• 제목/요약/키워드: helium leak

검색결과 39건 처리시간 0.036초

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental of the Rotaing Cryogenic System)

  • 이창규;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

질량분석기형 누출검출기를 이용한 헬륨투과형 표준 누출 비교 교정 장치 개발 (Development of Comparative Calibration System for Helium Leak Standard by Using Mass Spectrometer Type Leak Detector)

  • 홍승수;임인태;김진태;신용현
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.151-156
    • /
    • 2008
  • 반도체나 디스플레이 제조 등 진공공정의 리크검출에는 질량분석기형(mass spectrometer type) 헬륨 리크검출기(leak detector)가 사용되고 있다. 이 기기를 이용해서 안정된 측정값을 얻기 위해서는 장치 내부에 내장된 투과형(permeation type) 표준리크(standard leak)를 이용해서 자주 spectrometer를 교정해야 한다. 본 연구에서 질량분석기형 리크검출기의 비교교정 장치의 개발과 교정방법에 대한 연구결과를 언급하였다. 따라서 이 기술을 이용하면 질량분석기형 리크검출기를 구비하고 있는 현장에서도 표준리크의 비교교정이 가능하게 된다.

밀폐형 SUS CAN Rotor를 위한 Leak 검사 자동화 시스템 (A Leak Inspection Automation System for Sealed SUS CAN Rotor)

  • 최창민;서수민;신기수;박종원;정연석;유남현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.406-408
    • /
    • 2019
  • 자동차에 사용되는 전동식 워터펌프에 적용되는 모터는 CANNED TYPE의 모터 구조이다. 모터의 구동 부품인 로터는 플라스틱 사출물의 격벽 구조 내에 위치하며, 부동액에 침수되어 있는 상태로 회전을 하게 된다. 플라스틱 사출물 격벽 구조 외부에 Stator가 위치되어 Rotor가 회전이 가능하도록 한다. Rotor의 구성은 Magnet와 Core, Shaft로 구성되며, Magnet와 Core의 경우 부품 특성상 수분 침투에 부식되는 재질이기 때문에 부품의 기밀 유지는 매우 중요하다. 차량에 장착된 상태에서는 120도의 환경조건에서 구동이 가능하여야 하며, 내부압력이 1 Bar 이상의 압력에도 누수가 없어야 한다. 본 논문에서는 이 조건을 만족하여 개발된 전동식 워터펌프의 불량을 검사하기 위하여 헬륨을 이용한 Leak 검사 자동화 시스템을 설계 및 구현하였다.

  • PDF

조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구 (A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test)

  • 김웅기;김수성;이철용;이도연;이정원
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

RF MEMS 스위치 적용을 위한 밀봉성 패키지의 특성 연구 (Characteristic study of hermetic package for RF MEMS switch)

  • 방용승;김종만;김용성;김정무;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1464-1465
    • /
    • 2008
  • In this paper, we compared the mechanical characteristics between LTCC-based RF MEMS packaging structures fabricated using two different types of bonding materials; BCB and gold-tin. The BCB-based packages showed an average shear strength of 32.1 MPa and helium leak rate of $1.76{\times}10^{-8}atm{\cdot}cc/sec$ for a cavity volume of $0.45\times10^{-3}cc$, while the packages bonded by gold-tin layer (80 wt.% gold, 20 wt.% tin) showed an average shear strength of 42.70 MPa and helium leak rate $1.38{\times}10^{-8}atm{\cdot}cc/sec$ for a cavity volume of $1.21{\times}10^{-3}cc$.

  • PDF