• Title/Summary/Keyword: hemodynamic failure

Search Result 108, Processing Time 0.021 seconds

Catastrophic catecholamine-induced cardiomyopathy rescued by extracorporeal membrane oxygenation in recurrent malignant pheochromocytoma

  • Min, Daniel
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.3
    • /
    • pp.254-259
    • /
    • 2019
  • Pheochromocytoma (PCC) is a rare catecholamine-producing tumor with the incidence in hypertension of 0.1-0.6%. PCC crisis is an endocrine emergency that can lead to hemodynamic disturbance and organ failure such as catecholamine-induced cardiomyopathy. The circulatory collapse caused by it often requires mechanical support. The author reports an unusual case in which a patient who previously underwent surgery for malignant PCC developed catecholamine-induced cardiomyopathy, and successfully recovered using extracorporeal membrane oxygenation.

Retrospective Evaluation for Efficacy and Tolerance of beta-blocker in Heart Failure Patients with Concomitant Diabetes (당뇨를 동반한 심부전 환자에 대한 beta-blocker의 유효성 평가)

  • Jang, Sun-Mi;Kang, Min-Hee;Lim, Sung-Cil;Lee, Jun-Seop;Lee, Myung-Koo
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.2
    • /
    • pp.113-122
    • /
    • 2006
  • Purpose: A retrospective study was performed to assess the efficacy and tolerance of ${\beta}-blocker$ administration in patients with heart failure and diabetes. Method: Records of 164 patients who were treated for the heart failure condition more than a year were studied retrospectively. Patients were divided into 4 groups based on their diabetes(DM) status and the administration of ${\beta}-blockers$ ($DM+{\beta}-blocker$ group: 14, DM w/o ${\beta}-blocker$: 19, No DM + ${\beta}-blocker$: 62, No DM + no ${\beta}-blocker$: 69). All patients had been receiving conventional therapy such as digoxin, ACE-I, ARB, diuretics, nitrates, aspirin, anticoagulants or lipid-lowering agents. The primary endpoints (death and hospital admission) were recorded during 1 year period and hemodynamic factors (HR, LVEF, SBP, DBP) were obtained from all patient groups before and after 12 months of ${\beta}-blocker$ treatment. To evaluate toxicity of ${\beta}-blocker$, SCr, BUN, AST, ALT and Alkaline phosphatase were obtained. Result: There were less death and hospital admission in DM + ${\beta}-blocker$ group than in DM without ${\beta}-blocker$ group (p=0.014). Relative risk of hospital admission for $DM+{\beta}-blocker$ group over no DM group was 1.17. Long term ${\beta}-blocker$ administration was associated with an improvement of heart rate in patients with DM (P< 0.02) with no significant improvement of LVEF, SBP, DBP. in DM patient. In patient without DM, ${\beta}-blocker$ was associated with improvement in LVEF, HR and DBP (P<0.01, P<0.03), but not in SBP. The incidence of toxicity was similar between the four group with no significant difference. Conculsion: Treatment of heart failure patients with ${\beta}-blocker$ appears to be beneficial in terms of hospital admission event and several hemodynamic factors. The toxicities of ${\beta}-blocker$ treatment were not significant and the treatment is generally well-tolerated in most of the heart failure patients.

  • PDF

Acute Hemodynamic Effects of CJ-10513, an Angiotensin IIReceptor Antahonest, in Dog Treated with High Friquency Ventricular Pacing (안지오텐신 ll 수용체 길항약 CJ-10513이 고민도 심실 pacing 천에서의 혈행동태에 미치는 영향)

  • Kim, Young-Hoon;Jeong, Seong-Mok;Shin, Jae-Kyu;Choi, Jae-Mook;Jeong, Seong-Hak;Bae, Hoon;Lee, Gun-Ho;Kim, Je-Hak;An, Yang-Soo
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.199-203
    • /
    • 1998
  • Acute hemodynamic effects of CJ-18513, a non-peptide angiotensin IIreceptor antagonist, were examined in mongrel dogs treated with high frequency ventricular pacing for one week. Rapid ventricular pacing reduced mean blood pressure (mBP), Lvdp/dt and cardiac output (CO), and increased the left ventricular end-diastolic pressure (LVEDP) and pulmonary capillary wedge pressure (PCWP). Continuous infusion of CJ-10513 at doses of 10 and 20$\mu$g/kg/min, respectively, for 30 minutes reduced mBP, LVEDP and myocardial oxygen consumption rate (MVO,) and shifted the cardiac function curve (CO-LVEDP ourve) to the left in this dog model. In conclusion, CJ-10513 decreased the preload and afterload and increased the cardiac function in dogs with pacing-induced heart failure.

  • PDF

A Contrast Nephropathy in a Preterm Infant Following Preoperative Embolization of Giant Sacrococcygeal Teratoma

  • Lee, Byong Sop
    • Childhood Kidney Diseases
    • /
    • v.21 no.1
    • /
    • pp.26-30
    • /
    • 2017
  • Newborn infants with huge and highly vascular sacrococcygeal teratoma (SCT) are frequently subjected to renal hypoperfusion secondary to high-output cardiac failure. Any underlying renal dysfunction is a significant risk factor for the development of contrast-induced nephropathy (CIN). However, reports on CIN in infants are rare. I report here a case of a premature infant born at 28 weeks and 3 days of gestation with a huge SCT who survived preoperative embolization and surgical resection but presented with persistent non-oliguric renal failure that was suggestive of CIN. During radiological intervention, a contrast medium had been administered at about 10 times the manufacturer-recommended dose for pediatric patients. Despite hemodynamic stabilization and normalization of urine output immediately following surgery, the patient's serum creatinine and cystatin-C levels did not return to baseline until 4 months after birth. No signs of reflux nephropathy were observed in follow-up imaging studies. Dosing guidelines for the use of a contrast medium in radiological interventions should be provided for infants or young patients.

Pulmonary Thromboembolectomy of Chronic Pulmonary Thromboembolism (만성 폐전색증의 전색 제거술 치험 -1례 보고-)

  • 문석환
    • Journal of Chest Surgery
    • /
    • v.21 no.5
    • /
    • pp.911-917
    • /
    • 1988
  • Pulmonary thromboembolism originated most commonly from the venous thrombus, especially deep vein thrombus in the leg, which migrated to and occluded the pulmonary vasculatures. The failure of clot lysis and repeated embolic episodes resulted in the hemodynamic compromise -that is- in the increasing in the pulmonary vascular resistance, which would cause the right ventricle failure[Car Pulmonale]. Under the cardiopulmonary bypass, 20 year old male patient was treated successfully by thromboembolectomy of pulmonary thromboembolism with pulmonary hypertension, which originated from the deep vein thrombus in the leg. The results of radiologic studies and clinical evaluations were excellent in that the postoperative lung perfusion scan showed the newly increased perfusion of post-embolectomy territories and in the arterial blood gas finding of 76 from 66[mmHg] in PaO2. The patient was uneventful and discharged on postop. $ 14 days with anticoagulant continued.

  • PDF

Acute Heart Failure after Relief of Massive Pericardial Effusion (대량의 심낭삼출액 제거 후 발생한 급성 심부전)

  • Jung Tae-Eun;Lee Dong-Hyup
    • Journal of Chest Surgery
    • /
    • v.39 no.9 s.266
    • /
    • pp.702-705
    • /
    • 2006
  • Severe left ventricular dysfunction after relief of massive pericardial effusion has been rarely reported. Interventricular volume mismatch, acute distention of the cardiac chambers and interplay of autonomic none system are believed to be the possible causes for ventricular dysfunction. Presenting two patients who had marked decrease in global ventricular systolic function after relief of pericardial tamponade by subxyphoid pericardial window, we recommend gradual removal of pericardial fluid under hemodynamic monitoring, especially in patient with postcardiotomy tamponade.

Mid term experience with CarboMedics Medical Valve (CarboMedics 기계판막의 임상경험)

  • 김기출
    • Journal of Chest Surgery
    • /
    • v.26 no.10
    • /
    • pp.753-760
    • /
    • 1993
  • The CarboMedics valve is a bileaflet prosthesis with excellent hemodynamic characteristics, but the long term surgical experience with this valve, its durability and its biocompatibility are unknown. During a 5 year period from october 1988 to July 1993, 748 prostheses [402 mitral, 261 aortic, 58 tricuspid, 27 pulmonic] were inserted in 552 patients [mean age 40.2 years]. The operative mortality was 6.6% [37/560, 13.2% in age group below 15 years and 5.7% above 15 years]. and the main causes of death were complex congenital malformation and left ventricular failure. Follow up was totaled 1182 patient- years and mean follow up was 28.3 months/patient. No structural failure has been observed. Hemorrhage was the most frequent valve related complication[1.78% / Patient-year]. Embolism occurred at a rate of 0.93% / Patient-year. There were 5 cases of valve thrombosis [0.42% / Patient-year, two fatal]. There occurred 11 late deaths[6 valve related] and 42 valve related complications. Actuarial survival at 5 years is 97.18 0.94% and actuarial complication free survival at 5 years is 89.07 1.54%. In summary, the CarboMedics valve stands for a durable valve substitute, with low valve related complications.

  • PDF

Clinical Experiences of St. Jude Medical Cardiac Valve Replacement (St. Jude Medical valve의 임상적 고찰)

  • 김종원
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.518-525
    • /
    • 1992
  • 50 months experience with St-Jude Medical Cardiac Valve Prosthesis The St. Jude Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism. The data for this study was collected from April 1986 to May 1990, four years period. There were total of 110 patients[female 53, male 58] in this series with 22 isolated aortic valve, 66 isolated mitral valve, 20 double valve, 2 tricuspid valve replacement. The mean follow up time was 23 months. Postoperatively, 77% of cases were in New York Heart Association[NYHA] functional class I, and mild and moderate symptoms[NYHA II ] were present in 20% and there were very few patients remaining in higher functional classifications. In postoperative echocardiographic study showed marked improved cardiac function. The overall early mortality was 5.4% and was higher after double[13.3%] and mitral valve replacement[5.6%] and the late mortality was one case after mitral valve replacement due to endocarditis. The cause of death in early mortality was attributed to heart failure, acute renal failure, sepsis, etc.

  • PDF

Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves (송아지에 이식한 공기구동형 인공심장의 혈역학적 연구)

  • 박표원
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

The Effect of Leaflet Elasticity on the Hydrodynamic Performance of Trileaflet Prosthetic Valves (삼엽인공판막 leaflet 탄성도가 수력학적 성능에 미치는 영향)

  • Seo, J.C.;Rhee, K.H.;Lee, S.H.;Ahn, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.109-112
    • /
    • 1997
  • The Hydrodynamic performance of the trileaflet polymer prosthetic valves depends on the design of the leaflet and the physical properties of the leaflet membrane. In order to study the effect of leaflet membrane elasticity on the hemodynamic performance of trileaflet prosthetic valve, leaflet membranes are manufactured using two different polymers - Biospan and Tecoflex SG-93A. The hemodynamic performance parameters are measured under steady and physiological pulsatile flow, and compared with monoleaflet polymer valve(floating valve) and bileaflet mechanical valve(St. Jude Medical valve). Well designed trileaflet valve shows the lowest mean pressure drop among the tested valves. The trileaflet valves with Biospan membrane show lower pressure drop and back low comparing to those with Tecoflex membrane. More elastic membrane may provide wide opening area during systole and close membrane ree edge contact during diastole. Durability of trileaflet valves are also tested in vitro. Trileaflet valves with non-uniform membrane thickness ail within 17 days because of stress concentration. Trileaflet polymer valves with uniform membrane thickness perform well over 55 days without failure.

  • PDF