• Title/Summary/Keyword: high bone

Search Result 1,722, Processing Time 0.029 seconds

A HISTOLOGIC COMPARATIVE STUDY OF LOADED AND UNLOADED TITANIUM IMPLANTS (LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구)

  • Kim, Yung-Soo;Ko, Jea-Seung;Hwang, Sung-Myung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.1-16
    • /
    • 1991
  • In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.

  • PDF

Clinical Study on the Alveolar Bone Repair Capacity of Dentin Matrix Block (Dentin Matrix Block의 치조골 복원 능력에 관한 임상적 연구)

  • Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • In the oral and maxillofacial area, bone defects are created by various reasons and demand for bone grafts, while dental implant implantation has been increased consistently. To solve these problems, there has been development of autogenous tooth-bone graft material (AutoBT$^{(R)}$, Korea Tooth Bank Co., Korea), and we have collected ground reasons to substitute free autobone graft with this material in clinical use. This autogenous tooth-bone graft material is produced in powder type and block type. Block type is useful in esthetic reconstruction of the defect site and vertical and horizontal augmentation of alveolar bone because this type has high strength value, well maintained shape and is less absorbed. Therefore, the author of this study gained favorable result by grafting the block type autogenous tooth-bone graft material after dental implant implantation on the bone defects of the mandibular molar extraction site. Moreover, the author represents this case with literature review after confirming bone remodeling on the computed tomography image and by histological analysis.

A Finite Element Analysis of Stress on the Femoral Stem with Resorption of Proximal Medial Femur after Total Hip Replacement (대퇴골 근위부 골흡수가 인공 고관절 대퇴 stem에 미치는 응력에 관한 연구-FEM을 이용한 분석)

  • 김성곤
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.183-188
    • /
    • 1994
  • In clinical orthopaedics, bone resoption in the cortex is often seen post operatively on X-rays or bone densitometry after total hip replacement (THR) in the form of cortical osteoporosis or atropy. Stress shielding of bone occurs, when a load, normally carried by the bone alone, is shared with an implant as a result, the bone stresses are abnormal and with remodelling analysis this may cause extensive proximal bone resoption, possibly weakening the bone bed to the point of failure. The author made finite element models of the cemented and non-cemented type implanted femoral stem with bone resorption of the proximal medial femur and studied the feed back effect of the various degree of bone resoption to THR system by parametric analysis on the stress of the femoral stem and interface. The results of the present finite element analysis implied that the extent of proximal bone resorption has the effect of more increasing stress on the distal stem tip, cement mantle and interface in both type of femoral stem and this high distal stress possibly can cause the mechanical failure of loosening or failure after THR.

  • PDF

Limb-Salvage Surgery using Ilizarov Technique - Report of 2 cases - (Ilizarov술식을 이용한 사지 구제술 - 2례 보고 -)

  • Cho, Duck-Yun;Koh, Eun-Sung;Lee, Ji-Sup
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.226-232
    • /
    • 1995
  • Survival rate of osteosarcoma has been improved recently due to the neoadjuvant and adjuvant chemotherapy. Limb-salvaging operation(LSO) has replaced the amputation technique without' lowering the survival rate. And there occurred a lot of patients who are suffering from the high cost of artificial implants and forced to choose amputation due to economic problem. In LSO, usually relatively high cost artifical implant is needed. When a patient and not afford such an expensive implant he had to choose an inexpensive way, amputation. Authors tried bone lengthening by adopting Ilizarov technique after wide resection of tumor in two patients. Bone transportation was successful in one patient and less successful in the other. One case in CDF(continuosly disease free since the surgical procedure) state at follow-up 3 year 4 months after knee joint fusion. And the other was given lobectomy for lung metastasis at postop. 1 year and 9 months, and given osteosynthesis for infected nonunion at the docking site. Bone transportation was thought to be a good method for the bony coverage of dead space caused by wide resection. Bone transportation technique was economical as well as biological We present two osteosarcoma patient who treated with Ilizarov bone transportation.

  • PDF

Bone Metastasis from Gastric Cancer: The Incidence, Clinicopathological Features, and Influence on Survival

  • Turkoz, Fatma Paksoy;Solak, Mustafa;Kilickap, Saadettin;Ulas, Arife;Esbah, Onur;Oksuzoglu, Berna;Yalcin, Suayib
    • Journal of Gastric Cancer
    • /
    • v.14 no.3
    • /
    • pp.164-172
    • /
    • 2014
  • Purpose: To evaluate the incidence, clinicopathological characteristics, treatment outcomes, prognostic factors, and survival of gastric cancer patients with bone metastases. Materials and Methods: Of 4,617 gastric cancer patients who were treated between 2001 and 2013, 176 patients with bone metastases were analyzed. Results: The incidence of bone metastasis was 3.8%. The most common histopathological subtype was adenocarcinoma (79%) with poor differentiation (60.8%). The median interval from the diagnosis to bone metastasis was 11 months. The median survival time after bone metastasis was 5.4 months. Factors that were associated with longer median survival times included the following: isolated bone metastasis (P=0.004), well-differentiated tumors (P=0.002), palliative chemotherapy (P=0.003), zoledronic acid treatment (P<0.001), no smoking history (P=0.007), and no metastatic gastric cancer at the time of diagnosis (P=0.01). On the other hand, high levels of lactate dehydrogenase (LDH) (hazard ratio [HR]: 1.86; P=0.015), carcinoembryonic antigen (CEA) (HR: 2.04; P=0.002), and carbohydrate antigen (CA) 19-9 (HR: 2.94; P<0.001) were associated with shorter survival times. In multivariate analysis, receiving zoledronic acid (P<0.001) and performance status (P=0.013) were independent prognostic factors. Conclusions: Smoking history, poor performance status, poorly differentiated adenocarcinoma, and high levels of LDH, CEA, and CA 19-9 were shown to be poor prognostic factors, while receiving chemotherapy and zoledronic acid were associated with prolonged survival in gastric cancer patients with bone metastases.

A Comparative Study of Quantitative Assessment of Bone Mineral Density of the Mandible (하악골 골염도의 정량적 평가에 관한 비교연구)

  • Park Won-Kyl;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.161-173
    • /
    • 1999
  • This study was performed to compare the bone mineral densities measured at mandibular premolar area by copper-equivalent image and hydroxyapatite phantom with those measured at radius by dual energy absorptiometry and to evaluate the clinical usefulness of Digital system with slide scanner, copper-equivalent image, and hydroxyapatite phantom. For experiment. intraoral radiograms of 15 normal subjects ranged from 20 years old to 67 old were taken with copper-step wedge at mandibular premolar area and bone mineral densities calculated by conversion equation to bone mineral density of hydroxyapatite were compared with those measured at radius distal 1/3 area by Hologic QDR-1000. Obtained results as follows: 1) The conversion equation was Y=5.97X-0.25 and its determination coefficient was 0.9967. The coefficient of variation in the measurement of copper-equivalent value ranged from 4% to 8% and showed high reproducibility. 2) The coefficient of variation in the measurement of bone mineral density by the equation ranged from 7% to 8% and showed high reproducibility. 3) The bone mineral densities ranged from 0.35 to 0.79g/cm2 at mandibular premolararea. 4) The correlation coefficient between bone mineral densities at mandibular premolar area and those at radius distal 1/3 area was 0.8965. As summary, digital image analyzing system using copper-equivalent image and hydroxyapatite phantom appeared to be clinically useful to measure the bone mineral density at dental area.

  • PDF

Treatment concepts for the posterior maxilla and mandible: short implants versus long implants in augmented bone

  • Thoma, Daniel Stefan;Cha, Jae-Kook;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.2-12
    • /
    • 2017
  • The aim of this narrative review is to describe treatment options for the posterior regions of the mandible and the maxilla, comparing short implants vs. longer implants in an augmented bone. The dental literature was screened for treatment options enabling the placement of dental implants in posterior sites with a reduced vertical bone height in the maxilla and the mandible. Short dental implants have been increasingly used recently, providing a number of advantages including reduced patient morbidity, shorter treatment time, and lower costs. In the posterior maxilla, sinus elevation procedures were for long considered to be the gold standard using various bone substitute materials and rendering high implant survival rates. More recently, implants were even placed without any further use of bone substitute materials, but the long-term outcomes have yet to be documented. Vertical bone augmentation procedures in the mandible require a relatively high level of surgical skill and allow the placement of standard-length dental implants by the use of autogenous bone blocks. Both treatment options, short dental implants, and standard-length implants in combination with vertical bone augmentation procedures, appear to result in predictable outcomes in terms of implant survival rates. According to recent clinical studies comparing the therapeutic options of short implants vs. long implants in augmented bone, the use of short dental implants leads to a number of advantages for the patients and the clinician.

Bone Regeneration Using Block-type Deproteinized Porcine Bone Mineral with Collagen Membrane Using 3,4-Dihydroxyphenylalanine as Bone Adhesive

  • Kang, Joo Hyun;Pae, Hyoung-Chul;Cha, Jae-Kook;Lee, Jung-Seok;Paik, Jeong-Won;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Korean Dental Science
    • /
    • v.11 no.2
    • /
    • pp.43-56
    • /
    • 2018
  • Purpose: The purpose of this study was to assess the adhesiveness and cytotoxicity of 3, 4-dihydroxyphenylalanine (DOPA), and to evaluate the role of collagen membrane with DOPA in the guided bone regeneration. Materials and Methods: Peel resistance and cell cytotoxicity test were performed. Four defect types in nine rabbit calvaria were randomly allocated: i) control, ii) membrane, iii) deproteinized porcine bone mineral (DPBM) covered by membrane with DOPA, and iv) DPBM covered by membrane with cyanoacrylate. Animals were sacrificed at 2 (n=4) and 8 weeks (n=5) for microcomputed tomography and histomorphometric analysis. DOPA showed low peel resistance but high cell viability. Result: Cyanoacrylate and DOPA groups showed significantly higher mineralized tissue volume (MTV) compared to control and membrane groups at 2 weeks (P<0.05). At 8 weeks, DOPA group showed the highest MTV. Significantly higher new bone area was found in DOPA group at 8 weeks (P<0.05). Bone formation increased from 2 to 8 weeks in DOPA group (P<0.05). Conclusion: DOPA showed high cell viability and in vivo study revealed predictable performance in bone regeneration.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.