• Title/Summary/Keyword: heating technology

Search Result 2,988, Processing Time 0.045 seconds

Red Pepper (Capsicum annum) Drying Using Flat-Plate Solar Collectors (평판집열기(平板集熱機)를 이용(利用)한 고추 건조(乾燥)에 관(關)한 연구(硏究))

  • Kim, Dong-Man;Kim, Man-Soo;Chang, Kyu-Seob
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.1
    • /
    • pp.56-64
    • /
    • 1979
  • Two types of fiat-plate collector were designed and constructed for utilizing the solar energy as heating source of red pepper drying. It was performed to investigate the basic factors on using the collectors and the drying effect on various types of red pepper, and the results obtained are summarized as follows. 1. The optimum tilted angles of the collector in Daejeon area were ${\phi}-15^{\circ}$ in summer season and ${\phi}+15^{\circ}$ in winter season when it was adjusted two times per a year: 2. In the conditions during experiment period, average atmospheric temperature and relative humidity were $25.6^{\circ}C$ and 52.6%, respectively, and $42.0^{\circ}C$, 74.2% in the control chamber. The temperature in the drying chamber connected to the water heater was the highest but relative humidity in the chamber connected to the air heater was the lowest among the chambers. 3. The drying velocity of whole red pepper in the chamber connected to the water heater was the fastest as 2.3 times as compared to the whole type on the mat drying followed by air heater and control in decreasing order. The horizontally cut red pepper in the chamber connected to the water heater was dried exceedingly fast among twelve plots. 4. The content of capsaicine as pungent principle and of capsanthine as red pigment in the red pepper were reduced during drying but there were no differences significantly on the drying method, and it could not affect much on the quality of dried product.

  • PDF

Studies on the Utilization of Plant Pigments -II. Stability of Anthocyanin Pigments in Ganges Amaranth- (식물성(植物性) 색소(色素)의 이용(利用)에 관(關)한 연구(硏究) -II. 꽃잎맨드라미(Amaranthus tricolor L.) Anthocyanin색소(色素)의 안정성(安定性)-)

  • Kim, Kwang-Soo;Lee, Sang-Jik;Yoon, Tai-Heon
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.42-49
    • /
    • 1979
  • In order to evaluate the utility of the anthocyanins of Amaranthys tricolor L. as an edible pigment, the present study was undertaken to investigate the effects of pH. temperature, ascorbic acid, sugars and their degradation products, quercetin, thiourea, sodium pyrophosphate and metal ions on the stability of the anthocyanins in the model systems. The results obtained from this study were as follows. 1. The degradation of total anthocyanins was retarded as the pH levels decreased from 8.0 to 1.0. At pH 1.0, however. the initial degradation reaction proceeded faster than at pH 2.0 to 3.0 2. On heating in buffered aqueous solution at $80^{\circ}C$, the total anthocyanin content was higher at pH 2.0 than other pH levels. Increasing the storage temperature accelerated greatly the pigment degradation. In darkness at $40^{\circ}C$, after 10 days, only 19% of the original amount was left, while at $2^{\circ}C$, under the same conditions of storage, approximately 90% of the pigment was retained. The half-life of the pigment, 63.0 days at $2^{\circ}C$, shortened to 1. 7 days at $40^{\circ}C$. 3. An increase in ascorbic arid concentration from 0. 15 to 0.50 mg/ml lowered the anthocyanin retention. 4. There was no significant difference between glucose and fructose in anthocyanin degradation effect. Furfural was more effective than other sugar degradation products, formic acid or levulinic acid in accelerating anthocyanin breakdown. 5. Neither quercetin nor sodium pyrophosphate had a protective effect on the anthocyanins in the presence of ascorbic acid, while, in the systems 0.5 or 1 mg/ml of thiourea with $150{\;}{\mu}g/ml$ of ascorbic acid, the loss of anthocyanins was significantly reduced. 6. Both mercuric and cupric ions in 30 ppm greatly accelerated anthocyanin degradation.

  • PDF

Antimicrobial Activities of Natural Medicinal Herbs on the Food Spoilage or Foodborne Disease Microorganisms (식품부패 및 병원성미생물에 대한 천연약용식물 추출물의 항균효과)

  • Oh, Deog-Hwan;Ham, Seung-Shi;Park, Boo-Kil;Ahn, Cheol;Yu, Jin-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.957-963
    • /
    • 1998
  • Several medicinal herbs, which are nontoxic and have been used widely in traditional folk medicine, were extracted and antimicrobial activity of the extracts was investigated against various foodborne pathogens or food poisioning microorganisms. The ethanol extract of Sansa, Hwangryun, Cheukbaek, and Seokchangpo showed strong antimicrobial activities against Gram postive and Gram negative bacteria, whereas those of Sakunja, Sukjihwang and Baekji had little antimicrobial activities on microorganisms tested. Among medicinal herb extracts, ethanol extract of Coptis chinensis Franch (hwangryun) showed the strongest antimicrobial activity. Antimicrobial activity of ethanol extract of Coptis chinensis Franch was not destroyed by heating at $100^{\circ}C$ for 60 min and at $121^{\circ}C$ for 30 min, which is very stable over heat. The pH effect on minimal inhibitory concentrations (MIC) of the extract of Coptis chinensis Franch indicated that MIC was reduced with increasing the pH value of the medium. The inhibitory effect of partially purified substance from the ethanol extract of Coptis chinensis Franch on the growth of Listeria monocytogenes and Staphylococcus aureus was investigated. Growth of those strains occurred at the concentration of $100{\;}{\mu}g/mL$ and were inhibited at $500{\;}{\mu}g/mL$, whereas those strains was completely inactivated in the presence of $1000{\;}{\mu}g/mL$.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Optimization of Extraction Conditions for Useful Components from Sweet Potato Leaves (고구마 잎의 유용성분 추출조건 최적화)

  • Li, Meishan;Jang, Gwi Yeong;Lee, Sang Hoon;Kim, Sung Tae;Lee, Ji Hyun;Hwang, Se Gu;Sin, Hyun Man;Kim, Hong Sig;Kang, Tae Su;Jeong, Heon Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1749-1756
    • /
    • 2014
  • This study was performed to establish extraction conditions for useful components from sweet potato leaves. Extraction conditions were heating temperature ($40{\sim}60^{\circ}C$), ratio of solvent to sample (10~30 mL/g), and ethanol concentrations (50~90%). The maximum lutein content was $381.88{\mu}g/g$ under the following conditions: 81.23% ethanol concentration, $46.75^{\circ}C$ temperature, and 25.78 mL/g ratio of solvent. The maximum total polyphenol content was 58.44 mg GAE/g under 67.0%, $53.90^{\circ}C$, and 29.10 mL/g, whereas maximum total chlorophyll content was 769.14 mg/100 g under 93.10%, $69.90^{\circ}C$, and 25.98 mL/g, respectively. The highest antioxidant activity of electron-donating ability ($IC_{50}$) was 0.582 mg/mL under 64.56%, $54.63^{\circ}C$, and 19.57 mL/g, whereas total antioxidant activity was 32.54 mg AA eq/g under 64.42%, $44.51^{\circ}C$, and 26.01 mL/g, respectively. Under these conditions, experimental data matched well with the predicted data. Consequently, the present study was carried out to simulate and optimize sweet potato leaves for useful component extraction.

Comparison of Boiling Point and Distillaiion Ranige, Melting Range, and Identification Methods of Various Organizations on Synthetic Food Additives (식품첨가물에 대한 여러 기관의 비점 및 유분측정법, 융점측정법 및 확인시험법 비교)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Jang Young-Mi;Hong Ki-Hyoung;Park Sung-Kwan;Kwon Yong-Kwan;Park Jae-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.134-140
    • /
    • 2005
  • Boiling point and distillation range, melting range, and identification methods in general test method of Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA on chemical food additives were compared. Boiling point of propylene glycol was indicated as boiling point in Korea, distillate in Japan, distillation range in JECFA and USA, and its value was up to the standard. Distillation range of propionic acid was indicated as distillate in Korea and Japan, distillation range in JECFA and USA, and its value was up to the standard. There is no standard on distillation range of isopropyl alcohol in Japanese method. Test method of melting range on synthetic food additives was identical in all organizations, and there are 28 items to which this test method applies in Korean Food Additives Code. The standards on molting range of D-mannitol were different in various organizations, and in USA method there are no standards to which L-ascorbic acid, calciferol, and fumaric acid apply. Synthetic food additives performing the identification test were 251 items in Korean Food Additives Code, but there are no items to which manganese, glycerophosphate, bromate, thiosulfate, and bromide apply. Calcium benzoate was dissolved by heating in benzoate test and we could not identify the citrate in ferric citrate by method (2) of Korea and Japan. Identification test methods for ammonium, lactate, magnesium, copper, sulfate, phosphate, and zinc were identical in all organizations, and these could be identifed by current identification methods.

Manufacture of the vol-oxidizer with a capacity of 20 kg HM/batch in $UO_2$ pellets using a design model (설계 모델을 이용한 $UO_2$ 펠릿 20 kg HM/batch용 분말화 장치 제작)

  • Kim Young-Hwan;Yoon Ji-Sup;Jung Jae-Hoo;Hong Dong-Hee;Uhm Jae-Beop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.255-263
    • /
    • 2006
  • Vol-oxidizer is a device to convert $UO_2$ pellets into $U_3O_8$ powder and to feed a homogeneous powder into a Metal Conversion Reactor in the ACP(Advanced Spent Fuel Conditioning Process). In this paper, we propose a design model of the vol-oxidizer, develop the new vol-oxidizer with a capacity of 20 kg HM/batch in $UO_2$ pellets, and conduct a verification for the device. Design considerations include the internal structure, the capacity, the heating position of the device, and the size. The dimensions of the new vol-oxidizer are decided by the design model. We determine a permeability test of the $U_3O_8$ measuring the temperature distribution, and the volume of $UO_2$ and $U_3O_8$. We manufactured the new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets, and then analyzed the characteristics of the $U_3O_8$ powder for the verification. The experimental results show that the permeability of the $U_3O_8$ throughout mesh enhance more than old vol-oxidizer, the oxidation time takes only 8 hours when compared with the 13 hours of the old device, and the average distribution of particle size is $40{\mu}m$. The capacities of new vol-oxidizer for a 20 kg HM/batch in $UO_2$ pellets were agree well with the predictions of design model.

  • PDF

Coupled T-H-M Processes Calculations in KENTEX Facility Used for Validation Test of a HLW Disposal System (고준위 방사성 폐기물 처분 시스템 실증 실험용 KENTEX 장치에서의 열-수리-역학 연동현상 해석)

  • Park Jeong-Hwa;Lee Jae-Owan;Kwon Sang-Ki;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.117-131
    • /
    • 2006
  • A coupled T-H-M(Thermo-Hydro-Mechanical) analysis was carried out for KENTEX (KAERI Engineering-scale T-H-M Experiment for Engineered Barrier System), which is a facility for validating the coupled T-H-M behavior in the engineered barrier system of the Korean reference HLW(high-level waste) disposal system. The changes of temperature, water saturation, and stress were estimated based on the coupled T-H-M analysis, and the influence of the types of mechanical constitutive material laws was investigated by using elastic model, poroelastic model, and poroelastic-plastic model. The analysis was done using ABAQUS, which is a commercial finite element code for general purposes. From the analysis, it was observed that the temperature in the bentonite increased sharply for a couple of days after heating the heater and then slowly increased to a constant value. The temperatures at all locations were nearly at a steady state after about 37.5 days. In the steady state, the temperature was maintained at $90^{\circ}C$ at the interface between the heater and the bentonite and at about $70^{\circ}C$ at the interface between the bentonite and the confining cylinder. The variation of the water saturation with time in bentonite was almost same independent of the material laws used in the coupled T-H-M processes. By comparing the saturation change of T-H-M and that of H-M(Hydro-Mechanical) processes using elastic and poroelastic material mod31 respectively, it was found that the degree of saturation near the heater from T-H-M calculation was higher than that from the coupled H-M calculation mainly because of the thermal flux, which seemed to speed up the saturation. The stresses in three cases with different material laws were increased with time. By comparing the stress change in H-M calculation using poroelasetic and poroelasetic-plastic model, it was possible to conclude that the influence of saturation on the stress change is higher than the influence of temperature. It is, therefore, recommended to use a material law, which can model the elastic-plastic behavior of buffer, since the coupled T-H-M processes in buffer is affected by the variation of void ratio, thermal expansion, as well as swelling pressure.

  • PDF

The Electron Trap Analysis in Thermoluminescent LiF Crystal

  • Park, Dae-Yoon;Ko, Chung-Duck;Lee, Sang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.214-222
    • /
    • 1972
  • In the optic,11 grade LiF crystal, the electron traps corresponding to the thermoluminescence(abbreviated to TL) glow peak develop as irradiation dose is increased. Originally the electron trap of the crystal has two levels but as the dose reaches to the order of 10$^4$rontgen, it attains five levels as observed in the TL glow curves. The five trap depths are determined from the glow peak temperatures for two different heating rates, $\theta$=6.6$^{\circ}C$/sec and 3.4$^{\circ}C$/sec. The electron trap depths have the following values E$_1$=0.79 eV, E$_2$=0.93 eV, E$_3$=1.02 eV, E$_4$=1.35 eV, E$_{5}$=1.69eV. The special feature of thermoluminescence of optical grade LiF is that the traps, except E$_1$and E$_2$corresponding to 12$0^{\circ}C$ glow peak and 15$0^{\circ}C$ glow peak for $\theta$=6.6$^{\circ}C$/sec, have severe thermal instability, namely E$_3$, E$_4$and E$_{5}$ levels disappear during bleaching process. These defects in the optical grade LiF crystal seem annealed out during the course of TL measurement. The fresh or long time unused LiF(Mg) crystal shows only two glow peaks at 17$0^{\circ}C$ and 23$0^{\circ}C$ for $\theta$=6.6$^{\circ}C$/sec, but upon sensitization with r-ray irradiation, it converts to the six glow peak state. The four electron traps, E$_1$, E$_2$, E$_3$, and E$_{6}$ created by r-ray irradiation and corresponding to the glow peaks at T=10$0^{\circ}C$ 13$0^{\circ}C$, 15$0^{\circ}C$ and 29$0^{\circ}C$ are stable and not easily annealed out thermally, The sensitization essentially required to LiF(Mg) dosimeter is to give the crystal the stable six levels in the electron trap. In optical grade LiF, the plot between logarithm of total TL output versus logarithm of r-ray dose gives more supra-linear feature than that of LiF(Mg). However, if one takes the height of 12$0^{\circ}C$ glow peak(S=6.6$^{\circ}C$/sec), instead of the total TL output, the curve becomes close to that of LiF(Mg).

  • PDF