• 제목/요약/키워드: heavy liquid

검색결과 313건 처리시간 0.023초

Using Liquid Aluminum Chloride to Reduce Heavy Metals from Animal Wastes (액상염화알루미늄을 이용한 축산 폐기물 속의 중금속 저감 효과)

  • Kim, Chang-Mann;Choi, Jung-Hoon;Choi, In-Hag
    • Journal of Environmental Science International
    • /
    • 제21권3호
    • /
    • pp.377-382
    • /
    • 2012
  • Recent research has demonstrated that treating poultry litter with alum (aluminum sulfate) and aluminum chloride can remove environmental threats (ammonia, soluble phosphorus and odor) posed by litter. However, scientific information available on heavy metal in poultry litter with liquid aluminum chloride is still lacked. The purpose of this study was to investigate the effects of applying liquid aluminum chloride to rice hulls on heavy metals and to provide basic information to producers. Six hundred 0-d-old broiler were assigned to 4 treatments (control, 100 g, 200 g and 300 g of liquid $AlCl_3$/kg of rice hulls, respectively) with 3 replicates of 50 birds. The experimental period lasted for 6 weeks. Liquid $AlCl_3$ was sprayed on the rice hulls surface using a small hand pump. Total Al contents increased (P<0.05) with the increasing levels of liquid $AlCl_3$ levels over time in comparison with control groups. Total Cu and Pb were lowered in all liquid $AlCl_3$ treatments compared with the controls during 6 weeks. Significant differences in all treatments were found for total Cu contents at 2, 3 and 5 weeks and total Pb at 0, 1, 2 and 3 weeks. Total Zn contents decreased with time when compared with controls. However, no significant differences in total Zn contents were observed among all treatments. In light of environmental managements, spraying liquid $AlCl_3$ to rice hulls indicated the significant advantages in reducing heavy metals as well as improving poultry industrial competitiveness.

Fundamental Study on Liquid Phase LPG Injection System for Heavy-Duty Engine (I) (대형엔진용 액상분사식 LPG 연료공급 방식에 대한 기초연구 (1))

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제9권4호
    • /
    • pp.85-91
    • /
    • 2001
  • LPG has been well known as a clean alternative fuel for vehicles. As a fundamental study on liquid phase LPG injection (hereafter LPLI) system application to heavy-duty engine, engine output and combustion performance were investigated with various operating conditions using a single cylinder engine equipped with the LPLI system. Experimental results revealed that no problems were occurred in application of the LPG fuel to heavy-duty engine, and that volumetric efficiency and engine output, by 10% approximately, were increased with the LPLI system. It was resulted from the decrease of the intake manifold temperature through liquid phase LPG fuel injection. These results provided an advantage in the decrease of the exhaust gas temperature, in the control of knocking phenomena, spark timing and compression ratio. The LPLI engine could normally operated under $\lambda$=1.5 or EGR 30% condition. The optimized swirl ratio for the heavy duty LPG engine was found around R_s$ = 2.0.

  • PDF

Is Liquid Water a Hot Quantum Fluid? Anomalies of Water in Thin Liquid Films and in Biological Systems

  • Yoon, Byoung-Jip
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1211-1214
    • /
    • 2003
  • The anomalies that appear at every multiple of 15 ℃ in the viscosity of a thin liquid film of water and of water near solid interfaces are explained in this paper by comparing the thermal wavelength and molecular free volume of water, and quantum numbers are found. The possibility that these anomalies are related to the preferred and/or lethal temperatures of organisms is considered. The toxicity of heavy water (D₂O) can also be explained with this approach.

A negative reactivity feedback driven by induced buoyancy after a temperature transient in lead-cooled fast reactors

  • Arias, Francisco J.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.80-87
    • /
    • 2018
  • Consideration is given to the possibility to use changes in buoyancy as a negative reactivity feedback mechanism during temperature transients in heavy liquid metal fast reactors. It is shown that by the proper use of heavy pellets in the fuel elements, fuel rods could be endowed with a passive self-ejection mechanism and then with a negative feedback. A first estimate of the feasibility of the mechanism is calculated by using a simplified geometry and model. If in addition, a neutron poison pellet is introduced at the bottom of the fuel, then when the fuel element is displaced upward by buoyancy force, the reactivity will be reduced not only by disassembly of the core but also by introducing the neutron poison from the bottom. The use of induced buoyancy opens up the possibility of introducing greater amounts of actinides into the core, as well as providing a palliative solution to the problem of positive coolant temperature reactivity coefficients that could be featured by the heavy liquid metal fast reactors.

Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography (중성자 래디오그래피를 이용한 액체금속 유동장 측정)

  • Cha, Jae-Eun;Saito, Yasushi
    • Journal of the Korean Society of Visualization
    • /
    • 제9권4호
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

Monitoring of Heavy Metals in Agricultural Soils from Consecutive Applications of Commercial Liquid Pig Manure (돈분액비 연용 농경지 중 중금속 함량 모니터링)

  • Go, Woo-Ri;Kim, Ji-Young;Yoo, Ji-Hyock;Lee, Ji-Ho;Kunhikrishnan, Anitha;Lee, Jeong-Mi;Kim, Kye-Hoon;Kim, Doo-Ho;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • 제31권3호
    • /
    • pp.217-223
    • /
    • 2012
  • BACKGROUND: Increase of heavy metals in agricultural ecosystem has become a social issue nationwide as it is related to public health. This study was performed to find out the status and long-term trends with consecutive application with the commercial liquid pig manure in the agricultural fields. METHODS AND RESULTS: Heavy metals including arsenic, cadmium, copper, lead, nickel, and zinc were analyzed in the 41 samples of paddy fields and 54 samples of upland fields consecutively applied with commercial liquid pig manure for 0 to 16 years. Heavy metal accumulation were not increased statistically at the both paddy and upland fields as the consecutive application year of commercial liquid pig manure were increased. However, some of surveyed upland soils exceeded the criteria of cadmium, copper, and zinc designated by the Soil Environmental Conservation Act in Korea. CONCLUSION: Therefore, analysis of heavy metals, specially copper and zinc, in agricultural fields is absolutely necessary before liquid pig manure application to the fields. In addition, heavy metal accumulation in agricultural fields following to the long-term application of liquid pig manure will be monitored periodically considering with bioavailability of copper and zinc to the crops as an essential nutrients.

The Content of Heavy Metals in Manufactured Herbal Medicines (시중에 유통되는 한방생약제제의 중금속 함량)

  • Jung, Dae-Hwa;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • 제17권1호
    • /
    • pp.129-133
    • /
    • 2008
  • This study is an endeavor to evaluate the safety of medicines from heavy metals, prescribed on the basis of herbal medicinal system and oriental medical prescription which are circulated much recently. For that, three globular types, four extract granular types and four liquid types of herbal medicine were bought to compare and analyze the content of heavy metals, such as As, Pb, Cd and Hg, which are harmful to human body. The concentration of Pb was found to be 0.552 ppm in Sachiltang, 2.552 ppm in Anjungjogiwhan and 1.735 ppm in Cheongsangbohwawhan in case of pill type herbal medicine, and liquid type herbal medicine, Maekmundongtang was 0.002 ppm, Galgeuntang was 0.003 ppm, Sangwhatang was 0.004 ppm, 20jeon Daebotang was 0.0185 ppm. And the concentration of Pb was found to be 0.322 ppm in Banhasasimtang, 0.47 ppm in Eungjosan, 0.29 ppm in Yukmijihwangtang, 0.64 ppm in Socheongryongtang in case of granular type. It was found that the liquid types herbal medicines were relatively safer than three pill types of, four granular types of and four liquid types herbal medicines were tested for concentration of heavy metals. It is considered that is required in the stage of raw material treatment, manufacturing and packaging because those herbal medicines are directly taken in and absorbed into human body through the final treatment process.

Concentration of Heavy Metals in Granule, Globular and Liquid types of Herbal Medicines (과립제와 환제 및 현탁액으로 만들어진 생약제제의 중금속 농도)

  • Bae, Jong-Sup;Park, Jong-Pil;Kim, Yong-Ung;Park, Moon-Ki
    • KSBB Journal
    • /
    • 제25권1호
    • /
    • pp.91-96
    • /
    • 2010
  • This study is an endeavor to evaluate the safety of medicines from heavy metals, prescribed on the basis of herbal medicinal system and oriental medical prescription which are circulated much recently. For that, six globular types, six granular types and seven liquid types of herbal medicines were bought to compare and analyze the content of heavy metals, such as As, Pb, Cd and Hg, which are harmful to human body. The concentration of As was 0.219 mg/kg to 1.243 mg/kg, Cd was 0.0282 mg/kg to 0.8481 mg/kg, Pb was 0.9582 mg/kg to 5.233 mg/kg and Hg was 0.001 mg/kg to 0.01 mg/kg in globular and granular types. Otherwise, in the liquid types, As was 0.0123 mg/kg to 0.5024 mg/kg, Cd was 0.0128 mg/kg to 0.0568 mg/kg, Pb was 0.1755 mg/kg to 0.712 mg/kg, and Hg was 0.001 mg/kg to 0.002 mg/kg. It was found that the concentration of heavy metals in liquid types herbal medicines was relatively lower than globular and granular types. It is required to treat, manufacture and manage herbal medicines for safety.

Numerical analysis of the electromagnetic force for design optimization of a rectangular direct current electromagnetic pump

  • Lee, Geun Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.869-876
    • /
    • 2018
  • The force of a direct current (DC) electromagnetic pump used to transport liquid lithium was analyzed to optimize its geometrical and electrical parameters by numerical simulation. In a heavy-ion accelerator, which is being developed in Korea, a liquid lithium film is utilized for its high charge-stripping efficiency for heavy ions of uranium. A DC electromagnetic pump with a flow rate of $6cm^3/s$ and a developed pressure of 1.5 MPa at a temperature of $200^{\circ}C$ was required to circulate the liquid lithium to form liquid lithium films. The current and magnetic flux densities in the flow gap, where a $Sm_2Co_{17}$ permanent magnet was used to generate a magnetic field, were analyzed for the electromagnetic force distribution generated in the pump. The pressure developed by the Lorentz force on the electromagnetic force was calculated by considering the electromotive force and hydraulic pressure drop in the narrow flow channel. The opposite force at the end part due to the magnetic flux density in the opposite direction depended on the pump geometrical parameters such as the pump duct length and width that defines the rectangular channels in the nonhomogeneous distributions of the current and magnetic fields.

The Fundamental Study on Liquid Phase LPG Injection System for Heavy-Duty Engine (II) (대형엔진용 액상분사식 LPG 연료공급방식에 대한 기초연구 (2))

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제9권6호
    • /
    • pp.1-7
    • /
    • 2001
  • Recently, several LPG engines for heavy-duty vehicles have been developed, which can replace some diesel engines that are one of a main source for air pollution in urban area. As a preliminary study on the liquid phase LPG injection (hereafter LPLI) system applicable to a heavy duty LPG engine, the engine output and combustion performance were investigated with various combustion chambers and fuel compositions using a single cylinder engine equipped. Experimental results revealed that ellipse, double ellipse and nebula type combustion chamber made a more advantage in breaking swirl flow into small turbulence scale than bathtub type. Especially, performance of nebula type showed most highest efficiency and engine output under lean mixture conditions. An investigation fur various LPG fuel compositions was also carried out, and revealed that the case with 40% propane and 60% butane shows the lowest efficiency at stoichiometry, however, as the mixture became leaner its efficiency increased and became even higher for 100% propane case.

  • PDF