• Title/Summary/Keyword: high K

Search Result 125,639, Processing Time 0.104 seconds

Three-dimensional Refractive-index Distributions of Individual Angiosperm Pollen Grains

  • Park, Chansuk;Lee, SangYun;Kim, Geon;Lee, SeungJun;Lee, Jaehoon;Heo, Taehyun;Park, Yoonjeong;Park, YongKeun
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.460-467
    • /
    • 2018
  • Three-dimensional (3D) refractive-index (RI) imaging and quantitative analyses of angiosperm pollen grains are presented. Using optical diffraction tomography, the 3D RI structures of individual angiosperm pollen grains were measured without using labeling or other preparation techniques. Various physical quantities including volume, surface area, exine volume, and sphericity were determined from the measured RI tomograms of pollen grains. Exine skeletons, the distinct internal structures of angiosperm pollen grains, were identified and systematically analyzed.

A Study on the Charateristics of the Korean Adult Female Sound According to Sasang Constitution Using PSSC with a Sentence (사상체질음성분석기(四象體質音聲分析機)(PSSC)를 통한 한국인 성인여성(成人女性)의 체질별(體質別) 음향특성연구(音響特性硏究) - 단문(短文)을 중심으로 -)

  • Youn, Ji-Young;Yoon, Woo-Young;Cho, Sung-Eon;Wang, Hyang-Lan;Jeon, Jong-Weon;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.3
    • /
    • pp.75-93
    • /
    • 2006
  • 1. Objectives and Methods Sasang Constitutional Medicine is the original Korean Medicine. The purpose of this study was to objectify the diagnosis of Sasang Constitution. 212 Women's sentences were analyzed into 228 factors like Pitch, APQ, Shimmer, Octave and Energy, etc. Women's sentences were classified into 3 categories: total group, under 54 years old group and over 55 years old group. 2. Results 1) In Total group Soyangin's Center feq.(3) was significantly high compared with Taeyangin and Taeumin groups. Taeumin's Pitch2 was significantly high compared with Soeumin and Taeyangin groups. Taeyangin's Pitch S.D. was significantly high compared with Soyangin group. Taeyangin's Octave6 was significantly high compared with Soeumin group. There were no significant differences among constitutional groups in APQ and Shimmer segment. On the point of Energy, Taeyangin's G Tot E(1), G# Tot E(1), G dev.(1), G# dev.(1), G Tot E(2), G# Tot E(2), G dev.(4) and G# dev.(4) were significantly high compared with other groups. Soyangin's A#S.D.(2) was significantly high compared with Taeyangin group. Taeyangin's A#S.D.(3) was significantly high compared with Taeumin group. Taeyangin's F S.D.(5), F# S.D.(5) and Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 and Peak4 were significantly high compared with Taeyangin group. Taeumin's PeakValue1 was significantly high compared with Soeumin group. Taeyangin's PeakValue2 was significantly high compared with Soeumin group. Taeyangin's PeakValue3 and PeakValue5 were significantly high compared with Other groups. 2) In Under 54 years old group, there were no significant differences among constitutional groups in APQ, Shimmer and Octave segment. Taeumin's Center freq.(2) was significantly high compared with Taeyangin and Soyangin groups. Taeumin's Pitch(2) and Pitch(3) were significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's Pitch S.D. were significantly high compared with Soyangin group. Taeyangin's and Soyangin's Octave2 were significantly high compared with Taeumin group. On the point of Energy, Taeyangin's and Soyangin's A# S.D.(2) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's G# dev.(1), G# dev.(2) were significantly high compared with Taeumin group. Taeyangin's and Taeumin's F# S.D.(3) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 was significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's PeakValue2 were significantly high compared with Soeumin group. Taeyangin's and Soeumin's PeakValue3 were significantly high compared with Taeumin group. Taeyangin's and Soyangin's PeakValue5 were significantly high compared with Soeumin group. Taeyangin's and Soyangin's PeakValue9 were significantly high compared with Taeumin group 3) In Over 55 years old group, there were no significant differences among constitutional groups in Pitch, APQ, and Peak segment. Soeumin's F Shimmer(1) and F Shimmer(2) were significantly high compared with Taeyangin and Taeumin groups. Soeumin's G# Shimmer(1) and G# Shimmer(2) were significantly high compared with Soyangin group. Taeyangin's Octave5 and Octave6 were significantly high compared with Soeumin group. On the point of Energy, Soyangin's C S.D., F# S.D.(1), F# S.D.(2) and G dev.(2) were significantly high compared with other groups. Soyangin's F# S.D.(3) was significantly high compared with Taeumin and Soeumin groups. Taeyangin's and Taeumin's G# S.D.(2) and G# S.D.(3) were significantly high compared with Soyangin group 3. Conclusions From above result, there is the possibility of efficient standard guide for constitution diagnosis by analysis of voice

  • PDF

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

Assessing the Prevalence of Recurrent Neck and Shoulder Pain in Korean High School Male Students: A Cross-sectional Observational Study

  • Koh, Min-Jung;Park, Sun-Young;Woo, Young-Sun;Kang, Sung-Hyun;Park, Sang-Hoon;Chun, Hye-Jung;Park, Eun-Jung
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.161-167
    • /
    • 2012
  • Background: Neck and shoulder pain (NSP) is fairly common in adolescents, which is associated with a high prevalence of NSP found during adulthood as well; therefore, its significance during adolescence should not be underestimated. We surveyed the prevalence of recurrent NSP, lifestyle, and risk factors in Korean high school students, and examined the influence of recurrent NSP on the quality of life. Methods: Nine hundred thirty one male students (16-19 years old) from two academic high schools in Seoul were included in this study. The survey consisted of a questionnaire to assess the prevalence of recurrent NSP, with questions regarding having an occurrence more than once a week, characteristics of NSP, activity and lifestyle of the students, and the risk factors for recurrent NSP. A 36-item Short Form questionnaire was also examined. Results: We found that 44.3% of the high school students surveyed had recurrent NSP (more than once a week) and the overall prevalence of NSP was 79.1%. The average sitting time was $10.2{\pm}2.7$ h/day. 59.0% did not sit straight, 14.7% used assisting devices during reading, and 11.9% answered that they stretched regularly. Found from their self assessed health, frequent fatigue and frequent depressed mood presented significant associations with the higher prevalence of recurrent NSP. Conclusions: Korean high school students had a high prevalence of recurrent NSP. Clinical attention is needed for the prevention and resolution of recurrent NSP found in high school students.

A 16kw Rotating Anode type Monoblock X-ray Generator (16kW 회전 Aonde형 모노블럭 X-선 발생장치)

  • Oh, Jun-Yong;Kim, Yuen-Chung;Kim, Hack-Seong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • This paper designs mono block type with rotating high power radiography x-ray generator and studies 16kW X-ray generator possible to adapt hospital mobile radiography and industrial X-ray equipment and design. This equipment uses rotating anode type x-ray tube at high voltage generator to generate x-ray and adds rotor operating circuit to operate rotor of x-ray tube. The size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of x-ray tube voltage and tube current correspond to variable load.

CS-PDM Series Resonant High Frequency Inverter for Copy Machine

  • Sugimura, Hisayuki;Eid, Ahmad Mohamad;Hiraki, Eiji;Kim, Sung-Jung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1066-1071
    • /
    • 2005
  • This paper presents the two lossless auxiliary inductors-assisted voltage source type half bridge (single ended push pull: SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimental ones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proved from the practical point of view.

  • PDF

Main Factors that Effect on the Ion-Migration of PCB (PCB의 이온-마이그레이션에 영향을 미치는 주요요인)

  • Jang, In-Hyeok;Kim, Jeong-Ho;Oh, Gil-Gu;Lee, Young-Joo;Lim, Hong-Woo;Choi, Youn-Ok
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.202-207
    • /
    • 2016
  • Purpose: The purpose of this study is main factors (environmental conditions, pattern spacing, pattern material) that effect the ion-migration of PCB. Methods: Recently, the electronic components are becoming more high density of electronic device, so that electronic circuits have smaller pitches between the patten and more vulnerable to insulation failure. so the reliability of electric insulation of device has become an ever important issue as device contact pitches of pattern. Usually, ion-migration occurs in high temperature and high humidity environment as voltage is applied to the circuit. Under high temperature and high humidity, voltage applied electronic components respond to applied voltages by metals's electrochemical ionization and a conducting filament forms between the anode and cathode across a nonmetallic medium. This leads to short-circuit failure of the electronic component. Results: we studied ion-migration that occurs in accordance with the main factors (environmental conditions, pitches, pattern material). The PCB pattern material was made by two different types of material (free solder, OSP) for this research and pitches of pattern is 0.15mm, 0.3mm, 0.5mm. PCB was experimented in the environmental conditions (high temperature $120^{\circ}C$, high temperature and high humidity $85^{\circ}C$, 85%RH) and was analyzed for ion-migration through the experiment results. Conclusion: We confirmed that environmental condition, pitches of pattern, pattern material had effect on ion-migration of PCB.

Soil organic carbon characteristics relating to geomorphology near Vestre Lovénbreen moraine in Svalbard

  • Jung, Ji Young;Lee, Kyoo;Lim, Hyoun Soo;Kim, Hyun-Cheol;Lee, Eun Ju;Lee, Yoo Kyung
    • Journal of Ecology and Environment
    • /
    • v.37 no.2
    • /
    • pp.69-79
    • /
    • 2014
  • Soil organic carbon (SOC) in the Arctic is vulnerable to climate change. However, research on SOC stored in the high Arctic regions is currently very limited. Thus, this study was aimed at understanding the distribution and characteristics of SOC with respect to geomorphology and vegetation in Svalbard. In August 2011, soil samples were collected near the Vestre Lov$\acute{e}$nbreen moraine. Sampling sites were chosen according to altitude (High, Mid, and Low) and differences in levels of vegetation establishment. Vegetation coverage, aboveground biomass, and SOC contents were measured, and density-size fractionation of SOC was conducted. The SOC content was the highest in the Mid site ($126.9mg\;g^{-1}$) and the lowest in the High site ($32.1mg\;g^{-1}$), although aboveground biomass and vegetation coverage were not different between these two sites. The low SOC content measured at the High site could be related to a slower soil development following glacial retreat. On the other hand, the Low site contained a high amount of SOC despite having low vegetative cover and a high ratio of sand particles. These incompatible relationships between SOC and vegetation in the Low site might be associated with past site disturbances such as runoff from snow/glacier melting. This study showed that geomorphological features combined with glacier retreat or melting snow/glacier effects could have affected the SOC distribution and vegetation establishment in the high Arctic.

What factors reduce the yield potentiality in high-yielding rice?

  • Kobata, Tohru;Yoshida, Haruka;Masiko, Uukina;Honda, Tohru;Ishi, Hibiki;Iwasaki, Hiroyuki
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.19-19
    • /
    • 2017
  • The indica ${\times}$ japonica rice (Oryza sativa L.) cultivars released in Japan since 1980 are high-yielding. However, occasionally in these cultivars their high yield potentials cannot be realized, particularly depending on climate conditions. The objectives of this study were to identify the reason for yield instability and the critical yield component factor causing lower grain yield in these high-yielding cultivars. Standard-yield japonica, high-yielding japonica-dominant, and indica-dominant cultivars were grown in western Japan. Rough grain yield (RY) in these high-yielding cultivars ranged from 450 to $980g\;m^{-2}$, and was positively correlated with potential grain yield (PRY). By fluctuations of solar radiation, RY changed with spikelet number (SNO), and SNO was correlated with cumulative radiation during the panicle formation period of 30 days before heading. Even if higher SNO was achieved under higher radiant conditions, RY was lower than PRY. The lower grain-filling in plants bearing higher SNO resulted from a lower filling percentage of spikelets (%F, RY/PRY), and %F was strongly correlated with spikelet fertility (%S) across all cultivars. %S was highly influenced by cumulative radiation per PRY during pollen development and establishment around heading. Inhibition of assimilation by leaf removal lowered %S. Conversely, stem thinning and removal of upper panicles around heading increased %S in spikelets of the lower part of the panicle in which sterility was higher. These results suggest that limitation of assimilate-supply due to low irradiance at the spikelet-formation and flowering stages restrains the potential of the high-yielding cultivars, depending on reduction of SNO and %S, respectively.

  • PDF

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.