• Title/Summary/Keyword: heating space

Search Result 675, Processing Time 0.03 seconds

A study on the Changes in form and spatial uses of Urban Hanok in Bukchon, Seoul (서울 북촌한옥의 변화양상에 관한 연구 - 북촌 가꾸기 사업에 따른 2002~2007 한옥 대수선 사례를 대상으로 -)

  • Song, In-Ho;Kim, Young-Soo;Cho, Eun-Joo
    • Journal of architectural history
    • /
    • v.18 no.2
    • /
    • pp.47-63
    • /
    • 2009
  • This study focused on changes in form and spatial uses of Urban Hanok in Bukchon, Seoul. There are 10 representative cases which have been renovated through the policy of 'Preservation & Regeneration of Bukchon' by Seoul metropolitan government and other experts. Changes in form and spatial uses of Urban Hanok in Buckon are as follows. First, Changes of scale. Trough removing extension parts, facade of renovated Hanoks are 'transformed' into recovering their identity. Using basements or lofts, intensive application of spaces is transformation which promotes the vitality of Hanoks. Second, changes of space organization. As Hanok changes its function from residence to commercial or cultural use, il a1so changes space character or reorganizes space organization. It is important that deciding function of Hanok has to adjust its scale and organization. Third, changes of construction performance. Through introducing new material and constructing method, performance of wall has been changed respecting its wooden structure and interior-exterior figure. However, technical studies must back it up not to destroy its value of eco-friendly architecture. Fourth, changes of facility systems, like floor heating system. They changes floor level of Hanok equally, and then sections of Hanok have became simple. Furthermore, inserting new facility space, such as boiler room, stand-up kitchen, bathroom and toilet, organization of space also changed. It is necessary that wise alternative proposal through the method of transformation or mutation must be presented. These four changes can be classification into method of 'transformation' and 'mutation'. Changes of scale are method of transformation and changes of space organization are method of mutation. Also, while changes of construction performance are mutation, changes of facility systems are transformation. Recently, as price of lots have been increased, a lot of Hanoks have been commercialized. Thc commercial energy threat 'the identity of Bukchon as residential area'. From now on, to operate 'identity' and 'vitality' complementary, it is necessary to make up for the preservation policy of Hanok and consolidate renovating standards of Hanok which correspond to character of particular region and building usage.

  • PDF

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Modeling and validation of a parabolic solar collector with a heat pipe absorber

  • Ismail, Kamal A.R.;Zanardi, Mauricio A.;Lino, Fatima A.M.
    • Advances in Energy Research
    • /
    • v.4 no.4
    • /
    • pp.299-323
    • /
    • 2016
  • Cylindrical parabolic solar concentrators of small concentration ratio are attractive options for working temperatures around $120^{\circ}C$. The heat gained can be utilized in many applications such as air conditioning, space heating, heating water and many others. These collectors can be easily manufactured and do not need to track the sun continuously. Using a heat pipe as a solar absorber makes the system more compact and easy to install. This study is devoted to modeling a system of cylindrical parabolic solar concentrators of small concentration ratio (around 5) fitted with a heat pipe absorber with a porous wick. The heat pipe is surrounded by evacuated glass tube to reduce thermal losses from the heat pipe. The liquid and vapor flow equations, energy equation, the internal and external boundary conditions were taken into consideration. The system of equations was solved and the numerical results were validated against available experimental and numerical results. The validated heat pipe model was inserted in an evacuated transparent glass tube as the absorber of the cylindrical parabolic collector. A calculation procedure was developed for the system, a computer program was developed and tested and numerical simulations were realized for the whole system. An experimental solar collector of small concentration, fitted with evacuated tube heat pipe absorber was constructed and instrumented. Experiments were realized with the concentrator axis along the E-W direction. Results of the instantaneous efficiency and heat gain were compared with numerical simulations realized under the same conditions and reasonably good agreement was found.

The Individual Heat-recovery ventilation system of Residential Buildings (주거용 건물의 개별 환기시스템 필요성에 관한 연구)

  • Shin, U-Cheul;Lee, Wang-Je;Yoon, Jong-Ho;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

A STUDY OF LYNDS 1299 DARK CLOUD

  • RYU OK-KYUNGI;LEE YOUNGUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.161-171
    • /
    • 1998
  • We have mapped about 1.5 square degree regions of Lynds 1299, a well isolated dark cloud in the Outer Galaxy (l = $122^{\circ}$, b = $-7^{\circ}$), in the J = 1- 0 transition of $^{12}CO$ and $^{13}CO$ with the 13.7 m radio telescope at Taeduk Radio Astronomy Observatory (TRAO). We found that there are two velocity components in the molecular emission, at $V_{LSR} = -52 km S^{-1}$ (Cloud A) and -8.8 km $s^{-1}$ (Cloud B), respectively. We have derived physical parameters of two molecular clouds and discussed three different mass estimate techniques. We found that there are large discrepancies between the virial and LTE mass estimates for both clouds. The large virial mass estimate reflects the fact that both are not gravitationally bound. We adopt the mass of $5.6 {\times}10^3 \;M{\bigodot}$ for Cloud A and $1.2{\times}10^3 \;M{\bigodot}$) for Cloud B using conversion factor. Cloud A is found to be associated with a localized star forming site, and its morphology is well matching with that of far-infrared (FIR) dust emission. It shows a clear ring structure with an obvious velocity gradient. We suggest that it may be a remnant cloud from a past episode of massive star formation. Cloud B is found to be unrelated to Cloud A (d = 800 pc) and has no specific velocity structure. The average dust color temperature of the uncontaminated portion of Cloud A is estimated to be 24$\~$27.4 K. The low dust temperature may imply that there is no additional internal heating source within the cloud. The heating of the cloud is probably dominated by the interstellar radiation field except the region directly associated with the new-born B5 star. Overall, the dust properties of Cloud A are similar to those of normal dark cloud even though it does have star forming activity.

  • PDF

A Study on the Characteristic of Energy Consumption in the Super High-rise Mixed-use Housing (초고층 주상복합 아파트의 에너지 소비특성에 관한 연구)

  • Lee, Byunghee;Lee, Jaehyuk;Je, Heaseong;Kang, Dongho
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.63-69
    • /
    • 2010
  • Recently, by the increase of demand on Super High-rise mixed-use housing and it's advanced quality, the interest on it has been raised socially. In accordance with it, the matter of resident's health and energy efficiency has been controversial in terms of living in super high-rise housing. This study started from the idea that it is necessary to have an objective data which that has many residents in narrow space with high density. The purpose of this study are as follows; Firstly, with the quantitative data analysis on energy, it will confirm the objective information on the unclear negative idea of super high-rise mixed-use housing. Secondly, it will establish the fundamental data on the energy of super high-rise mixed-use housing by examining the characteristic of energy consumption of the complex which was built more than 5 years ago. There are 4 methods of this study. Firstly, it follows the steps of theoretical view, and defines concept to study on the characteristic of super high-rise mixed-use housing. Secondly, referring to the previous study, it provides better understanding on th stream of this research and the limit as well to guide the direction in terms of energy consumption. Thirdly, it evaluates the characteristic of monthly consumption by researching the use of electricity energy and heating energy of super high-rise mixed-use housing. The major conclusions of this study are as follows; Firstly, the heating use of apartment complex is same, which is not influenced by the type of the building. Secondly, the electricity use of super high-rise mixed-use housing is from 1,2 to 1.5 as high as the normal apartment.

The economic benefit of combustible waste into energy: A contingent valuation study (Fe3C12 식각을 이용한 콘덴싱 보일러 잠열 열교환기의 응축 열전달 촉진)

  • Jang, J.H.;Ahn, J.;Shin, D.H.;Chung, T.Y.
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.307-311
    • /
    • 2013
  • Heating and hot water has accounted for 68% of Korea's household energy usage. Boiler makes up the bulk of the heating and hot water production. Hence a highly efficient boiler is needed in order to reduce energy consumption. A condensing boiler that recovers latent heat is known to be highly efficient. However, it is expensive and takes more space to necessitate research for improvement. In the present study, we investigated condensation heat transfer of a surface roughened by etching treatment. The etched plate showed 9.2% increase in heat transfer compared to original plate.

An Experimental Study on Thermal Damage and Spalling of Concrete Lining in Tunnel Fire (터널화재시 콘크리트 라이닝의 폭렬 및 화재손상에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Kyung-Suk;Lee, Jae-Sung;Kwan, Ki-Hyuk
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.110-120
    • /
    • 2009
  • In tunnel, though the frequency of fire occurrence is relatively lower than other structures, the characteristics of sealed space tends to cause the temperature to rapidly rise to more than $1000^{\circ}C$ within 5minutes after fire, which might eventually lead to a large fire that usually results in a loss of lives and the damage to the properties, not to mention a huge cost necessary for repair and maintenance after fire. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F 2257-1. Referring to tunnel fire scenarios, it clarified the heat transfer characteristics of concrete PC panel lining depending on fire intensity (ISO, $1^{\circ}C$/SEC, MHC, RWS), and to identify the range of thermal damage, the evaluation was carried out using ITA standard. As a result, 30mm under ISO fire condition, 20mm under $1^{\circ}C$/SEC, 100mm under MHC and 50mm under RWS were measured. And when it comes to spalling, 30mm was measured under RWS and MHC.

A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment (지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰)

  • Jo, Yun-Ju;Lee, Jin-Yong;Lim, Soo-Young;Hong, Gyeong-Pyo
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.22-31
    • /
    • 2009
  • Recently use of renewable energies such as geothermal energy for space heating and cooling is increasing in Korea due to energy crisis and global warming. Ground source heat pump (GSHP) is known as one of the most environment-friendly HVAC (heating, ventilation and air-conditioning) systems in the world. However, some potential effects caused installation and operation of the GSHP systems on soil and groundwater environment are reported. The potential effects are closely related with inappropriate installation, operation and closure of the GSHP systems. In this paper, possible effects of the GSHPs on soil and groundwater environments are reviewed.

A Comparative Study on the Architetural Characteristics of Traditional Korean-Chinese and Chinese Dwellings of Sujoenchon Village in Jilin Province of Northeast China (중국(中國) 길림성(吉林省) 수전촌(水田村)의 조선족(朝鮮族) 주거(住居)와 한족(漢族) 주거(住居)의 비교(比較))

  • Lee, sang-hae
    • Korean Journal of Heritage: History & Science
    • /
    • v.34
    • /
    • pp.138-171
    • /
    • 2001
  • This paper, based on the filed survey conducted from August 14 to 21, 2000, examines the architectural characteristics of traditional dwellings of Sujeonchon(수전촌, 水田村) village. Sujeonchon village is located on the northen slope of Changbaishan Mt., Andohyun(안도현, 安圖縣) of jilin Province(吉林省), a province in the northeastern region of China. The village was established between late 1940's and early 1950's by the Korean-Chinese. Later on, some of the Korean-Chinese residents moved out of the village and presently, the residents are composed of both the Korean-Chinese and the Chinese consisting about fifty-fifty. Since the cultural background and the living custom are different from each other ethnic group, that is, the Korean-Chinese and the Chinese, their dwellings reveal some differences between them. Through the study, the architectural characteristics and distinctions of the Korean-Chinese and Chinese dwellings are found and summarized as follows: 1.The way of building layout is different between them: the Chinese mainly follows the north-south direction of building layout, while the Korean-Chinese considers the surrounding environmental condition. 2.The floor level of kitchen is different between them: that of the Chinese house is same as the outdoor earth level, while that of the Korean-Chinese is lower than the outdoor level. 3.The way of providing the kitchen space is different between them: the kitchen of the Chinese house is consist of one separate room, while that of the Korean-Chinese is open to the living area. 4.The way of heating system is different between them: the Chinese house has kang only at the sleeping area, while the Korean-Chinese install whole under-floor heating of gudeul in the living area. 5.The attitude to the way of building is different between them: the Chinese are easily adapt to the new building materials and construction method, while the Korean-Chinese are showing strong attachment to the traditional way of building. 6.The houses of the Chinese and the Korean-Chinese have their own traditional ornaments and talismans on and in the building.