• Title/Summary/Keyword: heating space

Search Result 675, Processing Time 0.029 seconds

Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space (공조공간에서 수평토출형 에어커튼의 차단 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

Statistical Analysis of Supersonic Downflows in Sunspot Penumbrae

  • Kim, Hyunnam;Solanki, Sami K.;Lagg, Andreas;Kim, Kap-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.75.1-75.1
    • /
    • 2014
  • Sunspot penumbrae show supersonic downflow patches along the periphery. These patches are believed to be the return channels of the Evershed flow. There was previous study to investigate their structure in detail using Hinode SOT/SP observations (M. van Noort et al. 2013) but their data sample was only two sunspots. To make general description it needs to check more sunspot sample. We selected 242 downflow patches of 17 sunspots using Hinode SOT/SP observations from 2006 to 2012. Height-dependent maps of atmospheric parameters of these downflows was produced by using HeLix which was height dependent LTE inversion code of Stokes profiles. The inversion code at high resolution allows for the accurate determination of small scale structures. The recovered atmospheric structure of three layers indicates that regions with very high downflow velocities contain very strong magnetic fields reaching up to 7kG. The higher downflow velocity patches have bigger patch size. Magnetic fields of downflow patches are more vertical while penumbra shows horizontal field and neighbor of downflow patches have opposite polarity. Temperature of downflow patches at highest layer have more strong value than penumbra at deepest layer. The direction of velocity of downflow patches at highest layer have two branches. These result shows that we can expect some heating precess in the middle of layer.

  • PDF

Properties of the mini-halos in dwarf ellipticals obtained from cosmological hydrodynamic simulations

  • Shin, Jihye;Kim, Juhan;Kim, Sungsoo S.;Yoon, Suk-Jin;Park, Changbom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.77.1-77.1
    • /
    • 2012
  • We have performed cosmological hydrodynamic simulations that include the effects of radiative heating/cooling, star formation, feedback by supernova explosions, and metallicity evolution. Our simulations cover a cubic box of a side length 4 Mpc/h with 130 million particles. The mass of each particle is $3.4{\times}10^4M_{\odot}$, thus sub-galactic mini-halos can be resolved with more than hundred particles. Our simulation follows the whole formation process of the mini-halos (M< $10^7M_{\odot}$) around dwarf galaxies. We discuss various properties of the mini halos such as mass function, specific frequency, baryon-to-dark matter ratio, metallicity, spatial distribution, and orbit eccentricity distribution as functions of redshift and host galaxy mass. We also discuss how the formation and evolution of the mini halos are affected by the epoch of the reionization.

  • PDF

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Plan for the Development of a Standardized Dummy for Persons in Need of Rescue in a Confined Space (밀폐공간 구조 요구자를 위한 더미 표준화 개발 방안)

  • Choi, Seo-Yeon;Rie, Dong-Ho;Kim, Hyung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.99-105
    • /
    • 2016
  • This study was conducted to develop a dummy in an environment similar to the human body, to prepare a standard for evaluation and to present the process of the production in order to evaluate the performance of the robot that can detect the persons needing rescue in a confined space, who are difficult for fire-fighting officials to rescue in case of fire and disaster. As a result, a standard for evaluation was developed and standardized into four parts 'Normal,' 'Risk Stage 1,' 'Risk Stage 2' and 'Risk Stage 3'based on the number of breath cycles, carbon dioxide concentration, core temperature and criteria for hearing to recognize the voice. In addition, in order to produce a dummy, fever, breathing capacity and voice output function were compared and analyzed. This study has significance that it built up basic data of the method of producing the actual dummy, by presenting characteristics and controlling methods using the waterproof insulation heating coil for the function, solenoid valve for the consecutive output of breathing capacity and USB program sound board for voice output.

Radiative Transfer Modeling of EC 53: An Episodically Accreting Class I Young Stellar Object

  • Baek, Giseon;MacFarlane, Benjamin A.;Lee, Jeong-Eun;Stamatellos, Dimitris;Herczeg, Gregory;Johnstone, Doug;Chen, Huei-Ru Vivien;Kang, Sung-Ju
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.67.1-67.1
    • /
    • 2019
  • We present 2-dimensional continuum radiative transfer modeling for EC53. EC 53 is a Class I YSO, which was brightened at $850{\mu}m$ by a factor of 1.5. This luminosity variation was revealed by the JCMT Transient Survey. The increase in brightness is likely related to the enhanced accretion. We aim to investigate how much increase of protostellar luminosity causes the observed brightness increase at $850{\mu}m$. Thus we modeled the SED of EC 53 both in the quiescence and (small scale) outburst phases, with and without the external heating from the interstellar radiation field (ISRF). We found that the internal protostellar luminosity should increase more to fit the observed flux enhancement if the ISRF is considered in the model.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

THERMAL BALANCE MODELLING AND PREDICTION FOR A GEOSTATIONARY SATELLITE (정지궤도 위성의 열평형 시험 모델링 및 예비 예측)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.142-147
    • /
    • 2009
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be tested under vacuum condition and very low temperature in order to verify thermal design of COMS. The test will be performed by using KARI large thermal vacuum chamber, which was developed by KARI, and the COMS will be the first flight satellite tested in this chamber. The purposes of thermal balance test are to correlate analytical model used for design evaluation and predicting temperatures, and to verify and adjust thermal control concept. KARI has plan to use heating plates to simulate space hot condition especially for radiator panels such as north and south panels. They will be controlled from 90K to 273K by circulating GN2 and LN2 alternatively according to the test phases, while the shroud of the vacuum chamber will be under constant temperature, 90K, during all thermal balance test. This paper presents thermal modelling including test chamber, heating plates and the satellite without solar array wing and Ka-band reflectors and discusses temperature prediction during thermal balance test.

  • PDF

Physical Condition and User's Satisfaction on the Commom Public Areas of High School Dormitory in Local Area (지방 고등학교 기숙사의 공동생활공간에 대한 이용실태 및 사용자 만족도)

  • Choi, Byungsook;An, Jinsook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study was to analyze physical condition on the dormitory high school in Jeonju City, and find out users' satisfaction on that. This was going to contribute to the directions of it's physical environmental improvement. This was performed by a questionnaire survey method. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. Through analyzing those data about library, diningroom, laundry room, break room, computer room, restroom, shower room, hall lounge, and snack bar in a dormitory, the results are as follows. First, students thought some physical conditions to be inconvenient in an distracted study atmosphere and hard furniture of library, a bad location of diningroom, a short laundry machine, lack of tables in a break room, a short performance and supply computer, a small space and short toilet in restroom, and a short of hall lounge and snack bar. Second, the students' satisfaction of common public areas in dormitory was 3.39 score. Students were concerned with library and restroom shower room through analyzing satisfied and unsatisfied areas. Third, they needed to improve heating, cooling, and noise in common areas of dormitory, and needed to support a breakroom and snack bar. Conclusively, library, restroom shower room, break room, and snack bar were important common areas, and indoor environmental elements - heating, cooling and noise- were important in high school dormitory.

Failure and Deformation Characteristics of Rock at High and Low Temperatures (고온 및 저온하에서의 암석의 변형, 파괴 특성)

  • 정재훈;김영근;이형원;이희근
    • Tunnel and Underground Space
    • /
    • v.2 no.2
    • /
    • pp.224-236
    • /
    • 1992
  • It is very important to determine the thermo-mechanical characteristics of the rock mass surrounding the repository of radioctive waste and the LPG storage cavern. In this study, Hwasoon-Shist. Dado-Tuff adn Chunan-Tonalite were the selected rock types. Temperature dependence of the mechanical properteis such as uniaxial compressive strength, tensile strength, Young's modulus was investigated by measuring the behaviour of these properties due to the variation of temperature. Also, the characteristics of strength and deformation of these rocks were examined through high-temperature triaxial compression tests with varing temperatures and confining pressures. Important results obtained are as follows: In high temperature tests, the uniaxial compressive strength and Yong's modulus of Tonalite showed a sligth increase at a temperature up to 300$^{\circ}C$ and a sharp decrease beyond 300$^{\circ}C$, and the tensile strength showed a linear decrease with increasing heating-temperature. In high-temperature triaxial compression test, both the failure stress and Young's modulus of Tonalite increased with the increase of confining pressure at constant heating-temperature, and the failure stress decreased at 100$^{\circ}C$ but increased at 200$^{\circ}C$ under a constant confining pressure. In low temperature tests, the uniaxial compressive and tensile strengths and Young's modulus of these rocks increased as the cooling-temperature is reduced. Also, the uniaxial compressive and tensile strengths of wet rock specimens are less than those of dry rock specimens.

  • PDF