• Title/Summary/Keyword: high SNR

Search Result 673, Processing Time 0.027 seconds

The strategy to catch more early light curves of supernovae

  • Hwang, Jeeun;Im, Myungshin;Paek, Gregory S.H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.71.3-72
    • /
    • 2021
  • The Intensive Monitoring Survey of Nearby Galaxies (IMSNG) is a high cadence observation program monitoring nearby galaxies at < 50 Mpc with high probabilities of hosting supernovae (SNe). The current number of main IMSNG targets is 60, but with new wide-field facilities joining IMSNG, there is a possibility of increasing the likelihood of catching the early light curves of SNe among galaxies in the vicinity of the main targets. To test the feasibility of the expansion of the sample galaxies, we examine how much the probability of catching SNe increases by adjusting the field of view of the RASA36 telescope which is one of the IMSNG facilities with a large field of view of 6.25 deg2. We calculate supernova rates (SNRs) of galaxies within the FoV that contains main IMSNG galaxies from the stellar mass and star formation rate of the galaxies. Based on the SNRs of these galaxies, we find the best pointing of the telescope towards the highest SNR region. As a result, we present improved total SNR, with respect to the ordinary pointing on average where the IMSNG main target is placed at the center of FoV. The actual observation should be followed to test the effect of this strategy.

  • PDF

Volume-sharing Multi-aperture Imaging (VMAI): A Potential Approach for Volume Reduction for Space-borne Imagers

  • Jun Ho Lee;Seok Gi Han;Do Hee Kim;Seokyoung Ju;Tae Kyung Lee;Chang Hoon Song;Myoungjoo Kang;Seonghui Kim;Seohyun Seong
    • Current Optics and Photonics
    • /
    • v.7 no.5
    • /
    • pp.545-556
    • /
    • 2023
  • This paper introduces volume-sharing multi-aperture imaging (VMAI), a potential approach proposed for volume reduction in space-borne imagers, with the aim of achieving high-resolution ground spatial imagery using deep learning methods, with reduced volume compared to conventional approaches. As an intermediate step in the VMAI payload development, we present a phase-1 design targeting a 1-meter ground sampling distance (GSD) at 500 km altitude. Although its optical imaging capability does not surpass conventional approaches, it remains attractive for specific applications on small satellite platforms, particularly surveillance missions. The design integrates one wide-field and three narrow-field cameras with volume sharing and no optical interference. Capturing independent images from the four cameras, the payload emulates a large circular aperture to address diffraction and synthesizes high-resolution images using deep learning. Computational simulations validated the VMAI approach, while addressing challenges like lower signal-to-noise (SNR) values resulting from aperture segmentation. Future work will focus on further reducing the volume and refining SNR management.

Spectral Characteristics of FBGs Inscribed in Polarization-Maintaining Fiber with Two Side Holes (두 개의 Side Hole을 가진 편광유지 광섬유에 새겨진 단주기 격자의 스펙트럼 특성)

  • Im, Ju-Eun;Sim, Chan-Uk;Kim, Tae-Hun;Nam, Ho-Cheol;Jeong, Yeong-Ju
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.405-406
    • /
    • 2008
  • In this paper, we will discuss the spectral characteristics of fiber Bragg gratings (FBGs) inscribed in two different types of polarization-maintaining fibers with side holes. One showed high signal-to-noise ratio (SNR), narrow bandwidth and high bending sensitivity, while the other one showed insensitivity to bending due to the small size of the side holes.

  • PDF

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.

A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System (디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.351-359
    • /
    • 2015
  • This convergence study analyzed the effectiveness of digital radiography system of copper(Cu) filter in the added filtration for the removal of lower energy radiation through dose and image evaluation. We were analyzed from April to June 2015 result of the examination. Cu filter was applied to each non, 0.1, 0.2, 0.3 mm according to change of kV and mAs and doses were evaluated. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of national cancer checkup. The absorbed doses with Cu were lowered by 16-88 % than non-filter but the gaps decreased as kV increased. PSNR were over 30 dB and all significant and CNR and SNR were superior with non-filter but in the qualitative analysis, there were different statistical significant according to each item. The score of 0.1 mm filter was high at pulmonary blood vessel observation and in the 0.3 mm Cu, there were no statistical signigicant except high density and full of air portion. Cu filter can improve image quality with lower radiation dose using better radiation quality and correction power at digital radiography system.

DVB-S2-based T4 class common data link performance improvement plan for UAV system application (무인기 체계 적용을 위한 DVB-S2 기반 T4급 공용데이터링크 성능 개선방안)

  • Bae, Jongtae;Baek, Seongho;Oh, Jimyung;Lee, Sangpill;Song, Choongho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.12
    • /
    • pp.1846-1854
    • /
    • 2022
  • The sophistication and diversification of mission equipment for surveillance and reconnaissance is leading to a demand for large-capacity public data links. Overseas, a T4 class(274Mbps) common data link was applied to the Global hwak, a high-altitude unmanned aerial vehicle, and various research and development are being conducted in Korea. In this paper, we propose a structure in which pilot is additionally applied to improve SNR performance while minimizing data transmission rate loss in the DVB-S2 frame structure, which is a european satellite broadcasting standard, for high-capacity transmission of T4 class or higher in the common data link. For the performance evaluation of the proposed structure, the performance of the DVB-S2 was compared and analyzed by simulating the UAV data link channel environment. As a result of simulation, 0.15% of transmission rate loss occurred at T4 class transmission rate compared to DVB-S2 in the proposed structure, but improved SNR reception performance of 0.2~0.3dB was confirmed in the UAV channel environment.

The Evaluation of Image Quality in Gradient Echo MRI of the Pancreas : Comparison with 2D T1 FFE and 3D T1 THRIVE Imaging (췌장 경사자기장에코 자기공명영상에서 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • The purpose of this analysis is to compare 2D T1 FEE and 3D T1 THRIVE for demonstration of the pancreas. A total of 85(45 men, 40 women; 58 years) PACS network datum were analysis clinically indicated pancreas MRI at 1.5 T. The SNRs and CNRs of 3D T1 THRIVE(SNR: $46.42{\pm}0.67$, CNR: $28.16{\pm}0.50$) showed significantly higher values than those from 2D T1 FEE(SNR: $53.84{\pm}1.20$, CNR: $35.48{\pm}0.70$), p<0.05, The image quality of the 3D T1 THRIVE($2.63 {\pm}0.14$) was significantly superior to that with the 2D T1 FEE($2.2{\pm}0.05$), but 3D T1 THRIVE revealed several artifacts resulting in poor quality. In conclusion, The 3D T1 THRIVE technique with a 1.5 T resulting in improved SNRs, CNRs and image quality was demonstrated.

Minimization of Motion Blur and Dynamic MTF Analysis in the Electro-Optical TDI CMOS Camera on a Satellite (TDI CMOS 센서를 이용한 인공위성 탑재용 전자광학 카메라의 Motion Blur 최소화 방법 및 Dynamic MTF 성능 분석)

  • Heo, HaengPal;Ra, SungWoong
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.85-99
    • /
    • 2015
  • TDI CCD sensors are being used for most of the electro-optical camera mounted on the low earth orbit satellite to meet high performance requirements such as SNR and MTF. However, the CMOS sensors which have a lot of implementation advantages over the CCD, are being upgraded to have the TDI function. A few methods for improving the issue of motion blur which is apparent in the CMOS sensor than the CCD sensor, are being introduced. Each pixel can be divided into a few sub-pixels to be read more than once as is the same case with three or four phased CCDs. The fill factor can be reduced intentionally or even a kind of mask can also be implemented at the edge of pixels to reduce the blur. The motion blur can also be reduced in the TDI CMOS sensor by reducing the integration time from the full line scan time. Because the integration time can be controlled easily by the versatile control electronics, one of two performance parameters, MTF and SNR, can be concentrated dynamically depending on the aim of target imaging. MATLAB simulation has been performed and the results are presented in this paper. The goal of the simulation is to compare dynamic MTFs affected by the different methods for reducing the motion blur in the TDI CMOS sensor.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .