• 제목/요약/키워드: heating space

검색결과 675건 처리시간 0.03초

무전극 형광램프의 전자계 방사 특성 (Electromagnetic Radiation Properties of Electrodeless Fluorescent Lamps)

  • 이종찬;박대희;김광수;함훈;박성목
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.931-934
    • /
    • 2002
  • In recent year there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of Electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life of Electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 100,000 hours. In this paper, the Electromagnetic emitting properties were presented by simulation software operated at 2.65MHz and some specific conditions.

  • PDF

온돌난방공간(溫突暖房空間)의 내표면(內表面) 대류열전달특성(對流熱傳達特性)에 관(關)한 연구(硏究) (Convection Heat-Transfer Characteristics of Ondol-Heated Room)

  • 손장열;안병욱
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.376-385
    • /
    • 1991
  • The purpose of this paper is to propose basic data on convection heat-transfer coefficients in Ondol-heated room. Surface temperatures and several temperatures around each inside surface of wall, floor and ceiling composed of heating room are measured vertically in Ondol-heated model rooms, and the vertical temperature profiles could be expressed by nonlinear equation models. Also, the convection heat transfer phenomena are analysed from the nonlinear equation models. In the results, the convection heat-transfer coefficients of Ondol heated space are suggested by the term of temperature difference between each wall surface and room air temperature and by the relationship between Nusselt number and Rayleigh number of dimensionless numbers.

  • PDF

Various Thermodynamic Factors in Designing Nanostructured Materials from Block Copolymers

  • Cho, Jun-Han
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.207-208
    • /
    • 2006
  • Here, we discuss various thermodynamic factors that affect the design of nanomaterials based on block copolymers. It is well known that the ordering behavior is determined by composition, chain size N, and the ubiquitous Flory. However, the recent discovery of ordering upon heating, immisibility loops, and baroplasticity addresses a clear need for further microscopic interpretation of such. in order to help to design nanomaterials at aimed purposes. Employing a perturbed hard sphere chain model, the molecular factors such as self and cross-interactions, free space distribution, and directional interactions are incorporated in. It is shown that not only typical ordering phenomena, but also the recent observations just mentioned are all described through this unified way.

  • PDF

Effects of experimental conditions on synthesis of titanium carbide crystallites

  • Choi, Jeong-Gil
    • 한국결정성장학회지
    • /
    • 제20권2호
    • /
    • pp.80-84
    • /
    • 2010
  • The temperature-programmed reduction of titanium oxide ($TiO_2$) with pure $CH_4$ was used for the preparation of titanium carbide crystallites. The synthesized materials had the different surface areas, indicating that the structural properties of these materials were strong functions of two different heating rates and space velocity employed. The titanium carbide crystallites were active for $NH_3$ decomposition. Since the reactivity varied with changes in the particle size, ammonia decomposition reactivity over the titanium carbides crystallites appeared to be related to the different active species. The reactivities of titanium carbide crystallites were two and three times lower than those of the vanadium and molybdenum carbide crystallites, respectively. These results suggested that the difference in activities might be related to the degree of electron transfer between metals and carbon.

아동보호시설의 거주실태 및 개선방향을 위한 조사연구 (A Study on the Living Condition and Improvements of Children Shelters)

  • 유수훈
    • 교육시설
    • /
    • 제14권1호
    • /
    • pp.23-32
    • /
    • 2007
  • The purpose of this study is to suggest of facilities improvement and plan at children shelters. To this purpose, the researcher visited and interviewed users of three children shelters. To achieve a concrete goal of the study, (1) property room size per admitted children, (2) space satisfaction as bedroom, living room in a establishment, (3) facilities satisfaction as corridor, sanitation fixture. furniture (4) environment satisfaction as electricity, cooling and heating, ventilation, (5) exterior satisfaction as building image, color, landscape was analysed by interviewing. Based on the results of the analysis, a improvement for children shelters was presented.

반복제어법을 이용한 소각장 NOx 저감용 SCR 시스템의 제어 (Control of SCR System for NOx Reduction in a Refuse Incineration Plant Using Repetitive Control Method)

  • 김인규;여태경;김환성;김상봉
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2762-2770
    • /
    • 2000
  • The refuse incineration plant has an important role in saving the combustion energy for local heating system. But harmful combustion gas(NOx etc.) leads to some serious environmental problem. To reduce the gas, a SCR(Selective Catalytic Reduction)system is installed and it is controlled by adjusting the flow of ammonia gas(NH3) . In this paper, we apply a repetitive control method to reduce NOx by adjusting the flow of ammonia gas for SCR system in a refuse incineration plant which is located in Haeundae, Pusan, Firstly, we analyze the inlet NOx period by FFt method, and verify its periodic variations. Secondly, we design a repetitive control system by using state space model method. Lastly, the effectiveness of repetitive control system is shown by comparing to a conventional PID control in simulation and experimental results.

도시계획단계의 에너지 수요예측 방안에 관한 연구 (A Study on Urban Energy Consumption Estimation on the Urban Planning Stage)

  • 여인애;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.506-510
    • /
    • 2012
  • This study suggested an improved algorithm of urban energy consumption estimation on the urban planning stage which concerns calculation accuracy. The results are as follows. (1) Urban energy consumption was estimated and managed per unit space using E-GIS DB which contains facility information per mesh. (2) Urban energy consumption was reflected by the urban facility classified and standardized by the characteristics of energy use. (3) Calculation accuracy of energy consumption was approached by separately suggested as summer algorithm reflecting urban heat island on summer energy use and winter algorithm reflecting heating system normally used in Korea.

  • PDF

수치 시뮬레이션을 이용한 수직밀폐형 지열시스템의 채열특성에 관한 연구 (Study on the characteristic of heat exchange for vertical geothermal system using the numerical simulation)

  • 남유진;오진환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.66-72
    • /
    • 2014
  • Ground source heat pump system can achieve high efficiency of performance by utilizing annually constant underground temperature to provide heat source for space heating and cooling. Generally, the depth of constant-temperature zone under the ground depends on surface heat flux and soil properties. The deeper the ground heat exchanger is installed, the higher the heat exchange rate can be acquired. However, in order to optimally design the system, it is necessary to consider both the installation cost and the system performance. In this study, performance analysis of ground source heat pump system according to the depth has been conducted through the case study.

철도차량용 공기청정시스템 개발 (Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

수소연료전지용 탄탈륨 탄화물에 대한 암모니아 분해반응 (Ammonia Decomposition Over Tantalum Carbides of Hydrogen Fuel Cell)

  • 최정길
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.51-59
    • /
    • 2013
  • Tantalum carbide crystallites which is to be used for $H_2$ fuel cell has been synthesized via a temperature-programmed reduction of $Ta_2O_5$ with pure $CH_4$. The resultant Ta carbide crystallites prepared using two different heating rates and space velocity exhibit the different surface areas. The $O_2$ uptake has a linear relation with surface area, corresponding to an oxygen capacity of $1.36{\times}10^{13}\;O\;cm^{-2}$. Tantalum carbide crystallites are very active for hydrogen production form ammonia decomposition reaction. Tantalum carbides are as much as two orders of magnitude more active than Pt/C catalyst (Engelhard). The highest activity has been observed at a ratio of $C_1/Ta^{{\delta}+}=0.85$, suggesting the presence of electron transfer between metals and carbon in metal carbides.