• Title/Summary/Keyword: high $O_2$

Search Result 12,501, Processing Time 0.084 seconds

Anatomical Difference in Selectivity between Paddy Rice and Weed Species by Mixture Use of Oxyfluorfen and Bensulfuron (Oxyfluorfen 및 Bensulfuron 조합처리(組合處理)에 의한 벼 및 수종(數種) 잡초종간(雜草種間)의 선택반응상(選擇反應相)의 해부학적(解剖學的) 비교연구(比較硏究))

  • Guh, J.O.;Chon, S.U.;Han, S.U.;Kuk, Y.I.
    • Korean Journal of Weed Science
    • /
    • v.12 no.2
    • /
    • pp.132-143
    • /
    • 1992
  • The study was conducted to find out synergistic effects by interaction on the basis on anatomical changes between paddy rice and weed species by mixture use of oxyfluorfen and bensulfuron at 0, $10^{-6}$ and $10^{-4}$M, respectively. Tissues were sampled at 72 hrs after soaking treatment and prepared for light microscopic examination and sectioned longitudinally and transversely stem into $8{\mu}m$ thick. As the results of microscopic examination, the major response of treated plant involved rupture and constrict in mesophyll cells and epidermal cells, and shrinks in bundle sheath cells by oxyfluorfen and disorganization and swelling in meristems by bensulfuron. Anatomical changes in rice was the least affected by even high concentration and two herbicide mixtures, whereas Echinochloa crus-galli was severely disorganized in meristem regions and ruptured in epidermal cells by mixture use. Monochoria vaginalis was completely ruptured by any treatment concentrations and mixtures. Scirpus juncoides was considerably tolerant to both herbicides and their mixture and was similar to those that occur in rice. Perennial weed, Sagittaria pigmaea was observed vacuolation, non-nucleation of cell, and irregular cell layering but in mixture injury was slight. Cyperus serotinus was severely shrunk and ruptured by mixture treatment. Eventually anatomical variations in all weed species was shown synergistic effect by use of herbicide mixtures.

  • PDF

Variation of Selected Phenotypic Characteristics, Anthocyanins and Bitter Sesquiterpene Lactones in Lettuce (Lactuca sativa L.) Germplasm (상추(Lactuca sativa L.)유전자원의 형태 특성 및 Anthocyanins과 Bitter Sesquiterpene Lactones 변이)

  • Choi, Susanna;Assefa, Awraris Derbie;Lee, Jae-Eun;Hur, On-Sook;Ro, Na-Young;Lee, Ho-Sun;Noh, Jae-Jong;Hwang, Ae-Jin;Kim, Yeong-Jee;Kim, Bich-Saem;Ko, Ho-Cheol;Rhee, Ju-Hee
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.95-95
    • /
    • 2019
  • 상추(Lactuca sativa L.)는 대표적인 쌈 및 샐러드 채소로 우리나라 기준(2016년) 3,387 ha의 면적에서 86,128톤을 생산하여 엽채류 중 배추, 양배추 다음으로 많이 생산되는 작물이다. 안토시아닌(Anthocyanins)은 열매, 꽃, 줄기, 잎 등 식물계에 널리 분포되어 있는 페놀 화합물 중 하나로 적색, 자색 등의 색을 나타내는 수용성 flavonoid계 색소이다. BSLs (Bitter sesquiterpene lactones)는 항암, 항균, 해열과 염증완화에 효과가 있는 것으로 알려져 있다. 본 연구는 농촌진흥청 농업유전자원센터에서 보유 중인 상추 66자원의 형태학적 특성 및 액체크로마토그래피(HPLC, UPLC)를 이용한 안토시아닌과 BSLs성분을 분석하여 함량이 높은 자원을 선발하고자 한다. 상추시료 0.05 g을 $MeOH/H_2O/AcAc$로 추출 한 후, UPLC를 사용하여 안토시아닌 함량을 분석하였으며, 상추시료 0.25 g을 100% MeOH로 추출 한 후 HPLC를 사용하여 BSLs 함량을 분석하였다. 연구 결과, 상추 유전자원의 안토시아닌 함량 범위는 0 mg/100 g에서 371.94 mg/100 g이고, BSLs성분 함량 범위는 $60.28{\mu}g/g\;DW$에서 $2821.92{\mu}g/g\;DW$ 이었다. 상추 66자원 중 안토시아닌함량이 200 mg/100 g이상인 자원은 IT217012, IT218395, IT231524, IT231525, IT260852이며, BSLs 함량이 $1700{\mu}g/g\;DW$이상인 자원은 IT231524, IT231525, IT231527, IT264971, IT271118이다. 두 성분의 함량이 모두 높은 자원 IT231524와 IT231525 이었다. 이 두자원의 형태적 특성은 초형이 잎상추로 잎이 넓은 타원형에 가장자리 결각이 강한 자주색이다. 따라서 본 연구는 다양한 상추 유전자원의 형태학적 특성 및 BSLs, 안토시아닌 성분이 높은 자원을 선발하여 육종소재로 활용하고자 한다.

  • PDF

Effect of Nuruk protease activity on the quality of anchovy sauce (누룩의 protease 활성이 멸치액젓의 품질에 미치는 영향)

  • Lee, Myeong Hae;Jeong, In Hak;Jeong, Seok Tae;Chang, Yun Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.3
    • /
    • pp.356-363
    • /
    • 2021
  • This study investigated the quality characteristics of anchovy sauce fermented using Nuruk to maintain a unique flavor, reduce fishy smell, and improve the fermentation rate. Six kinds of fermented fish sauces, including the control, fermentation using traditional Nuruk; SH Koji (Fs-A), JJ Koji (Fs-B), GJ Koji (Fs-C); and fermentation with improved Nuruk; Aspergillus luchuensis (Fs-D) and Aspergillus oryzae (Fs-E), were prepared. Samples were collected at 15 days intervals with 10% Nuruk added to raw anchovy and fermented at 25o C for 60 days. The free amino acids, especially glutamic acid content and amino nitrogen, were the highest in Fs-C, reflecting the high protease activity of Nuruk C (GJ). Regarding overall sensory evaluation, the control was the lowest, whereas Fs-C was highly evaluated among the sample groups. The addition of Nuruk not only shortened the fermentation period, but also increased the overall sensory level by adding umami and reducing fishy odor.

The effects of fluoride releasing orthodontic sealants on the prevention and the progressive inhibition of enamel demiheralization in vitro (광중합형 및 자가중합형 교정용 전색제의 치아우식예방 및 진행억제효과에 관한 실험적 연구)

  • Chae, Seung-Won;Cho, Jae-O;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.979-995
    • /
    • 1997
  • The purpose of this study was to identify the preventive and the progressive inhibitory effects of enamel demineralization with fluoride releasing light-and self-cured orthodontic sealants(FluoroBond), in vitro, under the polarizing light microscope and the scanning electon microscope. The polarizing light microscopic group was subdivided into seven groups(Group A-Group G). The scanning electron microscopic group was also subdivided into seven groups(Group A'-Goup G'). For polarizing light microscopic evaluation, longitudinal sections were made longitudinally by Maruto cutter(Maruto Co., Japan) and Maruto grinding machine(Maruto Co., Japan). Sections were examined and photographed by the polarizing light microscope(Olympus Optical Co., Japan) using crossed polars and with the enamel rod longitudinal axis oriented at $45^{\circ}$ to the extinction position. For scanning electron microscopic evaluation, the specimens were coated with a highly conducting layer of gold palladium in a model Hus-4 high-vacuum evaporator and examined in an ISI-100B scanning electron microcope operated at 20kV. The results of this study were as follows : 1. The mean depths of artificial carious lesions under a polarized light microscope were $Group\;A(5.08{\mu}m),\;Group\;B(47.82{\mu}m,\;Group\;C(8.42{\mu}m),\;Group\;D(7.20{\mu}m),\;Group\;E(85.41{\mu}m),\;Group\;F(60.38{\mu}m),\;Group\;G(60.13{\mu}m)$. 2. There were statistically significant differences in Group B compared with Group A, C, and D(p<0.05), and also, in Group I compared with Group F and Group G(p<0.05). 3. Light-and self-cured orthodontic sealants had the preventive effects of enamel demineralization. 4. Light-and self-cured orthodontic sealants had the progressive inhibitory effects of enamel demineralization. 5. The time progress of demineralizing agent had no influence on the samples of light-and self-cured orthodontic sealants under the scanning electron microscope. 6. There was no difference between the specimens of light-and self-cured orthodontic sealants both in the polarized light microscopic group and in the scanning electron microscopic group.

  • PDF

Clinical Differential Diagnosis of Usual Interstitial Pneumonia from Nonspecific Interstitial Pneumonia (통상성 간질성 폐렴과 비특이성 간질성 폐렴의 임상적 감별 진단)

  • An, Chang-Hyeok;Koh, Young-Min;Chung, Man-Pyo;Suh, Gee-Young;Kang, Soo-Jung;Kang, Kyeong-Woo;Ahn, Jong-Woon;Lim, Si-Young;Kim, Ho-Joong;Han, Jeung-Ho;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.932-943
    • /
    • 2000
  • Background : Nonspecific interstitial pneumonitis (NSIP) is most likely to be confused with usual interstitial pneumonitis (UIP). Unlike patients witþ UIP, the majority of patients with NSIP have a good prognosis, with most patients improving after treatment with corticosteroids. Therefore it is clinically important to differentiate NSIP from UIP. Up to now, the only means of differentiating these two diseases was by means of surgical lung biopsy. American Thoracic Society (ATS) proposed a clinical diagnostic criteria for UIP to provide assistance to clinicians in its diagnosis without surgical lung biopsy. This study is aimed to investigate whether there were clinical and radiological differences between NSIP and UIP, and the usefulness of ATS clinical diagnostic criteria for UIP in Korea. Methods : We studied 60 patients with UIP and NSIP confirmed by surgical lung biopsy. Clinical manifestations, pulmonary function test, arterial blood gas analysis, bronchoalveolar lavage (BAL), and high resolution computed tomography (HRCT) were evaluated and analyzed by Chi-square test or t-test. The clinical criteria for UIP proposed by ATS were applied to all patients with idiopathic interstitial pneumonia. Results : Forty-two patients with UIP and 18 with NSIP were pathologically identified. Among the 18 patients with NSIP (M : F=1 : 17), the mean age was 55.2$\pm$8.4 (44~73) yr. Among the 42 patients with UIP (M : F=33 : 9), the mean age was 59.5$\pm$7.1 (45~74) yr (p=0.046). Fever was more frequent in NSIP (39%) (p=0.034), but clubbing was frequently observed in UIP (33%) (p=0.023). BAL lymphocytosis was more frequent (23%) (p=0.0001) and CD4/CD8 ratio was lower in NSIP (p=0.045). On HRCT, UIP frequently showed honeycomb appearance (36 of 42 patients) though not in NSIP (p=0.0001). Six of 42 UIP patients (14.3%) met the ATS clinical criteria for IPF, and 3 of 16 NSIP patients (18.8%) met the diagnostic criteria. Conclusion : Being a relatively young female and having short duration of illness, fever, BAL lymphocytosis, low CD4/CD8 ratio with the absence of clubbing and honeycomb appearance in HRCT increase the likelihood of the illness being NSIP. The usefulness of ATS clinical diagnostic criteria for UIP may be low in Korea.

  • PDF

Pulmonary Mycoses in Immunocompromised Hosts (면역기능저하 환자에서 폐진균증에 대한 임상적 고찰)

  • Suh, Gee-Young;Park, Sang-Joon;Kang, Kyeong-Woo;Koh, Young-Min;Kim, Tae-Sung;Chung, Man-Pyo;Kim, Ho-Joong;Han, Jong-Ho;Choi, Dong-Chull;Song, Jae-Hoon;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1199-1213
    • /
    • 1998
  • Background : The number of immunocompromised hosts has been increasing steadily and a new pulmonary infiltrate in these patients is a potentially lethal condition which needs rapid diagnosis and treatment. In this study we sought to examine the clinical manifestations, radiologic findings, and therapeutic outcomes of pulmonary mycoses presenting as a new pulmonary infiltrate in immunocompromised hosts. Method : All cases presenting as a new pulmonary infiltrate in immunocompromised hosts and confirmed to be pulmonary mycoses by pathologic examination or by positive culture from a sterile site between October of 1996 and April of 1998 were included in the study and their chart and radiologic findings were retrospectively reviewed. Results : In all, 14 cases of pulmonary mycoses from 13 patients(male : female ratio = 8 : 5, median age 47 yr) were found. Twelve cases were diagnosed as aspergillosis while two were diagnosed as mucormycosis. Major risk factors for fungal infections were chemotherapy for hematologic malignancy(10 cases) and organ transplant recipients(4 cases). Three cases were receiving empirical amphotericin B at the time of appearance of new lung infiltrates. Cases in the hematologic malignancy group had more prominent symptoms : fever(9/10), cough(6/10), sputum(5/10), dyspnea(4/10), chest pain(5/10). Patients in the organ transplant group had minimal symptoms(p<0.05). On simple chest films, all of the cases presented as single or multiple nodules(6/14) or consolidations(8/14). High resolution computed tomograph showed peri-lesional ground glass opacities(14/14), pleural effusions(5/14), and cavitary changes(7/14). Definitive diagnostic methods were as follows : 10 cases underwent minithoracotomy, 2 underwent video-assisted thoracoscopic surgery, 1 underwent percutaneous needle aspiration and 1 case was diagnosed by culture of abscess fluid. All cases received treatment with amphotericin B with 1 case each being treated with liposomal amphotericin B and itraconazole due to renal toxicity. Lung lesion improved in 12 of 14 patient but 4 patients died before completing therapy. Conclusion : When a new lung infiltrate develops presenting either as a nodule or consolidation in a neutropenic patient with hematologic malignancy or in a transplant recipient, you should always consider pulmonary mycoses as one of the differential diagnosis. By performing aggressive work up and early treatment, we may improve prognosis of these patients.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Scalable Collaborative Filtering Technique based on Adaptive Clustering (적응형 군집화 기반 확장 용이한 협업 필터링 기법)

  • Lee, O-Joun;Hong, Min-Sung;Lee, Won-Jin;Lee, Jae-Dong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.2
    • /
    • pp.73-92
    • /
    • 2014
  • An Adaptive Clustering-based Collaborative Filtering Technique was proposed to solve the fundamental problems of collaborative filtering, such as cold-start problems, scalability problems and data sparsity problems. Previous collaborative filtering techniques were carried out according to the recommendations based on the predicted preference of the user to a particular item using a similar item subset and a similar user subset composed based on the preference of users to items. For this reason, if the density of the user preference matrix is low, the reliability of the recommendation system will decrease rapidly. Therefore, the difficulty of creating a similar item subset and similar user subset will be increased. In addition, as the scale of service increases, the time needed to create a similar item subset and similar user subset increases geometrically, and the response time of the recommendation system is then increased. To solve these problems, this paper suggests a collaborative filtering technique that adapts a condition actively to the model and adopts the concepts of a context-based filtering technique. This technique consists of four major methodologies. First, items are made, the users are clustered according their feature vectors, and an inter-cluster preference between each item cluster and user cluster is then assumed. According to this method, the run-time for creating a similar item subset or user subset can be economized, the reliability of a recommendation system can be made higher than that using only the user preference information for creating a similar item subset or similar user subset, and the cold start problem can be partially solved. Second, recommendations are made using the prior composed item and user clusters and inter-cluster preference between each item cluster and user cluster. In this phase, a list of items is made for users by examining the item clusters in the order of the size of the inter-cluster preference of the user cluster, in which the user belongs, and selecting and ranking the items according to the predicted or recorded user preference information. Using this method, the creation of a recommendation model phase bears the highest load of the recommendation system, and it minimizes the load of the recommendation system in run-time. Therefore, the scalability problem and large scale recommendation system can be performed with collaborative filtering, which is highly reliable. Third, the missing user preference information is predicted using the item and user clusters. Using this method, the problem caused by the low density of the user preference matrix can be mitigated. Existing studies on this used an item-based prediction or user-based prediction. In this paper, Hao Ji's idea, which uses both an item-based prediction and user-based prediction, was improved. The reliability of the recommendation service can be improved by combining the predictive values of both techniques by applying the condition of the recommendation model. By predicting the user preference based on the item or user clusters, the time required to predict the user preference can be reduced, and missing user preference in run-time can be predicted. Fourth, the item and user feature vector can be made to learn the following input of the user feedback. This phase applied normalized user feedback to the item and user feature vector. This method can mitigate the problems caused by the use of the concepts of context-based filtering, such as the item and user feature vector based on the user profile and item properties. The problems with using the item and user feature vector are due to the limitation of quantifying the qualitative features of the items and users. Therefore, the elements of the user and item feature vectors are made to match one to one, and if user feedback to a particular item is obtained, it will be applied to the feature vector using the opposite one. Verification of this method was accomplished by comparing the performance with existing hybrid filtering techniques. Two methods were used for verification: MAE(Mean Absolute Error) and response time. Using MAE, this technique was confirmed to improve the reliability of the recommendation system. Using the response time, this technique was found to be suitable for a large scaled recommendation system. This paper suggested an Adaptive Clustering-based Collaborative Filtering Technique with high reliability and low time complexity, but it had some limitations. This technique focused on reducing the time complexity. Hence, an improvement in reliability was not expected. The next topic will be to improve this technique by rule-based filtering.

Preparation and Characterization of Physicochemical and Sensory Properties of Bread Enriched with Two Types of Wild Grape Extract (제조방법이 다른 두 종류의 머루즙 첨가가 빵의 이화학적 및 관능적 특성에 미치는 영향)

  • Lee, Byung-Yong;Lee, Malp-Eum;O, Jin-Hwan;Kim, Eun-Cho;Surh, Jeong-Hee
    • Korean journal of food and cookery science
    • /
    • v.26 no.5
    • /
    • pp.636-648
    • /
    • 2010
  • Two types of wild grape extracts(WGE) prepared by different methods were added into butter-top bread at different concentrations(0, 5, 10, 15, 20% of water). Then, the resulting breads were analyzed for their physicochemical and sensory properties in order to identify whether or not the WGE-enriched breads were comparable to control bread in terms of qualities and preferences. Wild grape sugar mixture(WGS), which was prepared by osmotic dehydration of wild grape fruits with the same amounts of sugar, presented significantly lower moisture content and titratable acidity as well as higher pH and sugar content compared to wild grape juice(WGJ), which was produced by boiling the fruits in a vacuum jar and squeezing. The pH of the doughs and breads containing WGE tended to decrease with increasing amounts of WGE, and this phenomenon was more appreciable in those containing WGJ than WGS. This was presumably due to the higher contents of tartaric acid in WGJ. For both types of extracts, hardness, gumminess, and chewiness of the doughs decreased with the addition of WGE, nevertheless, which properties were not remained in the resulting breads. This could be partially attributed to the relatively high degree of baking loss and lower pH of the WGE-enriched breads than those of control bread. Contrary to the mechanical analyses, the sensory properties of the breads were dependent on the WGE type. That is, WGJ-enriched bread showed lower consistency and moistness than control bread, which consequently led to relatively lower overall acceptability. However, WGS addition did not adversely affect the sensory properties of the bread. In particular, addition of 5% WGS somewhat improved the physical and sensory qualities of the bread. Thus, WGE-enriched bread could be produced without loss of bread quality when prepared with 5% WGS.