electrodes composes a parallel-plate condenser represented by Maxwell-model. The behaviors of short circuit current flowing in M-P-M arrangement are very complex and the analysis of its conduction mechanism appears to be much complicated. In this paper we can suggest that a contact potential difference as an energetic state exists in the thin film specimen both sides of which are contacted by two different metals having different cook functions. Futhermore the contact potential difference appears to be constant through the course of temperature change, however, the dielectric constant and caparitance of the specimen must be temperature dependent. Accordingly the charge difference induced on both sides of electrodes may be a cause for the shory circuited transient current flowing through the external circuit. It is also suggestive that the results of the observation must be considered in cases of insulation design of electrical machines and D.C. cable for high voltage use.

  • PDF

고압폐쇄분전반의 전력케이블 헤드와 안전셔터에서의 사고위험 평가 (Accident Risk Assessment between Power Cable Head and Safety Shutter in Medium Voltage Metal-Clad Switchgear)

  • 송길목;한운기;김영석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.264-267
    • /
    • 2006
  • This paper describes the accident analysis by modeling the current transformer mounting in meaium voltage metal-clad switchgear(MCSG). In analyzing the accident the reconstruction at the current transformer mounting(VCB connecting guide) has to be taken into account. The accident was modelled as a 3-phase ground fault mounting between the end plate of a high voltage lines and the safety shutter at the current transformer mounting of the VCB inside the metal clad switchgear. Since the outside maintenance of the metal clad switchgear is restricted by the enclosed compartments, its circumference has to be kept clean. Through the reconstruction results, it was confirmed that the fault of the enclosed switchboard could be reduced when the shutter made of Fe material was changed into an insulation.

  • PDF

Fabrication and Test of Multiple HTS Wire with Transposition for HTS Power Transformer

  • Kim, Woo-Seok;Park, Chan;Choi, Kyeong-Dal
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.34-37
    • /
    • 2008
  • According to the recent design of an HTS (High Temperature Superconducting) power transformer whose capacity is hundreds MVA, the rated current values of the low voltage side are generally over thousands amps. Considering the performance of the recent HTS wires, it is inevitable to use several HTS wires in parallel for large rated current. Lots of stacked HTS wires were fabricated and tested so far, and the results have showed that we have to transpose each wire in order to reduce the AC losses as well as to increase the current capacity. But many development programs about HTS transformers reveal that the transposition of the several wires during the winding process is quite difficult not only in case of the layer windings but also in case of the pancake type ones. So, we need transposed multiple HTS wire which we can handle like single wire or cable for the HTS windings of large capacity power transformer. We fabricated several kinds of samples of multiple HTS wire with transposition to apply it to the HTS windings of power transformer. The electrical characteristics such as critical currents or AC losses are analyzed by experiments in case by case. Finally we present the best design of a multiple HTS wire for power transformer.

YBCO 2G 선재간 접합 특성 연구 (Charateristics analysis of the joining of YBCO 2G HTS wire)

  • 장기성;박동근;양성은;안민철;조대호;김현규;;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.741-742
    • /
    • 2006
  • This paper deals with an efficient superconducting joint method between 2G high superconducting(HTS) wire, YBCO coated conductor(CC). Recently CC is one of the most promising superconducting wire due to high n-value and critical current independency from external magnetic field. It is expected to be used many superconducting application such as fault current limiter, persistent current system and cable etc. In most HTS applications, superconducting magnet is used, and it is necessary to joint between superconducting wire to fabricate superconducting magnet system. A CC tape used in this research consists of copper stabilizer, silver layer, YBCO layer, buffer and substrate. Direct joint using soldering method was inefficient due to resistance of copper, then copper lamination is removed by chemical etching method to reduce resistance between CC tapes. Jointed tapes were fabricated and tested. Transport current through jointed area and induced voltage were measured to characterize the I-V curve. Resistance between CC wire using chemical etching was compared with resistance of direct jointed tapes using soldering method in this paper.

  • PDF