• Title/Summary/Keyword: height to width ratio

Search Result 494, Processing Time 0.032 seconds

An Anthropometric and Three-Dimensional Computed Tomographic Evaluation of Two-Point Fixation of Zygomatic Complex Fractures

  • Jo, Taehee;Kim, Junhyung
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.493-499
    • /
    • 2014
  • Background Maintaining stability and restoring the aesthetic appearance are the fundamental goals when managing zygomatic fractures. We aimed to evaluate the stability and anthropometric outcomes of zygomatic fracture patients who underwent two-point fixation involving the infraorbital rim and zygomaticomaxillary buttress via the transconjunctival and gingivobuccal approaches without any skin incisions. Methods We examined 15 zygomatic fracture patients who underwent two-point fixation during a 3-year period. Stability was evaluated using three-dimensional facial bone computed tomography. Superoinferior and anteroposterior displacement of the zygoma was quantified. The aesthetic appearance of the periorbital region was evaluated using indirect anthropometry with standardized clinical photographs. The ratios between the eye fissure height and width, and lower iris coverage ratio were used to evaluate aesthetical changes. The bony displacement and aesthetic ratios were analyzed using Wilcoxon or Friedman tests. The correlation between the preoperative zygoma position and anthropometric values was analyzed. Results The positions of the zygoma were similar to those on the contralateral side at the long-term follow-up. The preoperative anthropometric measurements on the fractured side differed from those on the contralateral side, although these values were close to the normal values at the long-term follow-up. Furthermore, we noted that the anteroposterior displacement strongly positively correlated with the lower iris coverage rate (Spearman's coefficient=0.678, P=0.005). Conclusions Two-point fixation of zygomatic fractures achieved stable outcomes on long-term follow-up, and also appeared to be reliable in restoring the aesthetic appearance of the periorbital region.

Low Temperature Hermetic Packaging using Localized Beating (부분 가열을 이용한 저온 Hermetic 패키징)

  • 심영대;김영일;신규호;좌성훈;문창렬;김용준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1033-1036
    • /
    • 2002
  • Wafer bonding methods such as fusion and anodic bonding suffer from high temperature treatment, long processing time, and possible damage to the micro-scale sensor or actuators. In the localized bonding process, beating was conducted locally while the whole wafer is maintained at a relatively low temperature. But previous research of localized heating has some problems, such as non-uniform soldering due to non-uniform heating and micro crack formation on the glass capsule by thermal stress effect. To address this non-uniformity problem, a new heater configuration is being proposed. By keeping several points on the heater strip at calculated and constant potential, more uniform heating, hence more reliable wafer bonding could be achieved. The proposed scheme has been successfully demonstrated, and the result shows that it will be very useful in hermetic packaging. Less than 0.2 ㎫ contact Pressure were used for bonding with 150 ㎃ current input for 50${\mu}{\textrm}{m}$ width, 2${\mu}{\textrm}{m}$ height and 8mm $\times$ 8mm, 5mm$\times$5mm, 3mm $\times$ 3mm sized phosphorus-doped poly-silicon micro heater. The temperature can be raised at the bonding region to 80$0^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional micro heaters. For gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for gross leak check. The pass ratio of bonded dies was 70%, for conventional localized heating, and 85% for newly developed FP scheme. The bonding strength was more than 30㎫ for FP scheme packaging, which shows that FP scheme can be a good candidate for micro scale hermetic packaging.

  • PDF

Morphometric Study of the Korean Adult Pituitary Glands and the Diaphragma Sellae

  • Ju, Kyo-Sung;Bae, Hack-Gun;Park, Hyung-Ki;Chang, Jae-Chil;Choi, Soon-Kwan;Sim, Ki-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Objective: To investigate the morphometric characteristics of the pituitary gland and diaphragma sellae in Korean adults. Methods: Using the 33 formaline fixed adult cadavers (23 male, 10 female), the measurements were taken at the diaphragma sellae and pituitary gland. The authors investigated the relationship between dura and structures surrounding pituitary gland, morphometric aspects of pituitary gland and stalk, and morphometric aspect of central opening of diaphragma sellae. Results: The boundary between the lateral surface of pituitary gland and the medial wall of cavernous sinus was formed by the thin dural layer and pituitary capsule. The pituitary capsule adherent tightly to the pituitary gland was observed to continue from the diaphragma sellae. Mean width, length, and height of the pituitary gland were 14.3${\pm}$2.1, 7.9${\pm}$1.3, and 6.0${\pm}$0.9 mm in anterior lobes, and 8.7${\pm}$1.7, 2.9${\pm}$1.1, and 5.8${\pm}$1.0 mm in posterior lobes, respectively. Although all dimensions of anterior lobe in female were slightly larger than those in male, statistical significance was noted in only longitudinal dimension. The ratio of posterior lobe to the whole length of pituitary gland was about 27%. The mean thickness of pituitary stalk was 2 mm. The diaphragmal opening was 5 mm or more in 26 (78.8%) of 33 specimen. The opening was round in 60.6% of the specimen, and elliptical oriented in an anterior-posterior or transverse direction in 39.4%. Conclusion: These results provide the safe anatomical knowledge during the transsphenoidal surgery and may be helpful to access the possibility of the development of empty sella syndrome.

A Study on the Body Characteristics of Korean Obese Women (Part I)

  • Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.6
    • /
    • pp.937-954
    • /
    • 2010
  • This study analyzes the body characteristics of Korean obese women using 2004 Size Korea data. For selecting the obesity sample, 7 obesity judgment indices were chosen from previous clothing-related studies. A total of 636 females defined as "obese" by 5 out of 7 indices were selected as subjects for this study. 54 body measurements and obesity judgment indices were used. First, the subjects had a BMI 27.11, R$\ddot{o}$hrer index 1.76, Vervaeck index 104.77, Relative weight 133.00, and WHR 0.90. In the case of the distribution by age groups, the twenties were 6.4% of the entire subjects, the thirties were 18.2%, the forties were 16.4%, the fifties were 37.4%, and the sixties were 21.5%. The result of the ANOVAs (divided into 5 age groups) showed significant differences in 41 measurement items except for bust circumference, waist length front, and all of obesity judgment indices. Second, according to the ANOVAs among stature groups divided by 5cm pitches there are significant differences in all measurements except for bust circumference. The results of the ANOVAs among bust circumference groups divided by 5cm pitches show that significant differences were observed in all measurements except four measurement items (including body rise). According to the ANOVAs among the waist circumference groups divided by 5cm pitches, there are no significant differences in all height measurements and shoulder length, waist to hip length, and crotch length. It is confirmed that stature and bust circumference have a deep relationship with measurements other than waist circumference. Third, as the factor analysis were conducted using 39 measurement items to extract the body characteristics of obese women Factor 1 is "circumference measurements & obesity judgment indices," Factor 2 is "heights & arm-related lengths," and Factor 3 is "size and ratio of waist circumference & hip circumference." Factor 4 was "lengths in upper body," Factor 5 was "back width in upper body," Factor 6 was "side neck point to bust & bust circumference," Factor 7 was "length in lower body & arm circumferences," and Factor 8 was "neck base circumference & front widths in upper body." These 8 factors explained 76.54% of the total variance.

Geomechanical and hydrogeological validation of hydro-mechanical two-way sequential coupling in TOUGH2-FLAC3D linking algorithm with insights into the Mandel, Noordbergum, and Rhade effects

  • Lee, Sungho;Park, Jai-Yong;Kihm, Jung-Hwi;Kim, Jun-Mo
    • Geomechanics and Engineering
    • /
    • v.28 no.5
    • /
    • pp.437-454
    • /
    • 2022
  • The hydro-mechanical (HM) two-way sequential coupling in the TOUGH2-FLAC3D linking algorithm is validated completely and successfully in both M to H and H to M directions, which are initiated by mechanical surface loading for geomechanical validation and hydrological groundwater pumping for hydrogeological validation, respectively. For such complete and successful validation, a TOUGH2-FLAC3D linked numerical model is developed first by adopting the TOUGH2-FLAC3D linking algorithm, which uses the two-way (fixed-stress split) sequential coupling scheme and the implicit backward time stepping method. Two geomechanical and two hydrogeological validation problems are then simulated using the linked numerical model together with basic validation strategies and prerequisites. The second geomechanical and second hydrogeological validation problems are also associated with the Mandel effect and the Noordbergum and Rhade effects, respectively, which are three phenomenally well-known but numerically challenging HM effects. Finally, sequentially coupled numerical solutions are compared with either analytical solutions (verification) or fully coupled numerical solutions (benchmarking). In all the four validation problems, they show almost perfect to extremely or very good agreement. In addition, the second geomechanical validation problem clearly displays the Mandel effect and suggests a proper or minimum geometrical ratio of the height to the width for the rectangular domain to maximize agreement between the numerical and analytical solutions. In the meantime, the second hydrogeological validation problem clearly displays the Noordbergum and Rhade effects and implies that the HM two-way sequential coupling scheme used in the linked numerical model is as rigorous as the HM two-way full coupling scheme used in a fully coupled numerical model.

A study on the Cooking Vessel of Baekje Hanseong Period (백제 한성기 취사용기에 대한 검토 - 심발형토기와 장란형토기를 중심으로 -)

  • Jung, Su Ock
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.112-129
    • /
    • 2011
  • This paper was written to understand, through the types and production techniques, how cooking vessels of Baekje Hanseong period had evolved, - the cooking vessels that were excavated from the historic sites of Baekje Hanseong Period such as Mongchontoseong and Pungnaptoseong of Seoul, the ancient tomb group of Seokchon-dong, and Misari historic site of Hanam. First, the results produced through the analysis of types of these cooking vessels are as followings: as for deep bowls, the maximum body diameter is found on the top of pottery, while as for an egg-shaped pottery, the maximum body diameter is found on the middle height of pottery. However, as for the rim diameter ratio to the neck diameter ratio of pottery, the said two typed potteries were shown to have smaller ones. In consideration of each historic site, as for deep bowls, the ancient tomb group of Seokchon-dong had potteries that had less volumes, were deeper, and had higher maximum body diameters. When it comes to an egg-shaped pottery, Pungnaptoseong had the potteries that were deeper than those of Misari historic site, and their potteries also had the maximum body diameter found on the middle height of pottery, and larger rim diameter ratio to the neck diameter of the pottery. The results produced though the analysis of the production techniques of these cooking vessels are as followings: in the case of deep bowls, as the width of a volume category gets larger, the pottery stamping with an anvil including patterns was more frequently used for pottery production. In this case, simultaneously braid patterns were frequently found on the outer sides of these potteries. In addition, it was found the basal walls of these potteries were thinnest in all typed potteries. This shows there occurred technique transitions according to the time flow. When it comes to an egg-shaped pottery as well, the pottery produced by using an anvil had the thinnest basal wall and its rim diameter ratio to its neck diameter ratio was smaller. Also around the mouth of this pottery, traces were found on its front, the traces formed by the strong rotating power. It is determined these two typed potteries were all produced by using an anvil to have thinner walls. Then, how these potteries were used? In the case of deep bowls, liquid food was put on a hearth or ground to be cooked whereas in the case of an egg-shaped pottery, the pottery was put on a puttumak(kitchen stove) mainly for boiling water. The deep bowls and egg-shaped potteries excavated from the center areas of Baekje Hanseong Period were not clearly determined about when their pastes or firing times were, but as for their production techniques, it was possible to check how they had developed. Moreover, it was determined that in the changing aspects of their production techniques, temporalite is also reflected.

Air Cavity Effects on the Absorbed Dose for 4-, 6- and 10-MV X-ray Beams : Larynx Model (4-, 6-, 10-MV X-선원에서 공기동이 흡수선량에 미치는 효과 : 후두모형)

  • Kim Chang-Seon;Yang Dae-Sik;Kim Chul-Yong;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.393-402
    • /
    • 1997
  • Purpose : When an x-ray beam of small field size is irradiated to target area containing an air cavity, such as larynx, the underdosing effect is observed in the region near the interfaces of air and soft tissue. With a larynx model, air cavity embedded in tissue-equivalent material, this study is intonded for examining Parameters, such as beam quality, field size, and cavity size, to affect the dose distribution near the air cavity. Materials and Methods : Three x-rar beams, 4-, 6- and 10-MV, were employed to Perform a measurement using a 2cm $(width){\times}L$ (length in cm, one side of x-ray field used 2cm (height) air cavity in the simulated larynx. A thin window parallel-plate chamber connected to an electrometer was used for a dosimetry system. A ratio of the dose at various distances from the cavity-tissue interface to the dose at the same points in a homogeneous Phantom (ebservedlexpected ratio, O/E) normalized buildup curves, and ratio of distal surface dose to dose at the maximum buildup depth were examined for various field sizes. Measurement for cavity size effect was performed by varying the height (Z) of the air cavity with the width kept constant for several field sizes. Results : No underdosing effect for 4-MV beam for fields larger than $5cm\times5cm$ was found For both 6- and 10-MV beams, the underdosing portion of the larynx at the distal surface was seen to occur for small fields, $4cm\times4cm\;and\;5cm\times5cm$. The underdosed tissue was increased in its volume with beam energy even for similar surface doses. The relative distal surface dose to maximum dose was changed to 0.99 from 0.95, 0.92, and 0.91 for 4-, 6-, and 10-MV, respectively, with increasing field size, $4cm\times4cm\;to\;8cm\times8cm$, For 6- and 10-MV beams, the dose at the surface of the cavity is measured less than the predicted by about two and three percent. respectively. but decrease was found for 4-MV beam for $5cm\times5cm$ field. For the $4cm\timesL\timesZ$ (height in cm). varying depth from 0.0 to 4.8cm, cavity, O/E> 1.0 was observed regardless of the cavity size for any field larger than about $8cm\times8cm$. Conclusion : The magnitude of underdosing depends on beam energy, field size. and cavity size for the larynx model. Based on the result of the study. caution must be used when a small field of a high quality x-ray beam is irradiated to regions including air cavities. and especially the region where the tumor extends to the surface. Low quality beam. such as. 4-MV x-ray, and larger fields can be used preferably to reduce the risk of underdosing, local failure. In the case of high quality beams such as 6- and 10-MV x-rays, however. an additional boost field is recommended to add for the compensation of the underdosing region when a typically used treatment field. $8cm\times8cm$, is employed.

  • PDF

Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio (전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이)

  • Park, Jong-Wook;Woo, Jae-Hyun;Kim, Byung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.675-684
    • /
    • 2010
  • The reinforced concrete members are designed to fail in flexural to lead ductile fracture. In the building structures, the failure is typically imposed on beams to prevent damages in columns. However, progression of plastic collapse mechanism may ultimately develop, a plastic hinge at the bottem end of the first floor column, which then can be subjected to shear or bond finally due to large axial force and small shear span-to-depth ratio. In this study, 10 RC column specimens failed in shear after flexural yielding was investigated to determine the factors affecting the plastic hinge length. The findings of this study showed that the most effective factor affecting the plastic hinge length was an axial force. As an axial force increase, an axial strain and a ductility ratio were decreased obviously. The test also shows the observed plastic hinge length was about 0.8~1.2d and the this result has difference compared with forward research.

Profiles of Spinal Cord Tumors Removed through a Unilateral Hemilaminectomy

  • Yeo, Dong-Kyu;Im, Soo-Bin;Park, Kwan-Woong;Shin, Dong-Seong;Kim, Bum-Tae;Shin, Won-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.195-200
    • /
    • 2011
  • Objective : To present the profiles of spinal cord tumors that can be removed through a unilateral hemilaminectomy and to demonstrate its usefulness for benign spinal cord tumors that significantly occupy the spinal canal. Methods : From June 2004 to October 2010, 25 spinal cord tumors were approached with unilateral hemilaminectomy. We calculated the cross-sectional occupying ratio (CSOR) of tumor to spinal canal before and after the operations. Results : The locations of the tumors were intradural extramedullary in 20 cases, extradural in 2, and intramedullary in 3. The levels of the tumors were lumbar in 12, thoracic 9, and cervical 4. In all cases, the tumor was removed grossly and totally without damaging spinal cord or roots. The mean height and width of the lesions we195re 17.64 mm (3-47.5) and 12.62 mm (4-32.7), respectively. The mean CSOR was 69.40% (range, 27.8-96.9%). Postoperative neurological status showed improvement in all patients except one whose neurologic deficit remained unchanged. Postoperative spinal stability was preserved during the follow-up period (mean, 21.5 months) in all cases. Tumor recurrence did not develop during the follow-up period. Conclusion : Unilateral hemilaminectomy combined with microsurgical technique provides sufficient space for the removal of diverse spinal cord tumors. The basic profiles of the spinal cord tumors which can be removed through the unilateral hemilaminectomy demonstrate its role for the surgery of the benign spinal cord tumors in various sizes.

The Correction of a Secondary Bilateral Cleft Lip Nasal Deformity Using Refined Open Rhinoplasty with Reverse-U Incision, V-Y Plasty, and Selective Combination with Composite Grafting: Long-term Results

  • Cho, Byung-Chae;Choi, Kang-Young;Lee, Jung-Hun;Yang, Jung-Dug;Chung, Ho-Yun
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.190-197
    • /
    • 2012
  • Background : This article presents long-term outcomes after correcting secondary bilateral cleft lip nasal deformities using a refined reverse-U incision and V-Y plasty or in combination with a composite graft in order to elongate the short columella. Methods : A total of forty-six patients underwent surgery between September 1996 and December 2008. The age of the patients ranged from 3 to 19 years of age. A bilateral reverse-U incision and V-Y plasty were used in 24 patients. A composite graft from the helical root was combined with a bilateral reverse-U incision in the 22 patients who possessed a severely shortened columella. The follow-up period ranged between 2 and 10 years. Results : A total of 32 patients out of 46 were evaluated postoperatively. The average columella length was significantly improved from an average of 3.7 mm preoperatively to 8.5 mm postoperatively. The average ratio of the columella height to the alar base width was 0.18 preoperatively and 0.29 postoperatively. The postoperative basal and lateral views revealed a better shape of the nostrils and columella. The elongated columella, combined with a composite graft, presented good maintenance of the corrected position with no growth disturbance. A composite graft showed color mismatching in several patients. Twenty-six patients demonstrated no alar-columella web deformity and satisfactory symmetry of the nostrils. Four patients experienced a drooping and overhanging of the corrected alar-columella web. Conclusions : A bilateral reverse-U incision with V-Y plasty or in combination with a composite graft was effective in correcting secondary bilateral cleft lip nasal deformity.