• 제목/요약/키워드: high LET

검색결과 288건 처리시간 0.025초

고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정 (LET Calibration of Fe 500 MeV/u Ions using SSNTD)

  • 김성환
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.41-45
    • /
    • 2016
  • In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ($\overline{y_D}$) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.

LET 증가에 따른 회복 생존 모델의 파라미터 값 비교 (Comparison of Parameter Using the Repair Survival Model Irradiated High-LET)

  • 최은애
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.177-181
    • /
    • 2017
  • 방사선 생물학적 효과(Radio biological effectiveness, RBE)를 선량에 대부분 의존하는 X선과 달리 탄소빔의 경우 LET의 변화량은 반드시 고려되어야할 사항이다. 이는 X선 과는 극히 대조적인 선량 분포도를 갖고 있기 때문이며 LET의 변화량이 중요한 이유가 된다. 따라서 기존의 LQ 모델이나 회복생존모델의 경우 이러한 점이 감안되지 않아 탄소빔의 분할 조사 시 문제점을 보이며 오류를 보이고 있다. 본 연구에서는 약 $75keV/{\mu}m$의 고LET 탄소빔 분할 조사 시 Potentially Lethal Damage Repair (PLDR)의 발생양을 확인하고 약 $13keV/{\mu}m$ 저LET 조사와 비교하여 현저히 감소하였음을 확인하였다. PLDR의 감소에 따라 생존율 또한 감소하였다. 따라서 탄소빔의 생물리학적 모델 개발에 LET의 변화량은 반드시 고려되어져야 할 것으로 보인다.

프로토 타입 조직등가비례계수기의 중입자가속기연구소의 135 MeV/u 탄소 이온에 대한 선형에너지 스펙트럼 측정 (Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC)

  • 남욱원;이재진;표정현;박원기;문봉곤;임창휘;문명국;하시시 키다무라;신고 고바야시;김성환
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.197-201
    • /
    • 2014
  • TEPC (Tissue Equivalent Proportional Counter) was usually used for high LET radiation dosimetry. We developed a prototype TEPC for micro-dosimetry in the range of $0.2{\sim}300 keV/{\mu}m$. And, the simulated site diameter of the TEPC is $2{\mu}m$, of similar size to a cell nucleus. For purposes of characterization the response for high LET radiation of the TEPC has been investigated under 135MeV/u Carbon ions in HIMAC (Heavy Ion Medical Accelerator). We determined the gas multiplication factor and measured the lineal energy spectrum [yd(y)] of 135 MeV/u Carbon ions. The value of the gas multiplication factor was 315 at 700 V bias voltage. As a result of the experiment, we could more understand the performance of the TEPC for high LET (Linear Energy Transfer) radiation. And the procedure of high LET radiation dosimetry using TEPC is established.

저밀도 이광자 광중합 영역을 이용한 30 nm 이하의 패턴제작 (Fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region)

  • 박상후;임태우;양동열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1249-1253
    • /
    • 2007
  • Experimental studies on the fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region have been carried out. For the generation of nanofibers inside or outside microstructures, an over-polymerizing method involving a long exposure technique (LET) was proposed. Such nanofibers can find meaningful applications as bio-filters, mixers, and many other uses in diverse research field. A multitude of nanofibers with a notably high resolution (about 22 nm) in two-photon polymerization was achieved using the LET. Furthermore, it was demonstrated that the LET can be employed for the direct fabrication of various embossing patterns by controlling the exposure duration and the interval between voxels. Thin interconnecting networks are formed regularly in the boundary of the over-polymerized region, which allows for the creation of various pattern shapes. Overall of this work, some patterns including nanofibers are fabricated by the LET.

  • PDF

안료분산 및 희석용 실리콘/아크릴수지의 배합비에 따른 고내후성 물성비교 (Weatherability Comparison with Changing Mixing Ratios of Mill-Base and Let-Down Silicone/Acrylic Resins)

  • 박홍수;김송형;함현식
    • 한국응용과학기술학회지
    • /
    • 제24권3호
    • /
    • pp.253-263
    • /
    • 2007
  • Three different weather-resistant coatings were fabricated with the various weight ratios of a mill-base silicone/acrylic resin to let-down silicone /acrylic resin at 2:8, 3:7, and 4:6 respectively. The prepared coatings were tested to investigate the effect of composition of weather-resistant coatings on the physical properties. The thermal stability, salt spray exposure, and weather-resistance were improved with the increased silicone content. It was concluded that the optimum retio of mill-base silicone/acrylic resin to let-down silicone/acrylic resin would be 2:8 and the coating with 30 wt% of silicone content would have high weather-resistance.

400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정 (Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions)

  • 김성환;남욱원;이재진;박원기;표정현;문봉곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.43-49
    • /
    • 2016
  • 본 연구에서는 탄소이온을 이용한 고LET 방사선 치료시 CR-39 고체비적검출기(SSNTD)를 선량계로 사용하기 위하여 일본 중입자가속기연구소(HIMAC)의 400 MeV/u 탄소 이온을 이용한 교정실험을 수행하였다. 탄소 이온을 조사한 CR-39 검출기는 일본 우주항공연구개발기구(JAXA)의 고체비적검출기 전처리 프로토콜에 따라 화학적 에칭을 하였고, 에칭된 CR-39 검출기의 표면에 형성된 트랙은 디지털 카메라로 촬영한 후 Image J를 이용하여 분석하였다. 분석결과 400 MeV/u 탄소 이온의 ${\bar{y_F}}$${\bar{y_D}}$는 각각 $8.5keV/{\mu}m$$10.1keV/{\mu}m$이었으며, 이 결과는 한국천문연구원의 조직등가비례계수기(TEPC)로 측정한 값 및 GEANT4 몬테칼로 시뮬레이션으로 계산한 값과 잘 일치하였다. 본 연구를 통하여 CR-39의 선량 및 LET 교정인자를 결정할 수 있었으며, 고LET 방사선 치료시 CR-39를 이용한 선량평가의 가능성을 확인하였다.

Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u-1 Carbon Ions

  • Hirata, Yuho;Watanabe, Kenichi;Uritani, Akira;Yamazaki, Atsushi;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.222-228
    • /
    • 2016
  • Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.

Relationships between LET and RBE of lonizing Radiation in the induction of Somatic Mutations of Drosophila melanogaster

  • 유미애;정운혁;이원호
    • 한국환경성돌연변이발암원학회지
    • /
    • 제7권2호
    • /
    • pp.103-111
    • /
    • 1987
  • The effects of LET (linear energy transfer) of radiation on the induction of somatic chromosome mutations or gene mutations of Drosophila melanogaster were studied. For detecting somatic chromosome mutations and gene mutations, Drosophila wing spot system and eye-color spot system were used, respectively. The frequencies of somatic chromosome mutations or gene mutations induced after third instar larval treatment with 23 MeV neutrons, thermal neutrons, X-rays were examined. From these data, the RBE(relative biological effectiveness) values of 23 MeV neutrons relative to X-rays for induction of somatic chromosome mutations or gene mutations were calculated. The present results suggest that high LET radiations are efficient than X-ray in producing not only somatic chromosome mutations but also gene mutations.

  • PDF

저밀도 이광자 광중합 영역의 중첩방법을 이용한 기능성 마이크로 채널 제작에 관한 연구 (Fabrication of Microchannels Having Sub-30 nm Nanofibers Inside of Them via Overlapping Weakly Two-Photon Polymerized Region)

  • 박상후;임태우;양동열
    • 대한기계학회논문집A
    • /
    • 제31권12호
    • /
    • pp.1144-1149
    • /
    • 2007
  • Experimental studies on the fabrication of sub-30 nm nanofibers using weakly two-photon induced photopolymerized region have been carried out. For the generation of nanofibers inside or outside microstructures, an over-polymerizing method involving a long exposure technique (LET) was proposed. Such nanofibers can find meaningful applications as bio-filters, mixers, and many other uses in diverse research field. A multitude of nanofibers with a notably high resolution (about 22 nm) in two-photon polymerization was achieved using the LET. Furthermore, it was demonstrated that the LET can be employed for the direct fabrication of various embossing patterns by controlling the exposure duration and the interval between yokels. Thin interconnecting networks are formed regularly in the boundary of the over-polymerized region, which allows for the creation of various pattern shapes. Overall of this work, some patterns including nanofibers are fabricated by the LET.

2중 한류 구조를 갖는 배선용 차단기의 차단성능 평가 연구 (A Study on Estimation of Interrupting capability on Molded Case Circuit Breaker including Current Limiting Unit)

  • 김용기;송중천;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.144-146
    • /
    • 2002
  • The latest development flow of MCCB(Molded Case Circuit Breaker) is largely separated from which are high capability of interrupting compact of size and multi-ability in functions. As follow of development of industrial system. MCCB which are including communication function and having a ultimate interrupting capability is required in electrical system. to attain an effective limitation of the peak let-through current and the let-through energy, the arc has to move rapidly off the contacts and has to increase the arc voltage which mainly effect to interrupt. In this paper. we made high performance circuit breaker which including current limiting unit which is attached to the main which is simulated by CAE tool that are repulsion force and mechanical dynamics after that we tested and finally selected optimized for circuit breaker.

  • PDF