• Title/Summary/Keyword: high breakdown point

Search Result 72, Processing Time 0.028 seconds

Algorithm for the L1-Regression Estimation with High Breakdown Point (L1-회귀추정량의 붕괴점 향상을 위한 알고리즘)

  • Kim, Bu-Yong
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.4
    • /
    • pp.541-550
    • /
    • 2010
  • The $L_1$-regression estimator is susceptible to the leverage points, even though it is highly robust to the vertical outliers. This article is concerned with the improvement of robustness of the $L_1$-estimator. To improve its robustness, in terms of the breakdown point, we attempt to dampen the influence of the leverage points by means of reducing the weights corresponding to the leverage points. In addition the algorithm employs the linear scaling transformation technique, for higher computational efficiency with the large data sets, to solve the linear programming problem of $L_1$-estimation. Monte Carlo simulation results indicate that the proposed algorithm yields $L_1$-estimates which are robust to the leverage points as well as the vertical outliers.

Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System (지중송전 편단접지개소에서의 병행지선 설치효과 검토)

  • Kang, J.W.;Park, H.S.;Yoon, H.H.;Yoon, J.K.;Bae, J.H.;Suk, K.H.;Oh, J.M.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF

Dielectric Strength of $SF_6/CF_4$ Mixture Under Standard Lightning Impulse Voltages in Non-Uniform Field (불평등 전계에서 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스의 절연 내력)

  • Huh, Chang-Su;Sung, Heo-Gyung;Park, Shin-Woo;Hwang, Cheong-Ho;Kim, Nam-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.165-166
    • /
    • 2007
  • In these days $SF_6$ mixtures and alternative gas have been studied because of global warming and liquefying at low temperature and high pressure. At present work the breakdown characteristics of $SF_6/CF_4$ mixture in non-uniform field was performed. The experiments were carried out under positive and negative standard lightning impulse (SLT) voltages. The point-plane electrode was used with 3 mm gap distance in the test chamber. The $SF_6/CF_4$ mixture which contain 20% of $SF_6$ was compared with pure $SF_6$ and $CF_4$ gas. Experimental gas pressure ranged from 0.1 to 0.4 MPa. The breakdown voltage under negative SLI is higher than the breakdown voltage under positive voltage. And the breakdown voltage of $SF_6$ 20%, $CF_4$ 80% mixture is similar to that of pure $SF_6$.

  • PDF

Study on Latch Up Characteristics of Super Junction MOSFET According to Trench Etch Angle (Trench 식각각도에 따른 Super Juction MOSFET의 래치 업 특성에 관한 연구)

  • Chung, Hun Suk;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.551-554
    • /
    • 2014
  • This paper was showed latch up characteristics of super junction power MOSFET by parasitic thyristor according to trench etch angle. As a result of research, if trench etch angle of super junction MOSFET is larger, we obtained large latch up voltage. When trench etch angle was $90^{\circ}$, latch up voltage was more 50 V. and we got 700 V breakdown voltage. But we analyzed on resistance. if trench etch angle of super junction MOSFET is larger, we obtained high on resistance. Therefore, we need optimal point by simulation and experiment for solution of trade off.

A Study on the Electrical and Mechanical Properties of Conduction Cooling HTS SMES

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Shin, H.S.;Kim, H.J.;Seong, K.C.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.29-32
    • /
    • 2009
  • The conduction cooling HTS SMES magnet is operated in cryogenic temperature. The insulation design at cryogenic temperature is an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction cooling HTS SMES. Specially, this paper was studied about high vacuum and cryogenic temperature breakdown and flashover discharge characteristics between cryocooler and magnet-coil. The breakdown and surface flashover discharge characteristics were experimented at cryogenic temperature and vacuum. Also, we were experimented about mechanical properties of 4-point bending test. From the results, we confirmed that about research between cryocooler and magnet-coil established basic data in the insulation design.

Self-tuning Robust Regression Estimation

  • Park, You-Sung;Lee, Dong-Hee
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2003.10a
    • /
    • pp.257-262
    • /
    • 2003
  • We introduce a new robust regression estimator, self-tuning regression estimator. Various robust estimators have been developed with discovery for theories and applications since Huber introduced M-estimator at 1960's. We start by announcing various robust estimators and their properties, including their advantages and disadvantages, and furthermore, new estimator overcomes drawbacks of other robust regression estimators, such as ineffective computation on preserving robustness properties.

  • PDF

Influence of the C.T.I of phenolic resin (페놀수지의 C.T.I에 미치는 영향)

  • 이보호;박동화;정인성
    • Electrical & Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.70-77
    • /
    • 1988
  • This paper describes the influence of the electrode materials, moisture content, electrolyte density, temperature, surface state, ion absorbent on the C.T.I of phenolic resin by the I.E,C, 112 method. C.T.I are increased for electrode materials with low hydrogen overvoltage and high soluble point. Increusing moisture content of samples increased by logarithmical on the droplet number to tracking breakdown. Increasing electrolyte temperature region above 70-80(.deg.C) decreased hydrogen over-voltage, following the density changes are decreased by C.T.I=1/aD$^{2}$-bD+C.

  • PDF

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

A comparison study of various robust regression estimators using simulation (시뮬레이션을 통한 다양한 로버스트 회귀추정량의 비교 연구)

  • Jang, Soohee;Yoon, Jungyeon;Chun, Heuiju
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.3
    • /
    • pp.471-485
    • /
    • 2016
  • Least squares (LS) regression is a classic method for regression that is optimal under assumptions of regression and usual observations. However, the presence of unusual data in the LS method leads to seriously distorted estimates. Therefore, various robust estimation methods are proposed to circumvent the limitations of traditional LS regression. Among these, there are M-estimators based on maximum likelihood estimation (MLE), L-estimators based on linear combinations of order statistics and R-estimators based on a linear combinations of the ordered residuals. In this paper, robust regression estimators with high breakdown point and/or with high efficiency are compared under several simulated situations. The paper analyses and compares distributions of estimates as well as relative efficiencies calculated from mean squared errors (MSE) in the simulation study. We conclude that MM-estimators or GR-estimators are a good choice for the real data application.