• Title/Summary/Keyword: height Accuracy

Search Result 739, Processing Time 0.034 seconds

Video Based Pedestrian Height Estimation Using Winer Optimization (위너 최적화 기법을 이용한 영상기반 보행자 키 추정)

  • Jeon, Sang Hee;Song, Jong Kwan;Park, Jang Sik;Yoon, Byung Woo
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.264-270
    • /
    • 2016
  • In this paper, we proposed a method which can detect pedestrians from CCTV video and estimate the height of the detected objects. We separate the foreground using Gaussian mixture model and the pedestrian is detected using the conditions such as the width-height ratio and the size of the candidate objects. In order to obtain the optimal model for estimating the height of pedestrian, we get many training data from the pedestrian whose height is known. Using these training data, we designed optimal Wiener height estimator and used to estimate the height of pedestrians. The height of the pedestrian at various distance is estimated and the accuracy is evaluated. In the experimental results, proposed method shows that it can estimate the height of pedestrian for various positions effectively.

Estimation of Diameter and Height Growth Equations Using Environmental Variables (환경인자를 이용한 직경 및 수고생장 모형 추정)

  • Lee, Sang-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.3
    • /
    • pp.351-356
    • /
    • 2009
  • This study purposed to judge potential possibility of building highly precise empirical model using environmental variables. Environmental variables such as altitude, mean annual rainfall, mean annual temperature and organic matter ratio of soil were added to height and diameter model for Chamaecyparis obtusa, and examined accuracy and residuals of prediction model. Improvement in precision was found for the Gompertz polymorphic height model by including mean temperature and altitude as independent variables, while the Gompertz diameter model with annual rainfall and altitude was showed improvement of precision and accuracy. Comparing the improvement of precision between the model before adding environmental variables and the model after adding them, an improvement or some ratio was obtained though it is not obvious. Therefore, there is enough proof that adding environmental variables, which can be easily acquired relatively when considering the difficulties of measurement and budget, into the model as independent variables would improve the accuracy and precision of growth models.

Impact of Tropospheric Modeling Schemes into Accuracy of Estimated Ellipsoidal Heights by GPS Baseline Processing: Experimental Analysis and Results (GPS 기선해석에 의한 타원체고 추정에서 대류권 오차 보정기법이 정확도에 미치는 영향에 관한 실험적 분석)

  • Lee, Hungkyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Impact of tropospheric correction techniques on accuracy of the GPS (Global Positioning System) derived ellipsoidal heights has been experimentally assessed in this paper. To this end, 247 baselines were constructed from a total of 88 CORS (Continuously Operating Reference Stations) in Korea. The GPS measurements for seven days, acquired from the so-called integrated GNSS (Global Navigation Satellite Systems) data center via internet connection, have been processed by two baseline processing software packages with an application of the empirical models, such as Hopfield, modified Hopfield and Saastamoinen, and the estimation techniques based on the DD (Double-Differenced) measurements and the PPP (Precise Point Positioning) technique; hence a total number of the baseline processed and tested was 8,645. Accuracy and precision of the estimated heights from the various correction schemes were analyzed about baseline lengths and height differences of the testing baselines. Details of these results are summarized with a view to hopefully providing an overall guideline of a suitable selection of the modeling scheme with respect to processing conditions, such as the baseline length and the height differences.

Analysis of the Feasibility of GNSS/Geoid Technology in Determining Orthometric Height in Mountain (산악지 표고결정에 있어서 GNSS/Geoid 기술의 활용가능성 분석)

  • Lee, Suk Bae;Lee, Keun Sang;Lee, Min Kun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.57-65
    • /
    • 2017
  • The purpose of this study is to analyze the feasibility of using Global Navigation Satellite System(GNSS)/Geoid technology in determining orthometric height in mountain. For the study, a test bed was set up in and around Mount Jiri and GNSS surveying were conducted. The orthometric height of 39 benchmarks was determined by applying the EGM2008, KNGeoid13, and KNGeoid14 geoid models and the accuracy was estimated by comparing with the offical Benchmarks orthometric height value issued by National Geographic Information Institute(NGII) and finally, the results were analyzed with the Aerial Photogrammetry Work Regulations. As a result of the study, it was found that the accuracy of the orthometric height determination by GNSS/Geoid technology was ${\pm}7.1cm$ when the KNGeoid14 geoid model was applied. And also, it can be confirmed that it is usable for the less than 1/1000 plotting scales as a vertical reference point for the aerial triangulation in Aerial Photogrammetry.

Feasibility Study of Network-RTK(VRS) Surveying Inside and Outside of Korean CORS Network

  • Kim, Kwang Bae;Du, Chenghao;Lee, Chang Kyung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.47-54
    • /
    • 2016
  • This study aims to analyze the accuracy for feasibility study of Network-RTK(VRS) surveying inside and outside of Korean CORS network. The southwest coast of Korea where some part of mainland and islands are outside of CORS network is chosen as the test area. To evaluate the accuracy of VRS surveying at surveying points, several Unified Control Points (UCPs) inside and outside of Korean CORS network were selected as the points in the test area. The feasibility of VRS surveying was analyzed by investigating the errors related to the location of points inside and outside of CORS network and the difference of 3-dimensional coordinates observed on different date. As the results of this study, the orthometric height errors of points outside of CORS network based on KNGeoid14 were improved about 5.0 cm in RMSE in comparison with KNGeoid13. The height errors of VRS surveying were considered to be less relevant to the results from PDOP and number of satellites (GPS and GLONASS). However, the orthometric errors caused by the geoidal height of KNGeoid and the ellipsoidal height of VRS surveying at points located outside of CORS network need to be addressed carefully for control surveying. When a point surveyed twice on different date, the difference of the ellipsoidal height of the point outside of CORS network was larger than that of the point inside of CORS network.

Study on the 3D Assembly Inspection of Two-Step Variable Valve Lift Modules Using Laser-Vision Technology (레이저 비전을 이용한 2단 가변밸브 리프트 모듈의 3D 조립검사에 대한 연구)

  • Nguyen, Huu-Cuong;Kim, Do-Joong;Lee, Byung-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.10
    • /
    • pp.949-957
    • /
    • 2017
  • A laser-vision-based height measurement system is developed and implemented for the inspection of two-step variable valve lift module assemblies. The proposed laser-vision sensor module is designed based on the principle of laser triangulation. This paper summarizes the work on 3D point cloud data collection and height difference measurements. The configuration of the measurement system and the proposed height measurement algorithm are described and analyzed in detail. Additional measurement experiments on the height differences of valves and lash adjusters of a two-step variable valve lift module were implemented repeatedly to evaluate the accuracy and repeatability of the proposed measurement system. Experimental results show that the proposed laser-vision-based height measurement system achieves high accuracy, repeatability, and stabilization for the inspection of two-step variable valve lift module assemblies.

A Study on Obtaining Tree Data from Green Spaces in Parks Using Unmanned Aerial Vehicle Images: Focusing on Mureung Park in Chuncheon

  • Lee, Do-Hyung;Kil, Sung-Ho;Lee, Su-Been
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.4
    • /
    • pp.441-450
    • /
    • 2021
  • Background and objective: The purpose of study is to analyze the three-dimensional (3D) structure by creating a 3D model for green spaces in a park using unmanned aerial vehicle (UAV) images. Methods: After producing a digital surface model (DSM) and a digital terrain model (DTM) using UAV images taken in Mureung Park in Chuncheon-si, we generated a digital tree height model (DHM). In addition, we used the mean shift algorithm to test the classification accuracy, and obtain accurate tree height and volume measures through field survey. Results: Most of the tree species planted in Mureung Park were Pinus koraiensis, followed by Pinus densiflora, and Zelkova serrata, and most of the shrubs planted were Rhododendron yedoense, followed by Buxus microphylla, and Spiraea prunifolia. The average height of trees measured at the site was 7.8 m, and the average height estimated by the model was 7.5 m, showing a difference of about 0.3 m. As a result of the t-test, there was no significant difference between height values of the field survey data and the model. The estimated green coverage and volume of the study site using the UAV were 5,019 m2 and 14,897 m3, respectively, and the green coverage and volume measured through the field survey were 6,339 m2 and 17,167 m3. It was analyzed that the green coverage showed a difference of about 21% and the volume showed a difference of about 13%. Conclusion: The UAV equipped with RTK (Real-Time Kinematic) and GNSS (Global Navigation Satellite System) modules used in this study could collect information on tree height, green coverage, and volume with relatively high accuracy within a short period of time. This could serve as an alternative to overcome the limitations of time and cost in previous field surveys using remote sensing techniques.

Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D (단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구)

  • Seo, Jeong-Beom;Kim, Dong-Hyeon;Lee, Jeong-Beom
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

A Experimental Study on the Measurement and Estimation of Vehicle Center of Gravity (차량무게중심의 측정 및 추정에 관한 연구)

  • Lee, Myung-Su;Kim, Sang-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.91-99
    • /
    • 2010
  • The center of gravity on vehicle is a fundamentally important point for assessing and measuring the characteristics of vehicle dynamics. Especially, the center of gravity height on vehicles is the closest factor with respect to rollover accidents in a social issue nowadays. In this paper, the center of gravity height in conjunction with vehicle parameters of vehicle weight, driving axle and roof height after measured by vehicle weight and loading location by means of VCGM developed by KATRI with good performance that the accuracy was less than 0.6% and repeatability 0.3% for vehicles being used in the whole world was observed. As a result of study, the location of center of gravity height on vehicle was able to be estimated with only roof height on vehicle.

Analysis of Dynamic Characteristics of Contact Slider Over Practical Disk Surface (실제 디스크 표면 데이터에 대한 접촉 슬라이더의 동적 안정성 해석)

  • 박경수;전정일;박영필;박노철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.160-165
    • /
    • 2002
  • The flying height of contact slider is determined by vertical and pitching motions. This paper performed the computer simulation for flying height change of contact slider. It is changed by many parameters, contact stiffness. contact damping, all bearing stiffness ratio and so on. So computer simulation analysis is performed for knowing for what change of these parameters influences in flying height of contact slider. The practical recording zone surface is gotten by using SPM. In recording zone, flying height is simulated for each parameter. the settling time which the flying height of contact slider is lower than 10nm is analyzed over practical disk surface for changing each parameter. Through these results, the contact slider can be analyzed for more accuracy dynamic characteristics.

  • PDF