• Title/Summary/Keyword: height resolution

Search Result 321, Processing Time 0.024 seconds

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.

Estimation of the Surface Currents using Mean Dynamic Topography and Satellite Altimeter Data in the East Sea (평균역학고도장과 인공위성고도계 자료를 이용한 동해 표층해류 추산)

  • Lee, Sang-Hyun;Byun, Do-Seong;Choi, Byoung-Ju;Lee, Eun-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.4
    • /
    • pp.195-204
    • /
    • 2009
  • In order to estimate sea surface current fields in the East Sea, we examined characteristics of mean dynamic topography (MDT) fields (or mean surface current field, MSC) generated from three different methods. This preliminary investigation evaluates the accuracy of surface currents estimated from satellite-derived sea level anomaly (SLA) data and three MDT fields in the East Sea. AVISO (Archiving, Validation and Interpretation of Satellite Oceanographic data) provides a MDT field derived from satellite observation and numerical models with $0.25^{\circ}$ horizontal resolution. Steric height field relative to 500 dbar from temperature and salinity profiles in the East Sea supplies another MDT field. Trajectory data of surface drifters (ARGOS) in the East Sea for 14 years provide another MSC field. Absolute dynamic topography (ADT) field is calculated by adding SLA to each MDT. Application of geostrophic equation to three different ADT fields yields three surface geostrophic current fields. Comparisons were made between the estimated surface currents from the three different methods and in-situ current measurements from a ship-mounted ADCP (Acoustic Doppler Current Profiler) in the southwestern East Sea in 2005. For offshore areas more than 50 km away from the land, the correlation coefficients (R) between the estimated versus the measured currents range from 0.58 to 0.73, with 17.1 to $21.7\;cm\;s^{-1}$ root mean square deviation (RMSD). For coastal ocean within 50 km from the land, however, R ranges from 0.06 to 0.46 and RMSD ranges from 15.5 to $28.0\;cm\;s^{-1}$. Results from this study reveal that a new approach in producing MDT and SLA is required to improve the accuracy of surface current estimations for the shallow costal zones of the East Sea.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Clinical Significance of MRI Findings During Medical Treatment for Tuberculous Spondylitis (척추염 환자의 약물치료기간 중 추적 검사한 MRI소견 변화의 임상적 중요성)

  • Kim, Dae-Jung;Chung, Tae-Sub;Suh, Sang-Hyun;Kim, Keun-Su;Cho, Yong-Eun;Yoon, Young-Sul;Kim, Sam-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.146-151
    • /
    • 2009
  • Purpose : To evaluate magnetic resonance (MR) imaging features of non-surgically treated tuberculous spondylitis and to evaluate the relationships between these features and clinical outcomes. Materials and Methods : Data from ten patients (male:female=6:4, mean age=45 years) with clinically proven tuberculous spondylitis who were treated nonsurgically over three months were analyzed retrospectively from 2000 to 2007. MRI was performed at least three times for each patient, at baseline, every three or six months, and at the end of treatment. All images were analyzed by two radiologists. Results : The mean follow-up period for the MR examination was 10.1 months (range, 4-17 months). Six patients had clinically complete resolution of tuberculous spondylitis with medication treatment only. Four patients were treated with surgical management alongside medication. All ten patients were divided into two groups by clinical outcome; six patients with complete treatment and four patients with incomplete treatment. In the complete treatment group, follow-up MR findings showed a loss of subligamentous spread of abscesses, decreased size of abscesses, no interval changes in vertebral body heights, and fatty changes in spinal lesions. MR findings in the incomplete treatment group showed bone marrow edema extension to adjacent vertebra, extension of the abscesses, and decreased height of the vertebral bodies. Conclusion : During the nonsurgical management of tuberculous spondylitis, MR imaging may play a role in predicting patient response to antituberculous drug treatment.

  • PDF

A Methodology of Ship Detection Using High-Resolution Satellite Optical Image (고해상도 광학 인공위성 영상을 활용한 선박탐지 방법)

  • Park, Jae-Jin;Oh, Sangwoo;Park, Kyung-Ae;Lee, Min-Sun;Jang, Jae-Cheol;Lee, Moonjin
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • As the international trade increases, vessel traffics around the Korean Peninsula are also increasing. Maritime accidents hence take place more frequently in the southern coast of Korea where many big and small ports are located. Accidents involving ship collision and sinking result in a substantial human and material damage as well as the marine environmental pollution. Therefore, it is necessary to locate the ships quickly when such accidents occur. In this study, we suggest a new ship detection index by comparing and analyzing the reflectivity of each channel of the Korea MultiPurpose SATellite-2 (KOMPSAT-2) images of the area around the Gwangyang Bay. A threshold value of 0.1 is set based on a histogram analysis, and all vessels are detected when compared with RGB composite images. After selecting a relatively large ship as a representative sample, the distribution of spatial reflectivity around the ship is studied. Uniform shadows are detected on the northwest side of the vessel. This indicates that the sun is in the southeast, the azimuth of the actual satellite image is $144.80^{\circ}$, and the azimuth angle of the sun can be estimated using the shadow position. The reflectivity of the shadows is 0.005 lower than the surrounding sea and ship. The shadow height varies with the position of the bow and the stern, perhaps due to the relative heights of the ship deck and the structure. The results of this study can help search technology for missing vessels using optical satellite images in the event of a marine accident around the Korean Peninsula.

Clinical Characteristics and Genetic Analysis of Prader-Willi Syndrome (Prader-Willi 증후군의 임상 양상 및 유전학적 진단에 관한 고찰)

  • Lee, Ji Eun;Moon, Kwang Bin;Hwang, Jong Hee;Kwon, Eun Kyung;Kim, Sun Hee;Kim, Jong Won;Jin, Dong Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1126-1133
    • /
    • 2002
  • Purpose : Prader-Willi syndrome(PWS) is a complex disorder affecting multisystems with characteristic clinical features. Its genetic basis is an expression defect in the paternally derived chromosome 15q11-q13. We analyzed the clinical features and genetic basis of PWS patients for early detection and treatment. Methods : We retrospectively studied 24 patients with PWS in Department of Pediatrics, Samsung Medical Center, from September 1997 to September 2001. We performed cytogenetic and molecular genetic techniques using high resolution GTG banding techniques, fluorescent in situ hybridization and methylation-specific PCR for CpG island of SNRPN gene region. Results : The average birth weight of PWS patients was $2.67{\pm}0.47kg$ and median age at diagnosis was 1.3 years. The average height and weight of PWS patients under one year at diagnostic time were located in a 3-10 percentile relatively, and a rapid weight gain was seen between two and six years. Feeding problems in infancy and neonatal hypotonia were the two most consistently positive major criteria in over 95% of the patients. In 18 of the 24 cases(75%), deletion of chromosome 15q11-q13 was demonstrated and one case among 18 had an unbalanced 14;15 translocation. In four cases without any cytogenetic abnormality, it may be considered as maternal uniparental disomy and the rest showed another findings. Conclusion : We suggest diagnostic testing for PWS in all infants/neonates with unexplained feeding problems and hypotonia. It is necessary for clinically suspicious patients to undergo an early genetic test. As the genetic basis of PWS was heterogenous and complex, further study is required.

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

The Correlation of Dyspnea and Radiologic Quantity in Patients with COPD (만성폐쇄성폐질환 환자에서 호흡곤란과 영상학적 정량과의 상관관계)

  • Jung, Eun Jung;Kim, Yang Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong Hoon;Kim, Do Jin;Park, Choon Sik;Hwang, Jung Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.4
    • /
    • pp.288-294
    • /
    • 2009
  • Background: A lung hyperinflation, or air trapping, caused by expiratory flow-limitation contributes to dyspnea in patients with chronic obstructive pulmonary disease (COPD). Forced expiratory volume in 1 second ($FEV_1$) has served as an important diagnostic measurement of COPD, but does not correlate with patient-centered outcomes such as dyspnea. Therefore, this study was performed to investigate the role of radiologic quantity in evaluating the dyspnea in patients with COPD by measuring lung hyperinflation in chest x-ray and high resolution chest tomography (HRCT). Methods: Fifty patients with COPD were enrolled in this study. Their subjective dyspnea score (modified Borg scale dyspnea index), spirometry, and lung volume were measured. Simultaneous hyperinflations of chest x-ray score ("chest score") and degree of emphysema of HRCT ("HRCT score") were measured. The "chest score" were composed of lung length, retrosternal space width, and height of the arc of the diaphragm and "HRCT score" were composed of severity and extent of emphysema. Results: The mean age of patients was 69 years old and their mean $FEV_1$ was 51.7%. The Borg score significantly correlated with parameters of spirometry and lung volume, including FVC, $FEV_1$, $FEV_1$/FVC, RV, RV/TLC, and DLCO. The Borg score correlated well with "HRCT score", but did not correlate with "chest score". Also, the Borg scale correlates inversely with body mass index. Conclusion: The quantity of emphysema on chest HRCT may serve as an objective marker of dyspnea in patients with COPD.

Global Ocean Data Assimilation and Prediction System in KMA: Description and Assessment (기상청 전지구 해양자료동화시스템(GODAPS): 개요 및 검증)

  • Chang, Pil-Hun;Hwang, Seung-On;Choo, Sung-Ho;Lee, Johan;Lee, Sang-Min;Boo, Kyung-On
    • Atmosphere
    • /
    • v.31 no.2
    • /
    • pp.229-240
    • /
    • 2021
  • The Global Ocean Data Assimilation and Prediction System (GODAPS) in operation at the KMA (Korea Meteorological Administration) is introduced. GODAPS consists of ocean model, ice model, and 3-d variational ocean data assimilation system. GODAPS assimilates conventional and satellite observations for sea surface temperature and height, observations of sea-ice concentration, as well as temperature and salinity profiles for the ocean using a 24-hour data assimilation window. It finally produces ocean analysis fields with a resolution of 0.25 ORCA (tripolar) grid and 75-layer in depth. This analysis is used for providing a boundary condition for the atmospheric model of the KMA Global Seasonal Forecasting System version 5 (GloSea5) in addition to monitoring on the global ocean and ice. For the purpose of evaluating the quality of ocean analysis produced by GODAPS, a one-year data assimilation experiment was performed. Assimilation of global observing system in GODAPS results in producing improved analysis and forecast fields with reduced error in terms of RMSE of innovation and analysis increment. In addition, comparison with an unassimilated experiment shows a mostly positive impact, especially over the region with large oceanic variability.