• Title/Summary/Keyword: high accuracy

Search Result 8,794, Processing Time 0.05 seconds

A New Method For Measuring Acupoint Pigmentation After Cupping Using Cross Polarization (교차편광 촬영술(Cross Polarization Photographic Technique)를 이용한 부항요법의 배수혈 피부 색소 침착 변화 측정 평가)

  • Kim, Soo-Byeong;Jung, Byungjo;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.252-263
    • /
    • 2013
  • Objectives : Skin color deformation by cupping has been widely used as a diagnostic parameter in Traditional Korean Medicine(TKM). Skin color deformation such as ecchymoses and purpura is induced by local vacuum in a suction cup. Since existing studies have relied on a visual diagnostic method, there is a need to use the quantitative measurement method. Methods : We conducted an analysis of cross-polarization photographic images to assess the changes in skin color deformation. The skin color variation was analyzed using $L^*a^*b^*$ space and the skin erythema index(E.I.). The meridian theory in TKM indicates that the condition of primary internal organs is closely related to the skin color deformation at special acupoints. Before conducting these studies, it is necessary to evaluate whether or not skin color deformation is influenced by muscle condition. Hence, we applied cupping at BL13, BL15, BL18, BL20 and BL23 at Bladder Meridian(BL) and measured blood lactate at every acupoint. Results : We confirmed the high system measurement accuracy, and observed the diverse skin color deformations. Moreover, we confirmed that the $L^*$, $a^*$ and E.I. had not changed after 40 minutes(p>0.05). The distribution of blood lactate levels at each part was observed differently. Blood lactate level and skin color deformation at each part was independent of each other. Conclusions : The negative pressure produced by the suction cup induces a reduction in the volumetric fraction of melanosomes and subsequent reduction in epidermal thickness. The relationship between variations of tissue and skin properties and skin color deformation degree must be investigated prior to considering the relationship between internal organ dysfunction and skin color deformation.

Vitamin C Quantification of Korean Momordica charantia by Cultivar, Harvest Time, and Maturity (국내산 여주의 지역별, 수확시기별, 숙기별 Vitamin C 함량)

  • Jeong, Yun Sook;Lee, Sang Hoon;Song, Jin;Hwang, Kyung-A;Noh, Geon Min;Hwang, In Guk
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • This study aimed to investigate the concentration of vitamin C in Momordica charantia (MC) by cultivar, harvest time, and maturity. The methods for determining vitamin C levels were validated by measuring their linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy using HPLC. Results showed high linearity in the calibration curve, with a coefficient of correlation ($R^2$) of 0.9994. The LOD and LOQ values for vitamin C were 0.05 and $0.16{\mu}g/mL$, respectively. The relative standard deviations (RSDs) for intra- and inter-day precision of vitamin C measurements were 2.34 and 1.34%, respectively. Depending on cultivar, the concentration of vitamin C in MC varied from 20.75~107.31 mg/100 g, fresh weight, with an average level $68.85{\pm}25.57mg/100g$, FW. When MC was analyzed by harvest time, the 20150612 MC showed the highest amount of vitamin C ($113.20{\pm}1.89mg/100g$, FW). On the other hand, the highest vitamin C content by maturity was $48.59{\pm}0.87mg/100g$, FW (15 day old MC). This information on the comparative vitamin C levels of MC might be useful to food scientists and should be explored for functional food development.

The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition (PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화)

  • Hong, Gun-Chul;Park, Sun-Myung;Kwak, In-Suk;Lee, Hyuk;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Purpose: Partial volume effect (PVE) is the phenomenon to lower the accuracy of image due to low estimate, which is to occur from PET/CT 3D image acquisition. The more resolution is declined and the lesion is small, the more it causes a big error. So that it can influence the test result. Studied the optimum image reconstruction method by using variation of parameter, which can influence the PVE. Materials and Methods: It acquires the image in each size spheres which is injected $^{18}F$-FDG to hot site and background in the ratio 4:1 for 10 minutes by using NEMA 2001 IEC phantom in GE Discovey STE 16. The iterative reconstruction is used and gives variety to iteration 2-50 times, subset number 1-56. The analysis's fixed region of interest in detail part of image and compute % difference and signal to noise ratio (SNR) using $SUV_{max}$. Results: It's measured that $SUV_{max}$ of 10 mm spheres, which is changed subset number to 2, 5, 8, 20, 56 in fixed iteration to times, SNR is indicated 0.19, 0.30, 0.40, 0.48, 0.45. As well as each sphere's of total SNR is measured 2.73, 3.38, 3.64, 3.63, 3.38. Conclusion: In iteration 6th to 20th, it indicates similar value in % difference and SNR ($3.47{\pm}0.09$). Over 20th, it increases the phenomenon, which is placed low value on $SUV_{max}$ through the influence of noise. In addition, the identical iteration, it indicates that SNR is high value in 8th to 20th in variation of subset number. Therefore, to reduce partial volume effect of small lesion, it can be declined the partial volume effect in iteration 6 times, subset number 8~20 times, considering reconstruction time.

  • PDF

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Simulation Approach for the Tracing the Marine Pollution Using Multi-Remote Sensing Data (다중 원격탐사 자료를 활용한 해양 오염 추적 모의 실험 방안에 대한 연구)

  • Kim, Keunyong;Kim, Euihyun;Choi, Jun Myoung;Shin, Jisun;Kim, Wonkook;Lee, Kwang-Jae;Son, Young Baek;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_2
    • /
    • pp.249-261
    • /
    • 2020
  • Coastal monitoring using multiple platforms/sensors is a very important tools for accurately understanding the changes in offshore marine environment and disaster with high temporal and spatial resolutions. However, integrated observation studies using multiple platforms and sensors are insufficient, and none of them have been evaluated for efficiency and limitation of convergence. In this study, we aimed to suggest an integrated observation method with multi-remote sensing platform and sensors, and to diagnose the utility and limitation. Integrated in situ surveys were conducted using Rhodamine WT fluorescent dye to simulate various marine disasters. In September 2019, the distribution and movement of RWT dye patches were detected using satellite (Kompsat-2/3/3A, Landsat-8 OLI, Sentinel-3 OLCI and GOCI), unmanned aircraft (Mavic 2 pro and Inspire 2), and manned aircraft platforms after injecting fluorescent dye into the waters of the South Sea-Yeosu Sea. The initial patch size of the RWT dye was 2,600 ㎡ and spread to 62,000 ㎡ about 138 minutes later. The RWT patches gradually moved southwestward from the point where they were first released,similar to the pattern of tidal current flowing southwest as the tides gradually decreased. Unmanned Aerial Vehicles (UAVs) image showed highest resolution in terms of spatial and time resolution, but the coverage area was the narrowest. In the case of satellite images, the coverage area was wide, but there were some limitations compared to other platforms in terms of operability due to the long cycle of revisiting. For Sentinel-3 OLCI and GOCI, the spectral resolution and signal-to-noise ratio (SNR) were the highest, but small fluorescent dye detection was limited in terms of spatial resolution. In the case of hyperspectral sensor mounted on manned aircraft, the spectral resolution was the highest, but this was also somewhat limited in terms of operability. From this simulation approach, multi-platform integrated observation was able to confirm that time,space and spectral resolution could be significantly improved. In the future, if this study results are linked to coastal numerical models, it will be possible to predict the transport and diffusion of contaminants, and it is expected that it can contribute to improving model accuracy by using them as input and verification data of the numerical models.

Vitamin C Quantification of Korean Sweet Potatoes by Cultivar and Cooking Method (국내산 고구마의 품종 및 조리방법별 비타민 C 함량)

  • Hwang, In Guk;Byun, Jae Yoon;Kim, Kyung Mi;Chung, Mi Nam;Yoo, Seon Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.955-961
    • /
    • 2014
  • This study was carried out to investigate the amounts of vitamin C in 22 sweet potato cultivars cultivated in Korea as well as evaluate the effects of cooking methods on vitamin C contents. Methods for determining vitamin C was validated by determining linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy using HPLC. Results showed high linearity in the calibration curve with a coefficient of correlation ($R^2$) of 0.9999. The LOD and LOQ values for ascorbic acid (AA) were 0.03 and $0.10{\mu}g/mL$, respectively. The relative standard deviations (RSDs) for intra- and inter-day precision of AA were less than 5%. The recovery rates of AA and dehydroascorbic acid (DHA) were in the range from 98.21~98.64 and 98.28~100.68%, respectively. Depending on cultivar, contents of AA, DHA, and total ascorbic acid (TA) in sweet potatoes varied in the range from 37.76 (Sinyulmi)~89.25 (Juhwangmin), 23.37 (Sinjami)~63.94 (Sinyulmi), and 68.52 (Sinjami)~115.95 (Juhwangmin) mg/100 g, respectively, and their average levels were $56.98{\pm}12.53$, $36.46{\pm}9.03$, and $93.44{\pm}12.00mg/100g$, respectively. The average TA levels were also dependent on flesh color, whish was significantly higher in general sweet potato and orange sweet potato than in purple sweet potato. Steaming, baking, and frying processes significantly reduced AA (10.61~58.41%), DHA (2.57~52.81%), and TA (14.54~49.92%) contents in sweet potatoes. The highest reduction of AA, DHA, and TA contents was observed after baking, followed by steaming and frying. We expect that the basic information provided by this study will be useful to plant breeders and food scientists.

Modification and Validation of Analytical Method for Oxypaeoniflorin and Paeoniflorin in Moutan Cortex Radicis Extract (목단피 추출물의 Oxypaeoniflorin 및 Paeoniflorin의 분석법 개선 및 검증)

  • Choi, Seung-Hyun;Yoo, Chang-Kil;Hwang, Ji-Hyun;Lee, Gi-Bbeum;Lee, Young-Jin;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1091-1096
    • /
    • 2017
  • The aim of this study was the validation of a modified analytical method for determination of oxypaeoniflorin and paeoniflorin in Moutan Cortex Radicis extract. For validation of the analytical method, we modified established analytical methods and validated improvement. For validation, the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification of oxypaeoniflorin and paeoniflorin were measured by high performance liquid chromatography. The results show that the correlation coefficients of the calibration curve for oxypaeoniflorin and paeoniflorin were 1.0000 and 0.9998, respectively. The LOD for oxypaeoniflorin and paeoniflorin were $0.23{\mu}g/mL$ and $0.25{\mu}g/mL$, respectively. The inter-day and intra-day precision values of oxypaeoniflorin and paeoniflorin were 0.70~3.19% and 1.74~2.43%, and 0.32~0.92% and 0.62~2.28%, respectively. The inter-day and intra-day accuracies of oxypaeoniflorin and paeoniflorin were 98.33~102.11% and 97.72~118.12%, and 98.44~101.56% and 97.10~112.00%, respectively. Therefore, the analytical method was validated for the detection of oxypaeoniflorin and paeoniflorin in Moutan Cortex Radicis.

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy (경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가)

  • Chung, Hyun-Woo;Choi, Joon-Young;Kim, Young-Wook;Kim, Dong-Ik;Do, Young-Soo;Lee, Eun-Jeong;Lee, Su-Jin;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.316-321
    • /
    • 2006
  • Purpose: Differential diagnosis between arteriovenous (AVMs) aud non-arteriovenous malformations (nAVMs) is important in patients with congenital vascular malformations, because AVMs can cause hemodynamic alteration and require immediate treatment. We investigated whether transarterial lung perfusion scintigraphy (TLPS) was useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities. Materials and Methods: Fifty-seven patients (M:F=26:31, $21{\pm}13$ yr, 9 upper and 48 lower extremities) suspected of congenital vascular malformations in extremities underwent TLPS using $^{99m}Tc-MAA$ before embolization/sclerotherapy. Dose-corrected shunt fraction (SF) was calculated from time-activity curve of the lung. Final diagnosis of AVMs was determined by angiography. in patients with AVMs, follow-up TLPS was done for post-therapeutic evaluation. Results: Sixteen patients (8 upper and 8 lower extremities) had AVMs, while the remaining 41 had nAVMs (1 upper and 40 lower extremities). The mean SF of AVMs on TLPS was significantly higher than that of nAVMs ($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$), p=0.003). The sensitivity, specificity, and accuracy of TLPS (cut-off of SF = 20.0%) in diagnosis of AVMs before treatment were 93.8% (15/16), 100% (41/41) and 98.2% (56/57), respectively. The follow-up TLPS and angiography for post-therapeutic evaluation showed concordant results in 13 of 16 patients (81.3%) with AVMs. The mean SF of TLPS was significantly decreased after embolization/sclerotherapy ($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p=0.01). Conclusion: TLPS provides hemodynamic information of AVMs in extremities semiquantitatively. Furthermore, the results of TLPS showed a high concordance rate with angiographic findings. Therefore, TLPS is useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities.

Nonhydrostatic Effects on Convectively Forced Mesoscale Flows (대류가 유도하는 중규모 흐름에 미치는 비정역학 효과)

  • Woo, Sora;Baik, Jong-Jin;Lee, Hyunho;Han, Ji-Young;Seo, Jaemyeong Mango
    • Atmosphere
    • /
    • v.23 no.3
    • /
    • pp.293-305
    • /
    • 2013
  • Nonhydrostatic effects on convectively forced mesoscale flows in two dimensions are numerically investigated using a nondimensional model. An elevated heating that represents convective heating due to deep cumulus convection is specified in a uniform basic flow with constant stability, and numerical experiments are performed with different values of the nonlinearity factor and nonhydrostaticity factor. The simulation result in a linear system is first compared to the analytic solution. The simulated vertical velocity field is very similar to the analytic one, confirming the high accuracy of nondimensional model's solutions. When the nonhydrostaticity factor is small, alternating regions of upward and downward motion above the heating top appear. On the other hand, when the nonhydrostaticity factor is relatively large, alternating updraft and downdraft cells appear downwind of the main updraft region. These features according to the nonhydrostaticity factor appear in both linear and nonlinear flow systems. The location of the maximum vertical velocity in the main updraft region differs depending on the degrees of nonlinearity and nonhydrostaticity. Using the Taylor-Goldstein equation in a linear, steady-state, invscid system, it is analyzed that evanescent waves exist for a given nonhydrostaticity factor. The critical wavelength of an evanescent wave is given by ${\lambda}_c=2{\pi}{\beta}$, where ${\beta}$ is the nonhydrostaticity factor. Waves whose wavelengths are smaller than the critical wavelength become evanescent. The alternating updraft and downdraft cells are formed by the superposition of evanescent waves and horizontally propagating parts of propagating waves. Simulation results show that the horizontal length of the updraft and downdraft cells is the half of the critical wavelength (${\pi}{\beta}$) in a linear flow system and larger than ${\pi}{\beta}$ in a weakly nonlinear flow system.