• Title/Summary/Keyword: high K

Search Result 125,621, Processing Time 0.1 seconds

Performance-Based Seismic Design for High-Rise Buildings in Japan

  • Nakai, Masayoshi;Koshika, Norihide;Kawano, Kenichi;Hirakawa, Kiyoaki;Wada, Akira
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.155-167
    • /
    • 2012
  • This paper introduces the outlines of review and approval processes, general criteria and usual practices taken in Japan for the seismic design of high-rise buildings. The structural calculations are based on time-history analyses followed by performance evaluations. This paper also introduces structural design of two high-rise buildings: one is a 100 m high reinforced concrete residential building, and the other is a 300 m high steel building for mixed use.

Development of the High Temperature Silicon Pressure Sensor (고온용 실리콘 압력센서 개발)

  • Kim, Mi-Mook;Nam, Tae-Chul;Lee, Young-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.175-181
    • /
    • 2004
  • A pressure sensor for high temperature was fabricated by using a SDB(Silicon-Direct-Bonding) wafer with a Si/$SiO_{2}$/ Si structure. High pressure sensitivity was shown from the sensor using a single crystal silicon of the first layer as a piezoresistive layer. It also was made feasible to use under the high temperature as of over $120^{\circ}C$, which is generally known as the critical temperature for the general silicon sensor, by isolating the piezoresistive layer dielectrically and thermally from the silicon substrate with a silicon dioxide layer of the second layer. The pressure sensor fabricated in this research showed very high sensitivity as of $183.6{\mu}V/V{\cdot}kPa$, and its characteristics also showed an excellent linearity with low hysteresis. This sensor was usable up to the high temperature range of $300^{\circ}C$.

The estimation of uncertainty in new measuring system used for high-power tests (대전력시험의 새로운 측정시스템에 대한 불확도 평가)

  • Suh, Yoon-Taek;Kim, Maeng-Hyun;Kim, Dae-Won;Kang, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.540-542
    • /
    • 2003
  • In the high-power tests to be performed on electrical apparatus as circuit-breaker, load switch, fuse, transformers, insulators, cable and so on, the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper deals with factors of uncertainty and describes estimation of uncertainty in new measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters (Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화)

  • Kim, Maeng-Hyun;Rhyou, Hyeong-Kee;Park, Jong-Wha;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

Rotor Loss Analysis of Permanent Magnet High-Speed Machine According to Magnetization Pattern

  • Cho, Han-Wook;Jang, Seok-Myeong;Lee, Sung-Ho;Yang, Hyun-Sup;Jeong, Yeon-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.103-107
    • /
    • 2004
  • Recently, greater attention has been paid to the high-speed generator for its many merits, such as ease of installation, high efficiency and high power density. However, due to their high fundamental frequency, careful consideration needs to be given to both electromagnetic and mechanical design issues. This paper deals with the comparison of two types of permanent magnet high-speed machines. Specifically, the effect of the permanent magnet magnetization pattern on the rotor losses is investigated. On the basis of analytical field analysis and the 2-D finite element method, this paper predicts the flux harmonics and rotor losses under the no-load condition. It is shown that the Halbach magnetization is superior to parallel magnetization in terms of producing rotor losses.

Effect of Red Pepper Seeds Powder on Lipid Composition in Rats Fed High-Fat.High-Cholesterol Diets

  • Song, Won-Young;Chun, Sung-Sik;Ku, Kyung-Hyung;Choi, Jeong-Hwa
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.3
    • /
    • pp.184-188
    • /
    • 2010
  • The purpose of the present study was to evaluate the effects of red pepper seeds powder on lipid metabolism in rats fed high fat high cholesterol diet. Rats were divided into five experimental groups: normal diet group, high fat high cholesterol diet group, high fat high cholesterol diet with 5% red pepper seeds powder supplemented group (SA group), high fat high cholesterol diet with 10% red pepper seeds powder supplemented group (SB group) and high fat high cholesterol diet with 15% red peeper seeds powder supplemented group (SC group). The serum triglyceride (TG) and cholesterol contents, and LDL-cholesterol and atherogenic index (AI) of the red pepper seed powder supplemented groups were significantly decreased compared to the HF group. The serum HDL-cholesterol contents of the red pepper seed powder supplemented groups were increased compared to the HF group. However, there was no significant difference in the serum HDL-cholesterol among all experimental groups. The hepatic TG and cholesterol contents of the red pepper seed powder supplemented groups were significantly decreased compared to the HF group. The fecal total cholesterol and triglyceride contents of the red pepper seeds powder supplemented groups were significantly increased compared to the HF group. These results suggest that supplementation of red pepper seed powder may have a pronounced impact on markers of lipid metabolism in serum and liver of rats fed high fat high cholesterol diets.

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

Verification of Running Safety Evaluation Method for High-speed Railway (고속열차 주행안전성 평가법에 대한 검증 연구)

  • Ryu, Sang-Hyun;Kim, Sang-Soo;Kim, Dae-Sik;Kim, Sang-Young;Hong, June-Hee;Lee, Ki-Jun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.310-317
    • /
    • 2014
  • The Next-generation High-speed Rail Technology Development Project was started in 2007 by the Korean Government with the aim of developing the core technologies for a high-speed electric multiple unit (EMU) railway system. This is the first attempt to develop a high-speed EMU railway. High-speed EMU trains have superior acceleration and deceleration compared to push-pull high-speed railways such as KTX(Korean Train eXpress). A prototype train was developed and tested on a high-speed line starting in 2012. The new train must maintain running safety during the test. Generally, the international standard (UIC518) is adopted to evaluate the running safety of trains. This method suggests that the test zone must have over 25 sections, and the length of each section must be 500 m. However, it is difficult to implement these test conditions for a real high-speed line. In this study, we analyzed the running safety using several test section lengths (100 m to 500 m) and compared the results. The results of this study will be used to establish a running safety evaluation method for high-speed EMU railways.

The Effects of Supungsunki-hwan Partitioned Prescriptions on Obese Type 2 Diabetes Mouse Model Induced by High Fat, High Carbohydrate Diet (수풍순기환 분할처방 투여가 고지방, 고탄수화물 식이로 유발된 비만형 제2형 당뇨병 동물모델에 미치는 영향)

  • Park, Eun-Young;Ahn, Se-Young;Ahn, Young-Min;Um, Jae-Young;Jang, Hyeung-Jin;Lee, Byung-Cheol
    • The Journal of Internal Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.387-396
    • /
    • 2011
  • Objectives : Recently a lot of research is being done for find antidiabetic medicine which has no side effects. This study aimed to investigate the antidiabetic and antiobesity effects of Supungsunki-hwan partitioned prescriptions on obese type 2 diabetes mouse. Methods : Type 2 diabetes mellitus and obesity were induced by Surwit's high fat, high sucrose diet for 8 weeks. Mice were divided into 3 groups of ND (normal diet, n=10) HFD (high fat and high sucrose diet, n=10) and SPP (high fat and high sucrose diet with Supungsunki-hwan partitioned prescriptions, n=10) groups. Body weights were measured every week. After 7 weeks, fasting blood sugar and oral glucose tolerance tests were conducted. After 8 weeks, blood samples of all mice were taken from their heart and analyzed biochemically. At the same time, epididymal fat pad and liver weights were measured. Histological size of white adipocyte were measured as well. Results : Compared with a HFD group, body weight, fructosamine, epididymal fat pad weight and white adipocyte size decreased. High-density lipoprotein cholesterol levels increased in the SPP group. Conclusions : These results suggest that SPP has antidiabetic and antiobesity effects in high fat, high sucrose diet induced obese mice.